| Series | LS10-13BxxR3 |
| Model | LS10-13B24R3 |
| Brand | MORNSUN |
| Input Voltage Range (AC) | 85–305 VAC |
| Input Voltage Range (DC) | 100–430 VDC |
| Input Frequency | 47–63 Hz; 115VAC: 0.30 Hz |
| Input Current | 230VAC: 0.18A max; 115VAC: 15A |
| Inrush Current | 277VAC: 30A; 1A, slow-blow, required |
| Recommended External Input Fuse | (The actual use needs to be selected; according to the application environment) |
| Hot Plug | Unavailable |
| Output Voltage Accuracy | 3.3V: ±3%; 5V/9V/12V/15V/24V: ±2% |
| Line Regulation | ±1% (Rated load) |
| Load Regulation | ±1.5% (0% - 100% load) |
| Minimum Load | 0 |
| Ripple & Noise | 80mV typ, 150mV max ((peak-to-peak value)) (20MHz bandwidth) |
| Temperature Coefficient | ±0.02%/℃; 3.3V/5V: 0.05 %/℃ typ, 0.10 %/℃ max |
| Stand-by Power Consumption | 230VAC 9V/12V/15V: 0.09W typ, 0.12W max; 24V: 0.13W typ, 0.15W max |
| Short Circuit Protection | Hiccup, continuous, self-recover |
| Over-current Protection | ≥110% Io, self-recover hiccup); 3.3/5VDC output: ≤9VDC (Output voltage clamp or hiccup); 9VDC output: ≤15VDC (Output voltage clamp or hiccup) |
| Over-voltage Protection | 12VDC output: ≤16VDC (Output voltage clamp or hiccup); 15VDC output: ≤21VDC (Output voltage clamp or hiccup); 24VDC output: ≤32VDC (Output voltage clamp or hiccup) |
| Isolation Input-output | Electric Strength Test for 1min.,: 3600 VAC; leakage current<5mA: 5000 VDC |
| Operating Temperature | -40 to +85℃ |
| Storage Temperature | -40–+105℃ |
| Storage Humidity | 95 %RH; Wave-soldering: 260 ± 5℃; typ, time: 5 - 10s max %RH |
| Soldering Temperature | Manual-welding: 360 ± 10℃; typ, time: 3 - 5s max %/℃; +55℃ to +85℃: 2.5 %/℃ |
| Power Derating | 85VAC - 100VAC: 1 %/VAC; 277AVC - 305VAC: 0.54 %/VAC; IEC/BS EN/EN62368-1, GB4943.1 safety %/VAC |
| Safety Standard | approved; design refer to UL62368-1; IEC/EN60335-1 typ; IEC/EN61558-1; min |
| Safety Class | CLASS II |
| MTBF | ≥1000,000 h (MIL-HDBK-217F@25℃) |
| Dimension | 32.00 x 17.20 x 15.05 mm |
| Weight | 8.2g (Typ.) |
| Cooling method | Free air convection |
| EMC Emissions | ; |
| EMC Immunity | ESD: IEC/EN61000-4-2 Contact ±6KV (perf. Criteria B); RS: IEC/EN61000-4-3 10V/m (perf. Criteria A); ; ; CS: IEC/EN61000-4-6 10Vr.m.s (perf. Criteria A); |