| Series | PJT |
| Model | PJT-12V100WBAA |
| Brand | DELTA |
| Surrounding Air Temperature (Operating) | -10°C to +70°C |
| Storage | -40°C to +85°C |
| Power De-rating | > 50°C de-rate power by 2.5% / °C |
| Operating Humidity | 10 to 95% RH (Non-Condensing) |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft.) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50 G for a duration of 11 ms, 3 shocks for each 3 directions |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 10 Hz to 150 Hz @ 25 m/S² (2.5 G); 10 min per cycle, 90 min per axis for all X, Y, Z direction |
| Over Voltage Category | II Protections |
| Overvoltage (< 18.0 V,) | < 22.5 V, < 27.0 V, < 36.0 V, |
| Latch Mode (Latch Mode) | Latch Mode Latch Mode |
| Overload / Overcurrent | < 150% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Non-Latching (Auto-Recovery) |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Internal Fuse at L pin | T3.15A |
| Protection Against Shock | Class I with PE* connection *PE: Primary Earth Reliability Data |
| MTBF | > 700,000 hrs. as per Telcordia SR-332 Safety Standards / Directives |
| Electrical Safety (TUV Bauart) | EN 60950-1, EN 62368-1 |
| UL/cUL recognized | UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) |
| CB scheme | IEC 60950-1, IEC 62368-1 |
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016 |
| Galvanic Isolation (Input to Output) | 3.0 KVac |
| Input to Ground | 1.5 KVac |
| Output to Ground | 0.5 KVac PJT Open Frame Power Supply PJT-100WBAA Series / PJT-□□V100WBAA EMC |
| Emissions (CE & RE) | CISPR 32, EN/BS EN 55032, FCC Title 47: Class B |
| Immunity | EN/BS EN 55024 |
| Electrostatic Discharge (IEC 61000-4-2) | Criteria A1) Level 3 Air Discharge: 8 kV Level 3 Contact Discharge: 6 kV |
| Radiated Field (IEC 61000-4-3) | Level 2 Criteria A1) 80 MHz-1 GHz, 3 V/M with 1 kHz tone / 80% modulation |
| Electrical Fast Transient / Burst (IEC 61000-4-4) | Level 3 Criteria A1) 2 kV |
| Surge (IEC 61000-4-5) | Level 3 Criteria A1) Common Mode2): 2 kV Differential Mode3): 1 kV |
| Conducted (IEC 61000-4-6) | Level 2 Criteria A1) 3 V with 80% AM |
| Power Frequency Magnetic Fields (IEC 61000-4-8) | Criteria A1) Magnetic field strength 3 A/Meter |
| Voltage Dips (IEC 61000-4-11) | 30% dip; 25 ms Criterion A 60% dip; 100 ms Criterion B 95% dip; 5000 ms Criterion B |
| Harmonic Current Emission | IEC/EN/BS EN 61000-3-2, Class A |
| Voltage Fluctuation and Flicker | IEC/EN/BS EN 61000-3-3 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) Block Diagram PJT Open Frame Power Supply PJT-100WBAA Series / PJT-□□V100WBAA Dimensions L x W x H: 127 x 76.2 x 31 mm [3” x 5”] Item Device Description Pin 1: Neutral Pin 2: NC Pin 3: Line Pin 1 to 4: V(+) Pin 5 to 8: V(–) |
| 1. | Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. |
| 2. | If the output capacity is not reduced when the surrounding air temperature >50°C, the device will run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. |
| 3. | Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! |
| 4. | If the device has to be mounted in any other orientation, please leave a message via the Contact Us form. |
| Fig. 1 | De-rating for Horizontal Mounting Orientation > 50°C de-rate power by 2.5% / °C Output Load De-rating VS Input Voltage voltage from 90 Vac to 264 Vac PJT Open Frame Power Supply PJT-100WBAA Series / PJT-□□V100WBAA Assembly & Installation Any excessive twisting or bending may damage the device’s PCB. Please handle the device with care. Base Mounting (Horizontal) |
| Fig. 2 | Recommended Mounting Orientation Use cable of AWG No. 22-18. Please refer to Table 1 for the recommended Mating Connector and Terminal. |
| Table 1 (Input / Output) | Power Supply Header Mating Connector Terminal |
| A – JST connector (Input) | B2P3-VH (LF)(SN) VHR-3N SVH-21T-P1.1 |
| Output (B8P-VH (LF)(SN)) | VHR-8N SVH-21T-P1.1 Safety Instructions secondary side safety distance from other components and equipments. Please insert an insulation sheet between the system and product, if the safety distance is less than 4 mm. In addition, to ensure sufficient convection cooling, always maintain a distance of ≥ 20 mm (0.79 inch) from ventilated surfaces while the device is in operation. device while it is in operation or immediately after power is turned OFF. Risk of burning! |
| Inrush Current | Dynamic Response Inrush current is the peak, instantaneous, input current measured The power supply output voltage will remain within ±5% of its and, occurs when the input voltage is first applied. For AC input steady state value, when subjected to a dynamic load from 0 to voltages, the maximum peak value of inrush current will occur 50% and 50 to 100% of its rated current. during the first half cycle of the applied AC voltage. This peak value |
| Overload & Overcurrent Protections (Auto-Recovery) | Overvoltage Protection (Latch Mode) |
| The power supply’s Overload (OLP) and Overcurrent (OCP) | The power supply’s overvoltage circuit will be activated when its Protections will be activated when output current exceeds 150% of internal feedback circuit fails. The output voltage shall not exceed IO (Max load). In such occurrence, the VO will start to droop and its specifications defined on Page 3 under “Protections”. Power once the power supply has reached its maximum power limit, the supply will latch off, and require removal/re-application of input AC |
| Short Circuit Protection (Auto-Recovery) | OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output |
| The power supply’s output OLP/OCP function also provides | voltage will go into bouncing mode until the temperature drops to protection against short circuits. When a short circuit is applied, the its normal operating temperature as recommended in the de-rating output current will operate in “Hiccup mode”, as shown in the graph. illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. |
| Thailand | Taiwan |
| Delta Electronics (Thailand) PCL. | Delta Electronics, Inc. |
| 909 Pattana 1 Rd., Muang, Samutprakarn, 10280 Thailand | 3 Tungyuan Road, Chungli Industrial Zone, Taoyuan County 32063, Taiwan Authorized Representatives |
| The Netherlands | United Kingdom |
| Delta Greentech (Netherlands) B.V. | Delta Electronics Europe Limited |
| Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands | 1 Redwood Court, Peel Park Campus, East Kilbride, Glasgow, G74 5PF, United Kingdom |