| Series | LO45-10Cxx |
| Model | LO45-10C051212-20 |
| Brand | MORNSUN |
| Input Voltage Range (AC) | 85–264 VAC |
| Input Voltage Range (DC) | 100–370 VDC |
| Input Frequency | 47–63 Hz; 115VAC: 1.2 Hz |
| Input Current | 230VAC: 0.7A max; 115VAC: 35A |
| Inrush Current | 50A @230VAC |
| Leakage Current | 0.5mA typ, Max. max @240VAC/50Hz |
| Hot Plug | Unavailable |
| Output Voltage Accuracy | Vo1: ±2%; Vo2, -Vo3: ±10%; Vo1: ±0.5% |
| Line Regulation | %; Vo2, -Vo3: ±1.5%; Vo1: ±2% |
| Load Regulation | Vo2, -Vo3: ±5%; Vo1: 120% (Balanced load; 20MHz bandwidth) |
| Ripple & Noise | mV; room temperature Vo2, -Vo3: 200mV max ((peak-to-peak value)) |
| Stand-by Power Consumption | 0.5W @230VAC |
| Temperature Coefficient | ±0.02%/℃ (Vo1) |
| Short Circuit Protection | Hiccup or turn off, continuous, self-recovery |
| Over-current Protection | ≥120%Io, typ, self-recovery max |
| Over-voltage Protection | ≤7.5V (Output voltage hiccup clamp or turn off) @5VDC output |
| Minimum Load | 10%; 115VAC input: 8% |
| Hold-up Time | ms; 230VAC input: 50 ms |
| Isolation | VAC (Electric Strength Test for 1min., leakage current) |
| Isolation (Input–Output) | 3000 VAC |
| Operating Temperature | -25 to +70℃ |
| Storage Temperature | -25–+85℃ |
| Storage Humidity | 90 %RH |
| Altitude | 2000 m |
| Switching Frequency | 65kHz; -25℃ to -10℃: 2.0 %/℃; +50℃ to +70℃: 2.5 |
| Power Derating | 85VAC-165VAC: 0.375 %/VAC; 240VAC-264VAC: 0.833 %/VAC; EN62368-1, BS EN62368-1 (Report); %/VAC |
| Safety Standard | Design refer to UL/IEC62368-1 |
| Safety Class | CLASS Ⅱ |
| MTBF | >300,000 typ, MIL-HDBK-217F@25℃ min h |
| Dimension | 102.00 x 51.00 x 30.00 mm |
| Weight | 105g (Typ.) |
| Cooling Method | Free air convection |
| EMC Emissions | CE: CISPR32/EN55032 CLASS B; RE: CISPR32/EN55032 CLASS B |
| EMC Immunity | ESD: IEC/EN61000-4-2 Contact ±6KV (Perf. Criteria B); RS: IEC/EN61000-4-3 10V/m (Perf. Criteria A); EFT: IEC/EN61000-4-4 ±2KV (Perf. Criteria B); ; CS: IEC/EN61000-4-6 10Vr.m.s (Perf. Criteria A); Voltage dips,: short interruption and IEC/EN61000-4-11 100% dip 1 periods, 30% dip 25 (periods,) |