| Series | vrb_jd-3w |
| Model | URB2403JM-3W |
| Type | DC/DC Converters |
| Brand | MORNSUN |
| Input Current (full load / no-load) | 5VDC input: 833/20 typ, 857/45 max mA; Nominal input voltage: mA; 24VDC input: 164/4 typ, 169/15 max mA |
| Reflected Ripple Current | Nominal input voltage: 100; 5VDC input: -0.7–16 |
| Surge Voltage (1sec. max.) | 24VDC input: -0.7–50 VDC; VRB05xxJ(M)D/T-3W series: 4.5 VDC |
| Start-up Voltage | URB24XXJ(M)D/T-3W series: 9; VRB05xxJ(M)D/T-3W series: 2.5 |
| Shut-down Voltage | URB24XXJ(M)D/T-3W series: 5.5; VRB05xxJ(M)D/T-3W series: LC filter |
| Input Filter | C typ, filter max (URB24XXJ(M)D/T-3W series) |
| Hot Plug | Unavailable (0-0.3VDC); Module on: Ctrl pin open or pulled low (0-0.3VDC) |
| Ctrl | Module off: Ctrl pin pulled high (2-12VDC) mA; Input current when switched off: 5mA typ, 10mA max |
| Output Voltage Accuracy | ±1 typ, ±2 max (0% -100% load) |
| Linear Regulation | ±0.2% typ, ±0.5% max (Input voltage variation from low to high at full load) |
| Load Regulation ① | ±1% (5% -100% load) |
| Transient Recovery Time | 25% load step change, nominal input voltage: 300 µs typ, 500 µs max; 3.3 VDC output: ±5 µs typ, ±10 µs max |
| Transient Response Deviation | 25% load step change, nominal input voltage 5 VDC output: ±5% typ, ±8% max; others output: ±3% typ, ±5% max |
| Temperature Coefficient | ±0.03%/℃ (Full load) |
| Ripple & Noise ② | 50mVp-p typ, 100mVp-p max (5% -100% load) (20MHz bandwidth) |
| Trim | ±5 %Vo |
| Over-voltage Protection | 110–160 %Vo |
| Over-current Protection | 110–250 %Io (Input voltage range) |
| Short-circuit Protection | Hiccup, continuous, self-recovery |
| Case Material | Only for U/VRB_JMD/JMT-3W series products Aluminum alloy; JD series: 24.00 x 15.10 x 6.19 mm; JT series: 26.20 x 15.10 x 6.19 mm |
| Dimensions | JMD series: 25.00 x 16.40 x 6.80 mm; JMT series: 26.20 x 16.40 x 6.80 mm; JD/JT series: 2.2g (Typ.) |
| Weight | JMD/JMT series: 3.5g (Typ.) |
| Cooling method | Free air convection(20LFM) |
| Electromagnetic | compatibility (EMC) |
| CE | CISPR32/EN55032 CLASS B (see Fig.3-② for recommended circuit) |
| RE | CISPR32/EN55032 CLASS B (see Fig.3-② for recommended circuit) |
| ESD | IEC/EN61000-4-2 Contact ±6kV perf. Criteria B |
| RS | IEC/EN61000-4-3 10V/m perf. Criteria A |
| Immunity EFT | IEC/EN61000-4-4 ±2kV (see Fig.3-① for recommended circuit) perf. Criteria B |
| Surge | IEC/EN61000-4-5 line to line ±2kV (see Fig.3-① for recommended circuit) perf. Criteria B |
| CS | IEC/EN61000-4-6 3 Vr.m.s perf. Criteria A |