| Series | LD10-23BxxR2 |
| Model | LD10-23B24R2 |
| Brand | MORNSUN |
| Input Voltage Range (AC) | 85–305 VAC |
| Input Voltage Range (DC) | 100–430 VDC |
| Input Frequency | 47–63 Hz; 115VAC: 0.23 Hz |
| Input Current | 230VAC: 0.15A max; 115VAC: 25A |
| Inrush Current | 40A @230VAC |
| Leakage Current | 0.1mA typ, RMS Max. max @277VAC/50Hz |
| Fuse (A2S/A4S package series | 2A/300V, slow-blow, required |
| Hot Plug | Unavailable |
| Output Voltage Accuracy | ±2% (Full load range) |
| Line Regulation | ±0.5% (Rated load) |
| Load Regulation | ±1% (0%-100% load) |
| Ripple & Noise | (peak-to-peak value): 50mV typ, 100mV max; 3.3/5/9/12/15V: 0.10mV (20MHz bandwidth) |
| Stand-by Power Consumption | 230VAC: W; 24V: 0.12W |
| Temperature Coefficient | ±0.02%/℃ |
| Short Circuit Protection | Hiccup, continuous, self-recover |
| Over-current Protection | ≥110%Io, typ, self-recover max; 3.3/5V: ≤7.5VDC (Output voltage clamp or hiccup ); 9V: ≤15VDC (Output voltage clamp or hiccup ) |
| Over-voltage Protection | 12/15V: ≤20VDC (Output voltage clamp or hiccup ); 24V: ≤30VDC (Output voltage clamp or hiccup ) |
| Minimum Load | 0%; 115VAC: 8% |
| Hold-up Time | ms; 230VAC: 40 ms |
| Isolation Input-output | 4200 VAC (Electric Strength Test for 1min., leakage current <5mA) |
| Insulation Input-output Resistance | 100 MΩ @At 500VDC |
| Operating Temperature | -40 to +85℃ |
| Storage Temperature | -40–+85℃ |
| Storage Humidity | 95 %RH; Wave-soldering, Max. 10 seconds: 255–265 %RH |
| Soldering Temperature | ℃; Manual-welding, Max. 5 seconds: 350 to 370℃ |
| Switching Frequency | 65kHz; -40℃ to -25℃ 85VAC - 115VAC: 2.2; +50℃ to +70℃ 3.3/5V: 2.5 %/℃; +55℃ to +70℃ 9/12/15/24V: 3.33 |
| Power Derating | +70℃ to +85℃: 0.66; 85VAC - 115VAC: 0.83 %/VAC; 2000m - 5000m: 6.7 %/km; IEC62368-1,–GB4943.1 safety; approval &–EN60335-1,; BS EN/EN62368-1 (Report); (LD10-23B12R2A2S, LD10-23B12R2A4S) |
| Safety Standard | Design refer to UL62368-1 &; IEC62368-1; IEC61558-1 safety approval &; EN61558-2-16; –BS EN/EN62368-1 &; (Report) and design refer to UL62368-1 & |
| Safety Class | CLASS I I |
| MTBF | MIL-HDBK-217F@25℃: >3,200,000 h; Ta: 25℃ 100% load: >130x10 3 h |
| Designed life | 230VAC Ta: 55℃ 100% load: >20x10 3 h; Ta: 55℃ 80% load: >27x10 3 h |
| Case Material | Black plastic, flame-retardant and heat-resistant (UL94V-0); DIP package: 40.00 x 25.40 x 21.00 mm |
| Dimension | A2S chassis mounting: 76.00 x 31.50 x 29.80 mm; A4S Din-Rail mounting: 76.00 x 31.50 x 34.40 mm; DIP mounting: 34g (Typ.) |
| Weight | A2S chassis mounting: 54g (Typ.); A4S Din-Rail mounting: 74g (Typ.) |
| Cooling method | Free air convection |
| EMC Emissions | ; |
| EMC Immunity | ; ; ; Surge: IEC/EN61000-4-5 line to line ±2KV/line to PE ±4KV; ; Voltage dip,: short IEC/EN61000-4-11 0%, 70% (perf. Criteria B) |