Industrial automation. Connected to your next project.Guangzhou Hongwei · Est. 2021
changtaowu6@gmail.com ↗13058353823
Home / Products / DELTA / PJL Series
PJL Series

PJL Series

Publish date: 2026-11-15

Product description: The PJL-48V200WBAA comes with a + 48 V nominal main output. The open frame power supply is designed with small standard industrial 3” x 5” footprint for lighting application. The highly efficient fan cool and convection cooled design with optimum thermal management for high power efficiency. The product can operate from -40°C to +70°C across the entire input voltage range of 85 to 305Vac and features low earth leakage current as well as low inrush current. The built-in active PFC product has safety approval for lighting application according to UL 8750, IEC 61347-2-13 and major international safety standard according to IEC 60950-1, IEC 62368-1 and is certified for EMI standards according to EN/BS EN 55032 Class B.

Product highlights: Models in this series: PJL-48V200WBAA / PJL-48V400WBAA

Price: Price on request

Inquire now +

Scroll down for more details

Email: changtaowu6@gmail.com
WhatsApp: +84 346 271 021 · WeChat: 13058353823
Telephone: +86 130 5835 3823

Product Introduction Cooperation Cases More Products
PRODUCT INTRODUCTION

Product Introduction

Product Description

The PJL-48V200WBAA comes with a + 48 V nominal main output. The open frame power supply is designed with small standard industrial 3” x 5” footprint for lighting application. The highly efficient fan cool and convection cooled design with optimum thermal management for high power efficiency. The product can operate from -40°C to +70°C across the entire input voltage range of 85 to 305Vac and features low earth leakage current as well as low inrush current. The built-in active PFC product has safety approval for lighting application according to UL 8750, IEC 61347-2-13 and major international safety standard according to IEC 60950-1, IEC 62368-1 and is certified for EMI standards according to EN/BS EN 55032 Class B.

Highlights

Models in this series: PJL-48V200WBAA / PJL-48V400WBAA

Selection Guide

ModelOutput PowerOutput Voltage / CurrentAdjustable RangeEfficiencyMax Capacitive Load
PJL-48V200WBAA200W48V / 4.17 A
PJL-48V400WBAA400W48V

Manufacturer documentation

Scroll down for more details

PJL Series datasheet page 1 PJL Series datasheet page 2 PJL Series datasheet page 3 PJL Series datasheet page 4 PJL Series datasheet page 5 PJL Series datasheet page 6 PJL Series datasheet page 7 PJL Series datasheet page 8 PJL Series datasheet page 9 PJL Series datasheet page 10 PJL Series datasheet page 11 PJL Series datasheet page 12 PJL Series datasheet page 13 PJL Series datasheet page 14

Specifications

SeriesPJL
ModelPJL-48V200WBAA
BrandDELTA
Cooling System (Convection)0-150 W
Fan Cool151-200 W With 400 LFM fan cool, 15mm distance between PSU and fan
Power Supply Header (Input (CN1))1-1123724-3
Output (CN2)1-1123723-4
Wire (Input (CN1))AWG 18
Noise (1 Meter from power supply)Sound Pressure Level (SPL) < 25 dBA Environment
Surrounding Air Temperature (Operating)-40°C to +70°C
Storage-40°C to +85°C
Power De-rating (Temperature)> 50°C de-rate power by 3.75 W / °C
(Convection)(150 W @ 50°C, 112.5 W @ 60°C, 75 W @ 70° C)
Temperature> 50°C de-rate power by 5 W / °C
Input Voltage< 100 Vac de-rate power by 1.33% / Vac (80% load at 85 Vac)
Cold Temperature< -20°C de-rate power by 2W / °C (80% load at -40°C)
Operating and Storage Humidity5 to 95% RH (Non-Condensing)
Operating Altitude0 to 5,000 Meters (16,400 ft.)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine 50 G for a duration of 11 ms, 3 times per direction, 9 times in total
Vibration (Non-Operating)IEC 60068-2-6, 10 Hz to 150 Hz @ 25 m/S² (2.5 G peak); displacement of 0.35 mm; 90 min per axis for all X, Y, Z direction
Over Voltage CategoryII Protections
Output Overvoltage< 60 V, SELV Output, Latch Mode
Input Under VoltageBrownout & Brownout Recovery protection
Overload / Overcurrent> 105% of rated load current, Hiccup mode, Non-Latching (Auto recovery)
Over TemperatureLatch Mode
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Internal Fuse at L pinT4AH
Protection Against ShockClass I with PE* connection *PE: Primary Earth PJL Open Frame Power Supply 48 V 200 W 1 Phase / PJL-48V200WBAA Reliability Data
MTBF> 500,000 hrs. as per Telcordia SR-332 I/P: 115Vac, O/P: 100% load, Ta: 25°C
Expected Cap Life Time10 years (115 Vac & 230 Vac, 50% load @ 40°C) Safety Standards / Directives
Safety Entry Low VoltageSELV (IEC 60950-1)
Electrical Safety (SIQ Bauart)EN 62368-1
cCSAusCSA C22.2 No. 250.13 and UL 8750 CSA C22.2 No. 60950-1 and UL 60950-1 CSA C22.2 No. 62368-1 and UL 62368-1
CB schemeIEC 60950-1, IEC 62368-1, IEC 61347-1 and IEC 61347-2-13
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
UKCAIn conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
Galvanic Isolation (Input to Output)4 kVac (Reinforced) 3 kVac (Production Test)
Input to Ground1.5 kVac (Basic & Production Test)
Output to Ground1.5 kVac (Basic)
Isolation Resistance (Input to Output)> 100 MOhm
PE Resistance< 0.1 Ohm EMC
Emissions (CE & RE)Generic Standards: CISPR 32, EN/BS EN 55032: Class B
ImmunityGeneric Standards: EN/BS EN 55024, EN/BS EN 55035
Electrostatic Discharge (IEC 61000-4-2)Level 3 Criteria A1) Air Discharge: 8 kV Contact Discharge: 6 kV
Radiated Field (IEC 61000-4-3)Level 3 Criteria A1) 80 MHz-1 GHz, 10 V/M, 80% modulation (1 kHz)
Electrical Fast Transient / Burst (IEC 61000-4-4)Level 3 Criteria A1) 2 kV (Input power ports)
Surge (IEC 61000-4-5)Level 3 Criteria A1) Common Mode3): 2 kV Differential Mode4): 1 kV
Conducted (IEC 61000-4-6)Level 3 Criteria A1) 150 kHz-80 MHz, 10 Vrms
Power Frequency Magnetic Fields (IEC 61000-4-8)Criteria A1) 10 A/Meter
Voltage Dips and Interruptions (IEC 61000-4-11)100% dip; 1 cycle (20 ms); Self Recoverable
Low Energy Pulse Test (IEC 61000-4-12)Level 3 Criteria A1)
(Ring Wave)Common Mode3): 2 kV Differential Mode4): 1 kV
Harmonic Current EmissionIEC/EN/BS EN 61000-3-2, Class C
Voltage Fluctuation and FlickerIEC/EN/BS EN 61000-3-3 at nominal voltages and full 1) Criteria A: Normal performance within the specification limits 3) Asymmetrical: Common mode (Line to earth) 2) Criteria B: Temporary degradation or loss of function which is self-recoverable 4) Symmetrical: Differential mode (Line to line) PJL Open Frame Power Supply 48 V 200 W 1 Phase / PJL-48V200WBAA Block Diagram PJL Open Frame Power Supply
1.Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1.
2.If the output capacity is not reduced when the surrounding air temperature exceeds its specification as defined on Page 3 under “Environment”, the device will run into Over Temperature Protection. When activated, power supply will latch off, until the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition, and require removal/re-application of input AC voltage in
3.In order for the device to function in the manner intended, it is also necessary to keep a safety distance as recommended in the safety instructions while the device is in operation.
4.Depending on the surrounding air temperature
Fig. 1and output load delivered by the power supply, the device can be very hot!
Temperature (Power De-rating)5. If the device has to be mounted in any other
Fan cool (orientation,)please contact > 50°C de-rate power by 5 W / °C info@deltapsu.com for more details. (200 W @ 50°C, 150 W @ 60°C, 100 W @ 70°C) < -20°C de-rate power by 1% / °C (160 W @ -40°C)
Fig. 2Installation of the Device
Fig. 3Assembly Reference

Send your full model number, required quantity, input voltage and application details. We will confirm availability and quotation.

Series Comparison

SeriesTypeOutput PowerOutput VoltageModel
PJOpen-Frame Power Supplies——PJ-12V100W
PJBOpen-Frame Power Supplies——PJB-24V100W
PJHOpen-Frame Power Supplies——PJH-24V300WBBA
PJLOpen-Frame Power Supplies——PJL-48V200WBAA
PJTOpen-Frame Power Supplies——PJT-12V100WBAA
PJUOpen-Frame Power Supplies——PJU-13V60WCBA

Why choose us

  • Genuine products

    All products are genuine and come with manufacturer documentation and factory support.

  • Model-direct sourcing

    No guesswork — engineers and buyers communicate by exact model number.

  • Landed-cost quotation

    Quotes include price, stock, compatibility and export shipping — full cost, no surprises.

  • Global export

    Serving overseas engineers, buyers and integrators with multi-country shipping.

  • Multi-channel support

    Email, WhatsApp, phone and WeChat — fast responses.

  • One-stop sourcing

    Power supplies, drives, sensors and low-voltage components in one place.

Cooperation Cases

More cases →

More Products

Browse all products →

YOUR SOURCING REQUEST

Inquiry list

EmailDestination

Email opens your email app. WhatsApp opens a prepared message. Review and send your inquiry there; it is not submitted automatically.

Products
body>