| Serie | LD03-20Bxx-C |
| Modell | LD03-20Bxx-C |
| Marke | MORNSUN |
| Eingangsspannungsbereich (AC) | 85–264 VAC |
| Eingangsspannungsbereich (DC) | 100–370 VDC |
| Input frequency | 47–63 Hz; 115VAC: 80 Hz; LD03: Hz; 230VAC: 50 Hz |
| Input current | mA; 115VAC: 130mA; LD05: mA; 230VAC: 80mA; 115VAC: 10mA |
| Inrush current | A; 230VAC: 20A |
| Leakage current | 0.1mA typ, RMS typ. max @230VAC/50Hz |
| Recommended External Input Fuse | 1A/250V, slow-blow, required |
| Hot-Plug | Unavailable |
| Ausgangsspannungsgenauigkeit | 3.3V output: ±3%; Others: ±2% |
| Netzregelung | ±0.5% (Full load) |
| Lastregelung | ±1% (0%-100% load) |
| Restwelligkeit und Rauschen | 50mV typ, 100mV max ((peak-peak value)) (20MHz bandwidth) |
| Temperaturdriftkoeffizient | ±0.02%/°C |
| Kurzschlussschutz | Continuous, self-recovery; LD03: ≥150% Io self-recovery |
| Überstromschutz | LD05: ≥120% Io self-recovery; 3.3/5VDC output: ≤7.5VDC |
| Überspannungsschutz | 9VDC output: ≤15VDC; 12/15VDC output: ≤20VDC |
| Min. Load | 0%; 115VAC input: 10%; LD03: %; 230VAC input: 60% |
| Power-off Holding Time | ms; 115VAC input: 5 ms; LD05: ms; 230VAC input: 50 ms |
| Isolation Voltage Input-output | 4000 VAC (Test time: 1min(leakage current setting value:5 mA)) |
| Betriebstemperatur | -40 to +70°C |
| Lagertemperatur | -40–+105℃ |
| Lagerfeuchtigkeit | 95 %RH; Wave-soldering: 260 ± 5℃; typ, time: 5 - 10s max %RH |
| Welding Temperature | 360 ± 10℃; typ, time: 3 - 5s max (Manual-welding) |
| Schaltfrequenz | 100kHz; -40℃ to -25℃: 1.0; +55℃ to +70℃: 1.0 %/°C (LD03) |
| Power Derating | -40℃ to 0℃: 1.13 %/VAC; LD05: %/VAC; +55℃ to +70℃: 3.0 %/VAC; LD05 85 - 100VAC: 1.0 %/VAC; IEC/EN/BS EN62368-1 safety approved; %/VAC |
| Safety Standard | Design refer to UL62368-1 |
| Schutzklasse | CLASS Ⅱ |
| MTBF | MIL-HDBK-217F@25°C–300,000 h |
| CE | recommended circuit) (CISPR32/EN55032 CLASS B (See Fig. 2 for) |
| RE | recommended circuit) (CISPR32/EN55032 CLASS B (See Fig. 2 for) |
| ESD | perf. Criteria B (IEC/EN61000-4-2 Contact ±6 KV/Air ±8 KV) |
| EMS RS | perf. Criteria A (IEC/EN61000-4-3 10V/m) |
| EFT | IEC/EN61000-4-4 ± 2KV (See Fig. 1 for typical: application circuit) perf. Criteria B; IEC/EN61000-4-4 ± 4KV (See Fig. 2 for recommended: circuit) perf. Criteria B; IEC/EN61000-4-5 line to line ±1 KV (See Fig. 1: for typical application circuit) perf. Criteria B |
| Surge | IEC/EN61000-4-5 line to line ±2 KV/line to ground: ±4 KV; perf. Criteria B; (See Fig. 2 for recommended: circuit) |
| CS | perf. Criteria A (IEC/EN61000-4-6 10Vr.m.s) |
| and voltage variation | perf. Criteria B (IEC/EN61000-4-11 0%, 70%) |