| Series | LO15-10Bxx |
| Model | LO15-10B24 |
| Brand | MORNSUN |
| Input Voltage Range (AC) | 85–264 VAC |
| Input Voltage Range (DC) | 100–370 VDC |
| Input Frequency | 47–63 Hz; 115VAC: 0.37 Hz |
| Input Current | 230VAC: 0.22A max; 115VAC: 20A |
| Inrush Current | 30A @230VAC |
| Leakage Current | 0.25mA typ, RMS max. max @264VAC |
| Hot Plug | Unavailable |
| Output Voltage Accuracy | 3.3V output: ±3%; Other output: ±2% |
| Line Regulation | ±0.5% (Full load) |
| Load Regulation | ±1% (0%-100% load) |
| Ripple & Noise | 50mV typ, 100mV max ((peak-to-peak value)) (20MHz bandwidth) |
| Temperature Coefficient | ±0.02%/℃ |
| Stand-by Power Consumption | 0.5W |
| Short Circuit Protection | Hiccup, continuous, self-recovery; 3.3/5V output: ≤7.5V; 9V output: ≤15V |
| Over-voltage Protection | Output voltage clamp or hiccup; 12/15V output: ≤20V; 24V output: ≤30V |
| Over-current Protection | ≥130%Io, typ, self-recovery max |
| Minimum Load | 0% |
| Start-up Time | 85VAC-264VAC input, Io=100%: 2000 ms; 115VAC input, Io=100%: 10 ms |
| Hold-up Time | 60 @230VAC input, Io=100% |
| Isolation | VAC (Electric Strength Test for 1min.,) |
| Isolation (Input–Output) | 3000 VAC |
| Operating Temperature | -25 to +70℃ |
| Storage Temperature | -25–+85℃ |
| Storage Humidity | 90 %RH |
| Altitude | 2000 m; Wave-soldering: 260 ± 5℃; typ, time: 5 -10s max |
| Soldering Temperature | Manual-welding: 360 ±10℃; typ, time: 3 - 5s max %/℃; -25℃ to -10℃: 1 %/℃ |
| Power Derating | +50℃ to +70℃: 3; 85VAC - 100VAC: 1.67 %/VAC; Design refer to UL/IEC62368-1 & EN62368-1, |
| Safety Standard | UL/EN60335-1 typ; BS EN62368-1; min |
| Safety Class | CLASS I I |
| MTBF | > 300,000 h (MIL-HDBK-217F@25℃) |
| Dimension | 63.50 x 45.70 x 19.00mm |
| Weight | 36g (Typ.) |
| Cooling Method | Free air convection |
| EMC Emissions | CE: CISPR32/EN55032 CLASS B; RE: CISPR32/EN55032 CLASS B |
| EMC Immunity | ESD: IEC/EN61000-4-2 Contact ±6KV (Perf. Criteria B); RS: IEC/EN61000-4-3 10V/m (Perf. Criteria A); EFT: IEC/EN61000-4-4 ±2KV (Perf. Criteria B); Surge: IEC/EN61000-4-5 Line to line ±1KV; CS: IEC/EN61000-4-6 10Vr.m.s (Perf. Criteria A); Voltage dips, short: interruptions and IEC/EN61000-4-11 100% dip 1 periods, 30% dip 25 periods, |