| Series | LOF200-20BxxR2 |
| Model | LOF200-20B27R2 |
| Type | Medical Power Supplies |
| Brand | MORNSUN |
| Input Voltage Range (Rated) | 100–240 VAC |
| Input Voltage Range (AC) | 80–264 |
| Input Voltage Range (DC) | 110–370 VDC |
| Input Voltage Frequency | Hz; AC input: 47–63 Hz; Rated input (Certified voltage): 2.5 Hz |
| Input Current | 115VAC: 2.5A max; 230VAC: 1A max; 115VAC: 40A |
| Inrush Current | 230VAC: 80A; 115VAC: 0.98A (Cold start) |
| Power Factor | 0.95 @230VAC |
| Start-up Delay Time | 1000 ms @115VAC/230VAC, rated load |
| Input Fuse | 6.3A (Built-in fuse) |
| Hot Plug | Unavailable |
| Output Voltage Accuracy | ±3% (Full load range) |
| Line Regulation | ±0.5% (Rated load) |
| Load Regulation | ±1% (0% - 100% load) |
| Minimum Load | 0 |
| Stand-by Power Consumption | 0.5W; 12V: 120W; 15V: 150W; W (20MHz bandwidth) |
| Ripple & Noise | 19V: 190mV max; (peak-peak value): mV; 24/27V: 200mV max; 36/48/54V: 250mV max |
| Temperature Coefficient | ±0.03%/℃; Air cooling: 16%/℃ |
| Hold-up Time | 230VAC, rated load, 25℃: ms; 10.98CFM: 8 ms |
| Short Circuit Protection | Recovery time <30s after the short circuit disappear.: Hiccup, continuous, self-recover; ≥105% Io, hiccup, self-recover (Normal temperature,; high temperature) |
| Over-current Protection | 230VAC, rated load: hiccup,; ≥105% full load after derating, hiccup,; Low temperature: hiccup,; self-recover hiccup,; 12V: ≤16VDC (Hiccup, self-recover) hiccup,; 15V: ≤20VDC (Hiccup, self-recover) hiccup,; 19V: ≤25VDC (Hiccup, self-recover) hiccup,; 24V: ≤32VDC (Hiccup, self-recover) hiccup, |
| Over-voltage Protection | 27V: ≤35VDC (Hiccup, self-recover); 36V: ≤47VDC (Hiccup, self-recover); 48V: ≤60VDC (Hiccup, self-recover); 54V: ≤63VDC (Hiccup, self-recover); 230VAC, Over-temperature protection start: 80 %Vo |
| Over-temperature Protection | ℃; 100% load Over-temperature protection release: 65℃ |
| Fan power | 12/15/19/24/27/36/48/54V: Provide 12V/0.5A output for the fan, with; voltage accuracy of; ±15% under the premise that the main; output is greater than 20% of the rated load |
| 2. *The “Tip and barrel method” is | and 0.1uF ceramic capacitor, please refer to AC-DC (used for ripple and noise test, output parallel 47uF electrolytic capacitor) |
| Isolation (Input–Output) | 4000 VAC |
| Isolation | 2000 VAC (Electric strength test for 1min., leakage current <5mA) |
| Isolation (Output–⏚) | 1500 VAC |
| Isolation (Input–⏚) | 100 VAC |
| Insulation Resistance | Input - output Relative humidity: < 95%RH, no condensation: 100 MΩ; Test voltage: 500VDC: MΩ; Output -: 100 MΩ |
| Operating Temperature | -40 to +85℃ |
| Storage Temperature | -40–+85℃ |
| Storage Humidity | 10–95 %RH; No condensation: %RH |
| Operating Humidity | 20–90 %RH; PFC: 65 %RH |
| Switching Frequency | KHz; DC-DC: 85; -40℃ to -36℃: 10; -36℃ to +45℃: 0; Air +45℃ to +70℃: 1.2; (140W) -36℃ to +50℃: 0; Operating 230VAC +50℃ to +60℃: 2.5; temperature: %/℃; derating +60℃ to +70℃: 0.5; -40℃ to -35℃: 10 (115VAC; cooling) |
| Power Derating | -35℃ to -30℃: 4; -30℃ to +50℃: 0; +50℃ to +85℃: 1.83; 80VAC-115VAC: 0.86; Input voltage: %/VAC; 115VAC-264VAC: 0; 110VDC-160VDC: 0.6 %/VDC; Altitude derating 2000 - 5000m: 5 %/Km (10.98CFM (200W); derating) |
| Leakage Current | 240VAC, 60Hz Touch current: <0.1mA max EN62368-1,; Design refer to IEC/EN/UL/BS EN62368-1, |
| Safety Standard | IEC/EN60335-1; typ; GB4943.1; min IEC/EN61558-1; IEC/EN/ES60601-1 IEC/EN61558-1; CLASS I (with PE and must be IEC/EN61558-1 |
| Safety Class | connected)/CLASS II (without PE) |
| MTBF | ≥300,000 h (MIL-HDBK-217F@25℃) |
| Warranty | 3 years (Ambient temperature: <50℃) |
| Item | Standard (Operating Conditions) |
| High and Low Temperature | GB2423.1, typ, IEC60068-2-1 max (Working +85℃, -40℃) |
| Sinusoidal Vibration | GB2423.10, typ, IEC60068-2-6 max (10 - 500Hz, 2g, three directions of X, Y, Z axis) |
| Low Temperature Storage | GB2423.1, typ, IEC60068-2-1 max (-40℃) |
| High Temperature Storage | GB2423.2, typ, IEC60068-2-2 max (+85℃) |
| High Temperature Aging | GB2423.2, typ, IEC60068-2-2 max (+50℃) |
| Normal Temperature Aging | GB2423.1, typ, IEC60068-2-1 max (+25℃) |
| Temperature Shock | GB2423.22, typ, IEC60068-2-14 max (-40℃ to +85℃) |
| Temperature Cycle | GB2423.22, typ, IEC60068-2-14 max (-25℃ to +60℃) |
| Hot and Humid | GB2423.50, typ, IEC60068-2-67 max (+85℃, 85%RH) |
| High Temperature Elevation | GB2423.26, typ, IEC60068-2-41 max (+50℃, 54KPa) |
| Low Temperature Elevation | GB2423.25, typ, IEC60068-2-40 max (-25℃, 54KPa) |
| Sinusoidal Vibration Response | GB/T–IEC60255-21-1 (10 - 150Hz, 1g, three directions of X, Y, Z axis) |
| Sinusoidal Impulse Response | 15g, pulse duration 11ms, three times in each direction: of X, IEC60255-21-2; 114537-1993, typ, GB/T min IEC60255-21-2 |
| Packaging Drop | GB2423.8, typ, IEC68-2-32 max (1m, one corner, three edges and six sides) |
| Case Material | Open frame |
| Dimension | 101.60mm × 50.80mm × 25.40mm |
| Weight | 190g (Typ.) |
| Cooling Method | Air cooling (140W) /10.98CFM (200W) |
| EMC Emissions | CE: CISPR32/EN55032 (CLASS I equipment, CLASS B; CLASS II (equipment, CLASS A)) |
| EMC Immunity | Harmonic current: IEC/EN61000-3-2 CLASS A and CLASS D; ESD: IEC/EN 61000-4-2 Contact ±8KV/Air ±15KV (perf. Criteria A); RS: IEC/EN 61000-4-3 10V/m (perf. Criteria A); EFT: IEC/EN 61000-4-4 ±4KV (perf. Criteria A); Surge: IEC/EN 61000-4-5 ±2KV/±4KV (perf. Criteria A); CS: IEC/EN61000-4-6 10 Vr.m.s (perf. Criteria A); PFMF: IEC/EN61000-4-8 30A/m (perf. Criteria A); Voltage short: interruptions IEC/EN61000-4-11 40% of 230Vac, 92Vac, 10/12 cycle (perf. Criteria B); Voltage variations: IEC/EN61000-4-11 0% of 230Vac, 0Vac, 250/300 cycle (perf. Criteria C) |