| Series | WRB_ST-1WR2 |
| Model | WRB2403ST/SD-1WR2 |
| Type | DC/DC Converters |
| Brand | MORNSUN |
| Input Current (full load/no-load) | 12VDC input voltage: 111/15 typ, 114/30 max mA; 24VDC input voltage: 55/6 typ, 57/10 max mA; 12VDC input voltage: 40mA |
| Reflected Ripple Current | 24VDC input voltage: 55; 12VDC input voltage: -0.7–25 |
| Surge Voltage (1sec. max.) | 24VDC input voltage: -0.7–50 VDC; 12VDC input voltage: 9 VDC |
| Start-up Voltage | 18 @24VDC input voltage |
| Input Filter | Capacitance filter |
| Hot Plug | Unavailable |
| Output Voltage Accuracy | 5%-100% load, input voltage range: ±1 typ, ±3 max; 3.3VDC output: ±5 typ, ±7 max |
| No-load Output Voltage Accuracy | Input voltage range: %; Others: ±1.5% typ, ±5% max |
| Linear Regulation | ±0.2 typ, ±0.5 max (Input voltage variation from low to high at full) (load) |
| Load Regulation | ±0.5% typ, ±1% max (5%-100% load) |
| Transient Recovery Time | 1 ms typ, 3 ms max; 25% load step change: ms |
| Transient Response Deviation | ±2.5% typ, ±5% max |
| Temperature Coefficient | ±0.03%/℃ (Full load) |
| Short-circuit Protection | Continuous, self-recovery |
| Isolation (Input–Output) | VDC (Electric Strength test for 1 minute) |
| Isolation | 1500 VDC |
| Insulation Resistance | Input-output insulation at 500VDC: 1000 MΩ |
| Isolation Capacitance | 100 pF (Input-output capacitance at 100KHz/0.1V) |
| Operating Temperature | -40 to +85℃ (See Fig. 1) |
| Storage Temperature | -55–+125℃ (Soldering spot is 1.5mm away from case for 10) |
| Case Material | Black flame-retardant and heat-resistant plastic; WRB_SD-1WR2: 14.00 × 14.00 × 9.00 mm |
| Dimension | WRB_ST-1WR2: 15.00 × 14.00 × 9.10 mm |
| Weight | 2.2g (Typ.) |
| Cooling Method | Free air convection |
| EMC Emissions | CE: CISPR32/EN55032 CLASS B (see Fig. 3-② for recommended circuit); RE: CISPR32/EN55032 CLASS B (see Fig. 3-② for recommended circuit) |
| EMC Immunity | ESD: IEC/EN61000-4-2 Contact ±6KV (perf. Criteria B); RS: IEC/EN61000-4-3 10V/m (perf. Criteria A); EFT: IEC/EN61000-4-4 ±2KV (see Fig. 3-① for recommended circuit) (perf. Criteria B); Surge: IEC/EN61000-4-5 line to line ±2KV (see Fig. 3-① for recommended circuit) (perf. Criteria B); CS: IEC/EN61000-4-6 3 Vr.m.s (perf. Criteria A) |