Industrial automation. Connected to your next project.Guangzhou Hongwei · Est. 2021
changtaowu6@gmail.com ↗13058353823
Home / Products / MORNSUN / LOF400-20BxxR2 Series
LOF400-20BxxR2 Series

LOF400-20BxxR2 Series

Publish date: 2026-11-15

Product description: LOF400-20BxxR2 series is one of Mornsun’s AC-DC miniaturize open frame power supply and suitable for all kinds of BF type (be accessible to patients) medical system equipment. It features universal AC input and at the same time accepts DC input voltage, cost-effective, high efficiency, high reliability and double or reinforced insulation. These converters offer excellent EMC and safety performance, which meet IEC/EN/UL/BS EN62368、GB4943、IEC/EN60335、IEC/EN61558、IEC/EN/ES60601、IEC60950 standards and they are widely used in areas of industrial, LED, street light control, security, telecommunications, smart home, medical, etc.

Product highlights: Models in this series: LOF400-20B12R2 / LOF400-20B24R2 / LOF400-20B48R2

Price: Price on request

Inquire now +

Scroll down for more details

Email: changtaowu6@gmail.com
WhatsApp: +84 346 271 021 · WeChat: 13058353823
Telephone: +86 130 5835 3823

Product Introduction Cooperation Cases More Products
PRODUCT INTRODUCTION

Product Introduction

Product Description

LOF400-20BxxR2 series is one of Mornsun’s AC-DC miniaturize open frame power supply and suitable for all kinds of BF type (be accessible to patients) medical system equipment. It features universal AC input and at the same time accepts DC input voltage, cost-effective, high efficiency, high reliability and double or reinforced insulation. These converters offer excellent EMC and safety performance, which meet IEC/EN/UL/BS EN62368、GB4943、IEC/EN60335、IEC/EN61558、IEC/EN/ES60601、IEC60950 standards and they are widely used in areas of industrial, LED, street light control, security, telecommunications, smart home, medical, etc.

Highlights

Models in this series: LOF400-20B12R2 / LOF400-20B24R2 / LOF400-20B48R2

Selection Guide

ModelOutput PowerOutput Voltage / CurrentAdjustable RangeEfficiencyMax Capacitive Load
LOF400-20B12R223CFM 399.6 Air cooling 252.011.4-12.6 / 12V/33.3A 24V/10.5A50 94.03000
LOF400-20B24R223CFM 400.8 Air cooling 254.422.8-25.2 / 24V/16.7A 48V/5.3A600/3 25 94.51600
LOF400-20B48R223CFM 403.245.6-50.4 / 48V/8.4A12.5 95.01200

Manufacturer documentation

Scroll down for more details

LOF400-20BxxR2 Series datasheet page 1 LOF400-20BxxR2 Series datasheet page 2 LOF400-20BxxR2 Series datasheet page 3 LOF400-20BxxR2 Series datasheet page 4 LOF400-20BxxR2 Series datasheet page 5 LOF400-20BxxR2 Series datasheet page 6

Specifications

SeriesLOF400-20BxxR2
ModelLOF400-20B24R2
TypeMedical Power Supplies
BrandMORNSUN
Input Voltage Range (Rated)100–240 VAC
Input Voltage Range (AC)80–264
Input Voltage Range (DC)110–370 VDC
Input Voltage FrequencyHz; AC input: 47–63 Hz; Rated input (Certified voltage): 5.0 Hz
Input Current115VAC: 5.0A max; 230VAC: 2.5A max; 115VAC: 40A
Inrush Current230VAC: 80A; 115VAC: 0.98A (Cold start)
Power Factor0.95 @230VAC
Input Fuse8A (Built-in fuse)
Hot PlugUnavailable
Output Voltage Accuracy±3.0% (Full load range)
Line Regulation±0.5% (Rated load)
Load Regulation±1.0% (0% - 100% load)
Minimum Load0 (At room temperature, 230VAC input (when PS_ON is at; high potential))
Stand-by Power ConsumptionVdd voltage: 3.3-15V, Vdd supply current requirement:: 0.5W; 5mA.When PS_ON is at a high level to SGND, the power: W; output is turned off: W; 12V: 120W; W (20MHz bandwidth)
Ripple & Noise24V: 200mV max; (peak-peak value): mV; 48V: 250mV max
Temperature Coefficient±0.03%/℃; Air cooling (250W Load): 30%/℃
Hold-up Time230VAC, rated load, 25℃: ms; 23CFM (400W Load): 16 ms
Short Circuit ProtectionRecovery time <3s after the short circuit disappear.: Hiccup, continuous, self-recover; ≥105% Io, hiccup, self-recover (Normal temperature,; high temperature)
Over-current Protection100-240VAC, rated load: hiccup,; ≥105% full load after derating, hiccup,; Low temperature: hiccup,; self-recover hiccup,; 12V: ≤16.0VDC (Hiccup, self-recover) hiccup,
Over-voltage Protection24V: ≤33VDC (Hiccup, self-recover); 48V: ≤60VDC (Hiccup, self-recover); 115VAC, 100% load: 65–90 %Vo (Over-temperature; protection start)
Over-temperature ProtectionRecommended external: ℃; Over-temperature: ℃; wind environment: 23CFM: 50 to 75℃; protection release: ℃; Provide 12V/0.5A output for the fan, with; voltage accuracy of-15% to +15% under t
Fan powerhe premise that the main output is greate; r than 20% of the rated load (12V)
2. *The “Tip and barrel method” isand 0.1uF ceramic capacitor, please refer to AC-DC (used for ripple and noise test, output parallel 10uF electrolytic capacitor)
Isolation (Input–Output)4000 VAC
Isolation2000 VAC (Electric strength test for 1min., leakage current <5mA)
Isolation (Output–⏚)1500 VAC
Isolation (Input–⏚)100 VAC
Insulation ResistanceInput - output Relative humidity: < 95%RH, no condensation: 100 MΩ; Test voltage: 500VDC: MΩ; Output -: 100 MΩ
Operating Temperature-40 to 85℃
Storage Temperature-40–85℃
Storage Humidity10–95 %RH; No condensation: %RH
Operating Humidity20–90%/℃; 23CFM -40℃ to +50℃: 0 %/℃; rated power 400W +50℃ to +70℃: 1.87 %/℃; +70℃ to +85℃: 3.0 %/℃; Operating 230VAC: %/℃; -40℃ to +45℃: 0 %/℃; temperatu: %/℃; Air cooling: %/℃; re derating +45℃ to +60℃: 1.5 %/℃
Power Deratingrated power: %/VAC; 250W +60℃ to +70℃: 1.0 %/VAC; 115VAC -40℃ to +40℃: 0 %/VAC; +40℃ to +70℃: 1.42 %/VAC; Input voltage 80VAC-115VAC: 1.142 %/VAC; derating 115VAC-264VAC: 0 %/VAC; Touch current: <0.1mA %/VAC
Leakage CurrentEarth leakage current: <0.5mA max; BS EN62368-1, EN62368-1(Report); Design refer to IEC/UL62368-1, (240VAC, 60Hz)
Safety StandardGB4943.1; –IEC/EN60335-1; IEC/EN61558-1; –IEC/EN/ES60601-1; CLASS I (with PE and must be
Safety Classconnected)/; CLASS II (without PE)
MTBF≥200,000 h (MIL-HDBK-217F@25℃)
Warranty3 years (Ambient temperature: <25℃)
ItemOperating Conditions Min.: Typ. typ, Max. max Unit; External power: Unit; Vdd voltage 3.3: 15 Unit; supply: Unit
PS_ON Input SignalPower on PS_ON low 0: 0.6V; Power off PS_ON high 3.3: 24V; High level High 2: 5V; Low level Low 0: 1V; The PG signal goes high: V
PG SignalPower on with 10ms to 500ms delay 10: 500 ms; after power set up: ms; The TTL signal goes low at: ms; Power: ms; least 1ms before output 1: ms; off/Power fail: ms; below 90% of rated value: ms; The total compensation voltage value when Vs+ and Vs-: ms; (pins S1 and S2 of CN2) are respectively short-circuited: ms
Remote compensation--: 0.5V; to the output load terminals (RS+ short-circuited to +Vo,: V; RS- short-circuited to -VO): V; Main output Normal output: Green on V
LED SignalPower off (AC without Input): Light off; When: RS+ and RS- are connected to the system, (status; indication)
Remote Sensewith: function of remote voltage compensation,; if not needed, left RS+ and RS- open
High and Low TemperatureGB2423.1, typ, IEC60068-2-1 max (Working +85℃, -40℃)
Sinusoidal VibrationGB2423.10, typ, IEC60068-2-6 max (10 - 500Hz, 2g, three directions of X, Y, Z axis)
Alternating Hot and HumidGB2423.4, typ, IEC60068-2-30 max (+25℃, 95%RH - +60℃, 95%RH)
Low Temperature StorageGB2423.1, typ, IEC60068-2-1 max (-40℃)
High Temperature StorageGB2423.2, typ, IEC60068-2-2 max (+85℃)
High Temperature AgingGB2423.2, typ, IEC60068-2-2 max (+50℃ (23CFM, Full load))
Normal Temperature AgingGB2423.1, typ, IEC60068-2-1 max (+25℃ (23CFM, Full load))
Temperature ShockGB2423.22, typ, IEC60068-2-14 max (-40℃ to +85℃)
Temperature CycleGB2423.22, typ, IEC60068-2-14 max (-25℃ to +50℃)
Hot and HumidGB2423.50, typ, IEC60068-2-67 max (+85℃, 85%RH)
High Temperature ElevationGB2423.26, typ, IEC60068-2-41 max (+60℃, 54KPa)
Low Temperature ElevationGB2423.25, typ, IEC60068-2-40 max (-25℃, 54KPa)
Constant Humid and HotGB2423.3, typ, IEC60068-2-78 max (+40℃, 95%RH)
Sinusoidal Vibration ResponseGB/T typ, 11287-2000, max IEC60255-21-1 (10 - 150Hz, 1g, three directions of X, Y, Z axis)
Sinusoidal Impulse Response15g, pulse duration 11ms, three times in each direction: of X, IEC60255-21-2; GB/T typ, 114537-1993, max IEC60255-21-2
Packaging DropGB2423.8, typ, IEC68-2-32 max (1m, one corner, three edges and six sides)
Case MaterialOpen frame
Dimension127.00mm × 76.20mm × 27.50mm
Weight410g (Typ.)
Cooling Method *Air cooling (250W) / 23CFM (400W)
EMC EmissionsCE: CISPR32/EN55032 (CLASS I equipment, CLASS B; CLASS II (equipment, CLASS A))
EMC ImmunityHarmonic current: IEC/EN61000-3-2 CLASS A and CLASS D; ESD: IEC/EN 61000-4-2 Contact ±8KV/Air ±15KV (perf. Criteria A); RS: IEC/EN 61000-4-3 10V/m (perf. Criteria A); EFT: IEC/EN 61000-4-4 ±2KV (perf. Criteria A); Surge: IEC/EN 61000-4-5 ±2KV/±4KV (perf. Criteria A); CS: IEC/EN61000-4-6 10 Vr.m.s (perf. Criteria A); Voltage drop: 40% 240 ,10/12 Period(50/60Hz) (perf. Criteria B); Voltage interruption: 0% 240 ,250/300 periods (50/60Hz) (perf. Criteria C)

Send your full model number, required quantity, input voltage and application details. We will confirm availability and quotation.

Series Comparison

SeriesTypeOutput PowerOutput VoltageModel
lh15-20bxxmuMedical Power Supplies——LH15-20B24MU
LO120-20BxxMUMedical Power Supplies——LO120-20B27MU
LO30-20BxxMUMedical Power Supplies——LO30-20B19MU
LO45-20BxxMU(-C)Medical Power Supplies——LO45-20B24MU(-C)
LO45-20BxxSMU(-C)Medical Power Supplies——LO45-20B15SMU(-C)
LO65-20BxxMU(-C)Medical Power Supplies——LO65-20B24MU(-C)
LO65-20BxxSMU(-C)Medical Power Supplies——LO65-20B24SMU(-C)
LO75-20BxxMUMedical Power Supplies——LO75-20B19MU
LOF120-20BxxMedical Power Supplies——LOF120-20B27
LOF120-20Bxx-CSingle Output——LOF120-20B27-C
LOF200-20BxxR2Medical Power Supplies——LOF200-20B27R2
LOF225-20BxxMedical Power Supplies——LOF225-20B24
LOF225-20Bxx-CSingle Output——LOF225-20B24-C
LOF300-20BxxR2Medical Power Supplies——LOF300-20B Air cooling
LOF350-20BxxMedical Power Supplies——LOF350-20B24
LOF350-20Bxx-CMedical Power Supplies——LOF350-20B24-C
LOF400-20BxxR2Medical Power Supplies——LOF400-20B24R2
LOF450-20BxxMedical Power Supplies——LOF450-20B24
LOF450-20Bxx-CSingle Output——LOF450-20B12-CF
LOF450-20Bxx-CFSingle Output——LOF450-20B54-C
LOF500-20BxxR2Medical Power Supplies——LOF500-20B24R2
LOF550-20BxxMedical Power Supplies——LOF550-20B24
lof550-20bxx-cSingle Output——LOF550-20B54-C
LOF550-20Bxx-CFSingle Output——LOF550-20B54-C
LOF600-20BxxR2Medical Power Supplies——LOF600-20B48R2

Why choose us

  • Genuine products

    All products are genuine and come with manufacturer documentation and factory support.

  • Model-direct sourcing

    No guesswork — engineers and buyers communicate by exact model number.

  • Landed-cost quotation

    Quotes include price, stock, compatibility and export shipping — full cost, no surprises.

  • Global export

    Serving overseas engineers, buyers and integrators with multi-country shipping.

  • Multi-channel support

    Email, WhatsApp, phone and WeChat — fast responses.

  • One-stop sourcing

    Power supplies, drives, sensors and low-voltage components in one place.

Cooperation Cases

More cases →

More Products

Browse all products →

YOUR SOURCING REQUEST

Inquiry list

EmailDestination

Email opens your email app. WhatsApp opens a prepared message. Review and send your inquiry there; it is not submitted automatically.

Products
body>