| Series | PJH |
| Model | PJH-24V300WBBA |
| Brand | DELTA |
| Dimensions (L x W x H) | 127 x 76.2 x 35.8 mm (5.00 x 3.00 x 1.41 inch) |
| Indicator (Green LED) | DC OK |
| Cooling System (Convection) | V1: 0-240 W VSB: 0-3 W |
| Fan Cool (V1: 0-300 W) | VSB: 0-6 W Note: With 10 CFM fan cool, 10 cm distance between PSU and fan |
| Power Supply Header (Input (CN1)) | B2P3-VH(LF)(SN) |
| Output (CN102, 103) | TERMINAL M3 x 0.5 |
| Standby (CN101) | BM10B-SRSS-TB(LF)(SN) |
| Wire (Input (CN1)) | AWG 18 |
| Noise (1 Meter from power supply) | Sound Pressure Level (SPL) < 25 dBA Environment |
| Surrounding Air Temperature (Operating) | -25°C to +70°C (Cold Start -40°C) |
| Storage | -40°C to +85°C |
| Power De-rating (Temperature) | Refer to Output Load De-rating VS Surrounding Air Temperature Fig.1 |
| (Convection) | on Page 9 |
| Temperature | > 50°C de-rate power by 7.5W / °C |
| (Fan Cool) | (300 W @ 50°C, 225 W @ 60°C, 150 W @ 70°C with 10 CFM fan cool) |
| Operating and Storage Humidity | 5 to 95% RH (Non-Condensing) |
| Operating Altitude (PD3) | 0 to 5,000 Meters (16,400 ft.), Class I |
| PD2 | 0 to 3,000 Meters (9,840 ft.), Class II |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine 30G for a duration of 18 ms, 3 times per direction, 9 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, 10 Hz to 500 Hz @ 30 m/S² (3G peak); displacement of 0.35 mm; 60 min per axis for all X, Y, Z direction |
| Bump Test (Operating) | IEC 60068-2-29, Half Sine 10 G (100 m/S²) for a duration of 11 ms, 1,000 times per direction, 6,000 times in total |
| Over Voltage Category | Design to OVC III according to IEC/EN 61558 |
| Pollution Degree (Class I) | PD3 (with PE* connection) |
| Class II | PD2 *PE: Primary Earth PJH Open Frame Power Supply PJH-300W series / PJH-□V300WB□A Protections |
| Output Overvoltage (V1 and VSB) | SELV Output, Latch Mode |
| V1 (26 ~ 33 V, SELV Output,) | 39 ~ 46.8 V, SELV Output, |
| Latch Mode | Latch Mode |
| 5 VSB | 6.3 V - 7.7 V, SELV Output, Latch Mode |
| 12 VSB | 13 V – 15 V, SELV Output, Latch Mode |
| Overload / Overcurrent | 130 ~ 180% of rated load current, Hiccup mode, Non-Latching (Auto recovery) |
| Over Temperature | Latch Mode |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Transient Surge Voltage Protection | MOV (Metal Oxide Varistor) |
| Internal Fuse at L pin | T 5AL |
| Protection Against Shock | Class I with PE* connection, Class II without PE* connection Note: Refer to the details in the Pollution Degree and EMC section *PE: Primary Earth Reliability Data |
| MTBF | > 700,000 hrs. as per Telcordia SR-332 I/P: 115 Vac, O/P: 80% load or 240 W, Ta: 25°C |
| Expected Cap Life Time | 10 years (115 Vac, 40% load or 120 W @ 40°C) Safety Standards / Directives |
| Safety Entry Low Voltage | SELV (IEC 60950-1) |
| Electrical Safety (SIQ Bauart) | EN 62368-1, EN 60335-1, EN 61558-1, EN 61558-2-16 |
| UL/cUL recognized | UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) |
| CB scheme | IEC 60950-1, IEC 62368-1, IEC 60335-1, IEC 61558-1, IEC 61558-2-16 |
| UKCA | BS EN 62368-1 |
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation (PD3, Class I) | Input to Output 4.0 kVac |
| Input to Ground | 2.0 kVac (PD3, Class I) 4.0 kVac (PD2, Class II with Functional Ground) |
| Output to Ground | 1.5 kVac |
| Isolation Resistance (Input to Output) | > 5 MOhm PJH Open Frame Power Supply PJH-300W series / PJH-□V300WB□A EMC |
| Conducted Emissions (Input Line) | Generic Standards: CISPR 11, CISPR 32, EN/BS EN 55011, EN/BS EN 55032, FCC Title 47, EN 55014-1 Class B: • For protection Class I, with PE* connection • For protection Class II, with FG** connection Class A: • For protection Class II, without FG connection *PE: Primary Earth, **FG: Functional Ground |
| Output Line | EN55014-1 Class A |
| Radiated Emission | Generic Standards: CISPR 11, CISPR 32, EN/BS EN 55011, EN/BS EN 55032, FCC Title 47, EN 55014-1: Class B |
| Immunity | Generic Standards: EN 55024, EN 55035, EN 55014-2, EN 61204-3 |
| Electrostatic Discharge (IEC 61000-4-2) | Level 4 Criteria A1) Air Discharge: 8 kV Contact Discharge: 15 kV |
| Radiated Field (IEC 61000-4-3) | Level 3 Criteria A1) 80 MHz - 1 GHz, 10 V/M, 80% modulation (1 kHz) 1.4 GHz - 2 GHz, 10 V/M, 80% modulation (1 KHz) 2 GHz - 2.7 GHz, 10 V/M, 80% modulation (1 KHz) |
| Electrical Fast Transient / (IEC 61000-4-4) | Level 3 Criteria A1) |
| Burst | 2 kV (Input power ports) |
| Surge (IEC 61000-4-5) | Level 3 Criteria A1) Common Mode3): 2 kV Differential Mode4): 1 kV |
| Conducted (IEC 61000-4-6) | Level 3 Criteria A1) 150 kHz-80 MHz, 10 Vrms |
| Power Frequency Magnetic (IEC 61000-4-8) | Criteria A1) |
| Fields | 30 A/Meter |
| Voltage Dips and Interruptions (IEC 61000-4-11) | 100% dip; 1 cycle (20 ms); Self Recoverable |