Industrial automation. Connected to your next project.Guangzhou Hongwei · Est. 2021
changtaowu6@gmail.com ↗13058353823
Home / Products / DELTA / PJT Series
PJT Series

PJT Series

Publish date: 2026-11-15

Product description: The PJT open frame power supply series offers choices of 12 V, 15 V, 18 V and 24 V nominal output voltages. The single output products are designed with small standard industrial footprints at 3” x 5”. The highly efficient convection cooling designs enable optimum thermal management for high power efficiency. The PJT series of products can operate from -10°C to +70°C across the entire input voltage range of 90 to 264 Vac and are certified for safety standard according to IEC/EN/UL 62368-1 and for EMI standard according to EN/BS EN 55032, Class B.

Product highlights: Models in this series: PJT-12V100WBAA / PJT-12V100WBBA / PJT-12V40WBAA / PJT-12V65WBAA / PJT-15V100WBAA / PJT-15V100WBBA / PJT-15V40WBAA / PJT-15V65WBAA / PJT-18V100WBAA / PJT-18V100WBBA / PJT-18V40WBAA / PJT-18V65WBAA / PJT-24V100WBAA / PJT-24V100WBBA / PJT-24V40WBAA / PJT-24V65WBAA / PJT-27V150WBNA

Price: Price on request

Inquire now +

Scroll down for more details

Email: changtaowu6@gmail.com
WhatsApp: +84 346 271 021 · WeChat: 13058353823
Telephone: +86 130 5835 3823

Product Introduction Cooperation Cases More Products
PRODUCT INTRODUCTION

Product Introduction

Product Description

The PJT open frame power supply series offers choices of 12 V, 15 V, 18 V and 24 V nominal output voltages. The single output products are designed with small standard industrial footprints at 3” x 5”. The highly efficient convection cooling designs enable optimum thermal management for high power efficiency. The PJT series of products can operate from -10°C to +70°C across the entire input voltage range of 90 to 264 Vac and are certified for safety standard according to IEC/EN/UL 62368-1 and for EMI standard according to EN/BS EN 55032, Class B.

Highlights

Models in this series: PJT-12V100WBAA / PJT-12V100WBBA / PJT-12V40WBAA / PJT-12V65WBAA / PJT-15V100WBAA / PJT-15V100WBBA / PJT-15V40WBAA / PJT-15V65WBAA / PJT-18V100WBAA / PJT-18V100WBBA / PJT-18V40WBAA / PJT-18V65WBAA / PJT-24V100WBAA / PJT-24V100WBBA / PJT-24V40WBAA / PJT-24V65WBAA / PJT-27V150WBNA

Selection Guide

ModelOutput PowerOutput Voltage / CurrentAdjustable RangeEfficiencyMax Capacitive Load
PJT-12V100WBAA100W12V / 8.33 A
PJT-12V100WBBA100W12V
PJT-12V40WBAA40W12V
PJT-12V65WBAA65W12V
PJT-15V100WBAA100W15V
PJT-15V100WBBA100W15V
PJT-15V40WBAA40W15V
PJT-15V65WBAA65W15V
PJT-18V100WBAA100W18V
PJT-18V100WBBA100W18V
PJT-18V40WBAA40W18V
PJT-18V65WBAA65W18V
PJT-24V100WBAA100W24V
PJT-24V100WBBA100W24V
PJT-24V40WBAA40W24V
PJT-24V65WBAA65W24V
PJT-27V150WBNA150W27V

Manufacturer documentation

Scroll down for more details

PJT Series datasheet page 1 PJT Series datasheet page 2 PJT Series datasheet page 3 PJT Series datasheet page 4 PJT Series datasheet page 5 PJT Series datasheet page 6 PJT Series datasheet page 7 PJT Series datasheet page 8 PJT Series datasheet page 9 PJT Series datasheet page 10

Specifications

SeriesPJT
ModelPJT-12V100WBAA
BrandDELTA
Surrounding Air Temperature (Operating)-10°C to +70°C
Storage-40°C to +85°C
Power De-rating> 50°C de-rate power by 2.5% / °C
Operating Humidity10 to 95% RH (Non-Condensing)
Operating Altitude0 to 5,000 Meters (16,400 ft.)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine Wave: 50 G for a duration of 11 ms, 3 shocks for each 3 directions
Vibration (Operating)IEC 60068-2-6, Sine Wave: 10 Hz to 150 Hz @ 25 m/S² (2.5 G); 10 min per cycle, 90 min per axis for all X, Y, Z direction
Over Voltage CategoryII Protections
Overvoltage (< 18.0 V,)< 22.5 V, < 27.0 V, < 36.0 V,
Latch Mode (Latch Mode)Latch Mode Latch Mode
Overload / Overcurrent< 150% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
Over TemperatureNon-Latching (Auto-Recovery)
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Internal Fuse at L pinT3.15A
Protection Against ShockClass I with PE* connection *PE: Primary Earth Reliability Data
MTBF> 700,000 hrs. as per Telcordia SR-332 Safety Standards / Directives
Electrical Safety (TUV Bauart)EN 60950-1, EN 62368-1
UL/cUL recognizedUL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881)
CB schemeIEC 60950-1, IEC 62368-1
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
UKCAIn conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
Galvanic Isolation (Input to Output)3.0 KVac
Input to Ground1.5 KVac
Output to Ground0.5 KVac PJT Open Frame Power Supply PJT-100WBAA Series / PJT-□□V100WBAA EMC
Emissions (CE & RE)CISPR 32, EN/BS EN 55032, FCC Title 47: Class B
ImmunityEN/BS EN 55024
Electrostatic Discharge (IEC 61000-4-2)Criteria A1) Level 3 Air Discharge: 8 kV Level 3 Contact Discharge: 6 kV
Radiated Field (IEC 61000-4-3)Level 2 Criteria A1) 80 MHz-1 GHz, 3 V/M with 1 kHz tone / 80% modulation
Electrical Fast Transient / Burst (IEC 61000-4-4)Level 3 Criteria A1) 2 kV
Surge (IEC 61000-4-5)Level 3 Criteria A1) Common Mode2): 2 kV Differential Mode3): 1 kV
Conducted (IEC 61000-4-6)Level 2 Criteria A1) 3 V with 80% AM
Power Frequency Magnetic Fields (IEC 61000-4-8)Criteria A1) Magnetic field strength 3 A/Meter
Voltage Dips (IEC 61000-4-11)30% dip; 25 ms Criterion A 60% dip; 100 ms Criterion B 95% dip; 5000 ms Criterion B
Harmonic Current EmissionIEC/EN/BS EN 61000-3-2, Class A
Voltage Fluctuation and FlickerIEC/EN/BS EN 61000-3-3 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) Block Diagram PJT Open Frame Power Supply PJT-100WBAA Series / PJT-□□V100WBAA Dimensions L x W x H: 127 x 76.2 x 31 mm [3” x 5”] Item Device Description Pin 1: Neutral Pin 2: NC Pin 3: Line Pin 1 to 4: V(+) Pin 5 to 8: V(–)
1.Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1.
2.If the output capacity is not reduced when the surrounding air temperature >50°C, the device will run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition.
3.Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot!
4.If the device has to be mounted in any other orientation, please leave a message via the Contact Us form.
Fig. 1De-rating for Horizontal Mounting Orientation > 50°C de-rate power by 2.5% / °C Output Load De-rating VS Input Voltage voltage from 90 Vac to 264 Vac PJT Open Frame Power Supply PJT-100WBAA Series / PJT-□□V100WBAA Assembly & Installation Any excessive twisting or bending may damage the device’s PCB. Please handle the device with care. Base Mounting (Horizontal)
Fig. 2Recommended Mounting Orientation Use cable of AWG No. 22-18. Please refer to Table 1 for the recommended Mating Connector and Terminal.
Table 1 (Input / Output)Power Supply Header Mating Connector Terminal
A – JST connector (Input)B2P3-VH (LF)(SN) VHR-3N SVH-21T-P1.1
Output (B8P-VH (LF)(SN))VHR-8N SVH-21T-P1.1 Safety Instructions secondary side safety distance from other components and equipments. Please insert an insulation sheet between the system and product, if the safety distance is less than 4 mm. In addition, to ensure sufficient convection cooling, always maintain a distance of ≥ 20 mm (0.79 inch) from ventilated surfaces while the device is in operation. device while it is in operation or immediately after power is turned OFF. Risk of burning!
Inrush CurrentDynamic Response Inrush current is the peak, instantaneous, input current measured The power supply output voltage will remain within ±5% of its and, occurs when the input voltage is first applied. For AC input steady state value, when subjected to a dynamic load from 0 to voltages, the maximum peak value of inrush current will occur 50% and 50 to 100% of its rated current. during the first half cycle of the applied AC voltage. This peak value
Overload & Overcurrent Protections (Auto-Recovery)Overvoltage Protection (Latch Mode)
The power supply’s Overload (OLP) and Overcurrent (OCP)The power supply’s overvoltage circuit will be activated when its Protections will be activated when output current exceeds 150% of internal feedback circuit fails. The output voltage shall not exceed IO (Max load). In such occurrence, the VO will start to droop and its specifications defined on Page 3 under “Protections”. Power once the power supply has reached its maximum power limit, the supply will latch off, and require removal/re-application of input AC
Short Circuit Protection (Auto-Recovery)OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output
The power supply’s output OLP/OCP function also providesvoltage will go into bouncing mode until the temperature drops to protection against short circuits. When a short circuit is applied, the its normal operating temperature as recommended in the de-rating output current will operate in “Hiccup mode”, as shown in the graph. illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed.
ThailandTaiwan
Delta Electronics (Thailand) PCL.Delta Electronics, Inc.
909 Pattana 1 Rd., Muang, Samutprakarn, 10280 Thailand3 Tungyuan Road, Chungli Industrial Zone, Taoyuan County 32063, Taiwan Authorized Representatives
The NetherlandsUnited Kingdom
Delta Greentech (Netherlands) B.V.Delta Electronics Europe Limited
Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands1 Redwood Court, Peel Park Campus, East Kilbride, Glasgow, G74 5PF, United Kingdom

Send your full model number, required quantity, input voltage and application details. We will confirm availability and quotation.

Series Comparison

SeriesTypeOutput PowerOutput VoltageModel
PJOpen-Frame Power Supplies——PJ-12V100W
PJBOpen-Frame Power Supplies——PJB-24V100W
PJHOpen-Frame Power Supplies——PJH-24V300WBBA
PJLOpen-Frame Power Supplies——PJL-48V200WBAA
PJTOpen-Frame Power Supplies——PJT-12V100WBAA
PJUOpen-Frame Power Supplies——PJU-13V60WCBA

Why choose us

  • Genuine products

    All products are genuine and come with manufacturer documentation and factory support.

  • Model-direct sourcing

    No guesswork — engineers and buyers communicate by exact model number.

  • Landed-cost quotation

    Quotes include price, stock, compatibility and export shipping — full cost, no surprises.

  • Global export

    Serving overseas engineers, buyers and integrators with multi-country shipping.

  • Multi-channel support

    Email, WhatsApp, phone and WeChat — fast responses.

  • One-stop sourcing

    Power supplies, drives, sensors and low-voltage components in one place.

Cooperation Cases

More cases →

More Products

Browse all products →

YOUR SOURCING REQUEST

Inquiry list

EmailDestination

Email opens your email app. WhatsApp opens a prepared message. Review and send your inquiry there; it is not submitted automatically.

Products
body>