| Series | CUWB_YMD-6WR3 |
| Model | CUWB1212YMD-6WR3 |
| Type | DC/DC Converters |
| Brand | MORNSUN |
| Input Current (full load / no-load) | 3.3V output: 522/5 typ, 536/12 max mA; 12VDC nominal input series,: mA; 5V, 12V, 15V output: 602/5 typ, 617/12 max mA; nominal input voltage: mA; 24V output: 588/10 typ, 602/15 max mA |
| Reflected Ripple Current | 20 (Nominal input voltage) |
| Surge Voltage (1sec. max.) | -0.7–50 @12VDC nominal input series |
| Start-up Voltage | 4.5 VDC @12VDC nominal input series |
| Input Under-voltage Protection | 3.5 typ, 3 min @12VDC nominal input series |
| Input Filter | Pi filter |
| Hot Plug | Unavailable |
| Output Voltage Accuracy | ±1 typ, ±2 max (0% -100% load) |
| Linear Regulation | ±0.2% typ, ±0.5% max (Input voltage variation from low to high at full load) |
| Load Regulation ① | ±0.5 typ, ±1 max (5% -100% load) |
| Transient Recovery Time | 300 µs typ, 500 µs max; 25% load step change, 3.3V/ 5V output: ±5 µs typ, ±8 µs max |
| Transient Response Deviation | nominal input voltage: %; Others: ±3% typ, ±5% max |
| Temperature Coefficient | ±0.03%/℃ (Full load) |
| Ripple & Noise ② | 60 mV p-p typ, 85 mV p-p max (5% -100% load) (20MHz bandwidth) |
| Over-voltage Protection | Input voltage range: 110–160 %Vo; 4.5≤Vin<24: 110–260 %Vo |
| Over-current Protection ③ | Input voltage range: %Io; 24≤Vin≤36: 190–300 %Io |
| Short-circuit Protection | Continuous, self-recovery (Input voltage range) |
| Case Material | Aluminum alloy |
| Dimensions | 25.40 x 25.40 x 11.70 mm |
| Weight | 14.0g (Typ.) |
| Cooling method | Free air convection |
| EMC Emissions | ; |
| EMC Immunity | ESD: IEC/EN61000-4-2 Contact ±4kV (perf. Criteria B); RS: IEC/EN61000-4-3 10V/m (perf. Criteria A); EFT: IEC/EN61000-4-4 ±2kV (see Fig.3-① for recommended circuit) (perf. Criteria B); Surge: IEC/EN61000-4-5 line to line ±2kV (see Fig.3-①for recommended circuit) (perf. Criteria B); CS: IEC/EN61000-4-6 10 Vr.m.s (perf. Criteria A) |