| Series | URB48_LD-60W(H)R3 |
| Model | URB4824LD-60W(H)R3 |
| Type | DC/DC Converters |
| Brand | MORNSUN |
| Input Current (full load / no-load) | 1345/10 typ, 1389/15 max mA (Nominal input voltage) |
| Surge Voltage (1sec. max.) | -0.7–100 VDC |
| Start-up Voltage | 18 |
| Input Filter | PI filter |
| Hot Plug | Unavailable (3-12VDC); Module on: Ctrl pin open or pulled high TTL (3-12VDC) |
| Ctrl | Ctrl pin pulled low to GND (0-1.2VDC) (Module off) |
| Output Voltage Accuracy | 5%-100% load: ±1 typ, ±2 max; 0%-5% load: ±2 typ, ±5 max |
| Linear Regulation | ±0.2% typ, ±0.5% max (Input voltage variation from low to high at full load) |
| Load Regulation | 5%-100% load: ±0.5 typ, ±1 max; 25% load step change, 5V output: ±3 typ, ±10 max |
| Transient Response Deviation | ±3 typ, ±5 max (input voltage range Other output) |
| Transient Recovery Time | 25% load step change, nominal input voltage: 250 µs typ, 500 µs max; 5%-100% load: 100mVp-p (20MHz bandwidth) |
| Ripple & Noise ① | 5 %Vo max (nominal input voltage 0%-5% load) |
| Over-voltage Protection | 110–160 %Vo |
| Over-current Protection | 110–200 %Io (Input voltage range) |
| Short-circuit Protection | Continuous, self-recovery |
| Isolation (Input–Output) | VDC (Electric Strength Test for 1 minute with) |
| Isolation | 1600 VDC |
| Insulation Resistance | Input-output resistance at 500VDC: 100 MΩ |
| Isolation Capacitance | 2200 pF (Input-output capacitance at 100kHz/0.1V) |
| Operating Temperature | -40 to +105℃ (See Fig. 1) |
| Storage Temperature | -55–+125℃ |
| Storage Humidity | Non-condensing: 5–95 %RH; Soldering spot is 1.5mm away from case for 10: %RH; 300 %RH |
| Case Material | Aluminum alloy; Horizontal package: 50.80 × 25.40 × 11.80 mm; Without heat sink A2S chassis mounting 76.00*31.50*: 21.20 mm |
| Dimensions | A4S Din-rail mounting 76.00*31.50*: 25.80 mm; Heat sink Horizontal package: 51.40 x 26.20 x 16.50 mm; Horizontal package: 40.0g |
| Weight | Without heat sink A2S chassis mounting: 63.0g; A4S Din-rail mounting: 83.0g; Heat sink: 49.8g |
| Cooling Method | Free air convection |
| EMC Emissions | ; |
| EMC Immunity | ESD: IEC/EN61000-4-2 Contact ±6kV (perf. Criteria B); RS: IEC/EN61000-4-3 10V/m (perf. Criteria A); EFT: IEC/EN61000-4-4 100kHz ±2kV (see Fig. 3-② for recommended circuit) (perf. Criteria A); Surge: IEC/EN61000-4-5 line to line ±2kV (see Fig. 3-② for recommended circuit) (perf. Criteria A); CS: IEC/EN61000-4-6 10 Vr.m.s (perf. Criteria A) |