| Series | LDE03-20BxxW |
| Model | LDE03-20BxxW |
| Brand | MORNSUN |
| Input Voltage Range (AC) | 85–264 VAC |
| Input Voltage Range (DC) | 100–370 VDC |
| Input frequency | 47–63 Hz; 115VAC: 80 Hz; LDE03: Hz; 230VAC: 45 Hz |
| Input current | mA; 115VAC: 130mA; LDE05: mA; 230VAC: 70mA; 115VAC: 10mA |
| Inrush current | A; 230VAC: 20A |
| Leakage current | 0.1mA typ, RMS typ. max @230VAC/50Hz |
| Recommended External Input Fuse | 1A/250V, slow-blow, required |
| Hot Plug | Unavailable |
| Output Voltage Accuracy | 3.3V output: ±3%; The others: ±2% |
| Line Regulation | ±0.5% (Full load) |
| Load Regulation | ±1% (0%-100% load) |
| Ripple & Noise | 50mV typ, 100mV max ((peak-to-peak value)) (20MHz bandwidth) |
| Temperature Drift Coefficient | ±0.02%/°C |
| Short Circuit Protection | Hiccup, continuous, self-recover; LDE03: ≥150% Io self-recover |
| Over-current Protection | LDE05: ≥120% Io self-recover; 3.3/5VDC output: ≤7.5VDC; 9VDC output: ≤15VDC |
| Over-voltage Protection | 12/15VDC output: ≤20VDC; 24VDC output: ≤30VDC |
| Minimum Load | 0%; 115VAC input: 10%; LDE03: %; 230VAC input: 60% |
| Power-off Holding Time | ms; 115VAC input: 5 ms; LDE05: ms; 230VAC input: 50 ms |
| Isolation Input-output | Electric Strength Test for 1min.,: VAC; 4000 VAC; (leakage current<5mA): VAC |
| Operating Temperature | -40 to +70℃ |
| Storage Temperature | -40–+105℃ |
| Storage Humidity | 95 %RH; Wave-soldering, Max. 10 seconds: 255–265 %RH |
| Soldering Temperature | ℃; Manual-welding, Max. 5 seconds: 350 to 370℃ |
| Switching Frequency | 100kHz; -40℃ to -25℃: 1.0; +55℃ to +70℃: 1.0 %/℃ (LDE03) |
| Power Derating | -40℃ to 0℃: 1.13 %/VAC; LDE05: %/VAC; +55℃ to +70℃: 3.0 %/VAC; LDE05 85 - 100VAC: 1.0 %/VAC; IEC62368-1 safety approved & %/VAC |
| Safety Standard | EN/BS EN62368-1(Report); Design refer to UL62368-1 |
| Safety Class | CLASS Ⅱ |
| MTBF | MIL-HDBK-217F@25℃–300,000 h |
| Case Material | Black plastic, flame-retardant and heat-resistant (UL94V-0) |
| Package Dimensions | 37.0 x 24.5 x 18.0 mm |
| Weight | 30g (Typ.) |
| Cooling method | Free air convection |
| EMC Emissions | ; |
| EMC Immunity | ESD: IEC/EN61000-4-2 Contact ±6 KV/Air ±8 KV (perf. Criteria B); RS: IEC/EN61000-4-3 10V/m (perf. Criteria A); ; ; CS: IEC/EN61000-4-6 10Vr.m.s (perf. Criteria A); |