| Series | LO10-13Bxx |
| Model | LO10-13B24 |
| Brand | MORNSUN |
| Input Voltage Range (AC) | 85–305 VAC |
| Input Voltage Range (DC) | 100–430 VDC |
| Input Frequency | 47–60 Hz; 115VAC: 0.23 Hz |
| Input Current | 230VAC: 0.15A max; 115VAC: 20A |
| Inrush Current | 40A @230VAC |
| Leakage current | 0.25mA typ, RMS max. max @305VAC |
| Hot Plug | Unavailable |
| Output Voltage Accuracy | 3.3V output: ±3%; Other output: ±2% |
| Line Regulation | ±0.5% (Full load) |
| Load Regulation | ±1% (0%-100% load) |
| Ripple & Noise | 100mV max ((peak-to-peak value)) (20MHz bandwidth) |
| Temperature Coefficient | ±0.02%/℃; 3.3V/5V/9V: 0.3% W |
| Stand-by Power Consumption | 0.5W (12V/15V/24V) |
| Short Circuit Protection | Hiccup, continuous, self-recovery; 3.3/5V output: ≤7.5V; 9V output: ≤15V |
| Over-voltage Protection | Output voltage clamp or hiccup; 12/15V output: ≤20V; 24V output: ≤30V |
| Over-current Protection | ≥110%Io, Hiccup, self-recovery |
| Minimum Load | 0%; 115VAC input, Io=100%: 8% |
| Hold-up Time | 75 @230VAC input, Io=100% |
| Isolation Input-output | Electric Strength Test for 1min.,: VAC; 3000 VAC; (leakage current<5mA): VAC |
| Operating Temperature | -25 to +70℃ |
| Storage Temperature | -25–+85℃ |
| Storage Humidity | 90 %RH (Non-condensing) |
| Altitude | 2000 m; -25℃ to -10℃: 1 %/℃; +50℃ to +70℃: 2.5 |
| Power Derating | 85VAC - 100VAC: 1.67 %/VAC; 277VAC-305VAC: 0.715 %/VAC; (Report); typ, EN62368-1 min %/VAC |
| Safety Standard | Design refer to UL/IEC62368-1 & UL/EN60335-1 |
| Safety Class | CLASS I I |
| MTBF | MIL-HDBK-217F@25℃–300,000 h |
| Dimension | 60.00 x 42.00 x 18.80 mm |
| Weight | 34g (Typ.) |
| Cooling Method | Free air convection |
| EMC Emissions | CE: CISPR32/EN55032 CLASS B; RE: CISPR32/EN55032 CLASS B |
| EMC Immunity | ESD: IEC/EN 61000-4-2 Contact ±6KV (Perf. Criteria B); RS: IEC/EN 61000-4-3 10V/m (Perf. Criteria A); EFT: IEC/EN 61000-4-4 ±2KV (Perf. Criteria B); Surge: IEC/EN 61000-4-5 line to line ±1KV (Perf. Criteria B); CS: IEC/EN 61000-4-6 10Vr.m.s (Perf. Criteria A); Voltage Variations: * IEC/EN 61000-4-11 0% U , 1 cycle; (Perf. Criteria B) |