| Series | URB24_LD-40W(H)R3 |
| Model | URB2405LD-40W(H)R3 |
| Type | DC/DC Converters |
| Brand | MORNSUN |
| Input Current (full load / no-load) | 5V output: 1831/15 typ, 1872/30 max mA; Nominal input voltage 12V/24V output: 1811/15 typ, 1851/30 max mA; 15V output: 1972/15 typ, 1831/30 max mA |
| Reflected Ripple Current | 40 max (Nominal input voltage, 100% load) |
| Surge Voltage (1sec. max.) | -0.7–50 VDC |
| Start-up Voltage | 9 |
| Input Filter | PI filter |
| Hot Plug | Unavailable (3-12VDC); Module on: Ctrl pin open or pulled high TTL (3-12VDC) |
| Ctrl | Module off: Ctrl pin pulled low to GND (0-1.2VDC) 12; Input current when off: 6 12 |
| Output Voltage Accuracy | 5%-100% load: ±1% typ, ±2% max; 0%-5% load: ±2% typ, ±5% max |
| Linear Regulation | ±0.2 typ, ±0.5 max (Input voltage variation from low to high at full load) |
| Load Regulation | ±0.5 typ, ±1 max (5%-100% load) |
| Transient Response Deviation | ±3% typ, ±10% max (25% load step change, input 5V output) |
| Transient Recovery Time | 250 µs typ, 500 µs max (25% load step change, nominal input voltage) |
| Temperature Coefficient | Full load: ±0.03%/℃; 5%-100% load: 100 mV p-p typ, 200 mV p-p max (20MHz bandwidth) |
| Ripple & Noise ① | 5V output: 5 %Vo max; %Vo; Other output: 3 %Vo max (20MHz bandwidth) |
| Over-voltage Protection | 110–160 %Vo |
| Over-current Protection | 110–200 %Io (Input voltage range) |
| Short-circuit Protection | Continuous, self-recovery |
| Isolation (Input–Output) | VDC (Electric Strength Test for 1 minute with) |
| Isolation | 1500 VDC |
| Insulation Resistance | Input-output resistance at 500VDC: 100 MΩ |
| Isolation Capacitance | 1400 pF (Input-output capacitance at 100KHz/0.1V) |
| Operating Temperature | -40 to +105℃ (See Fig. 1) |
| Storage Temperature | -55–+125℃ |
| Storage Humidity | 5–95 %RH (Non-condensing) |
| Case Material | Aluminum alloy; Without heat sink: 50.80 × 25.40 × 11.80 mm |
| Dimensions | Heat sink: 51.40 x 26.20 x 16.50 mm; Without heat sink: 41.0g(Typ.) |
| Weight | Heat sink: 50.8g(Typ.) |
| Cooling Method | Free air convection |
| EMC Emissions | ; RE: CISPR32/EN55032 |
| EMC Immunity | ESD: IEC/EN61000-4-2 Contact ±6KV (perf. Criteria B); RS: IEC/EN61000-4-3 10V/m (perf. Criteria A); EFT: IEC/EN61000-4-4 (Vout=12/15V see Fig. 3-② for recommended circuit, (perf. Criteria A); Surge: IEC/EN61000-4-5 (Vout=12/15V see Fig. 3-② for recommended circuit, (perf. Criteria A); CS: IEC/EN61000-4-6 10 Vr.m.s (perf. Criteria A) |