| Series | LOF120-20Bxx |
| Model | LOF120-20B27 |
| Brand | MORNSUN |
| Input Voltage Range (AC) | 85–264 VAC |
| Input Voltage Range (DC) | 120–370 VDC |
| Input Voltage Frequency | 47–63 Hz; 115VAC: 2 Hz |
| Input Current | 230VAC: 1A max; 115VAC: 40A |
| Inrush Current | 230VAC: 75A; 115VAC: 0.98A (Cold start) |
| Power Factor | 0.94 @230VAC (Full load) |
| Leakage Current | <0.1mA; Single typ, fault<0.5mA max @240VAC |
| Hot Plug | Unavailable |
| Output Voltage Accuracy | 12V/15V: ±2.0%; %; 19V/24V/27V/36V/48V/54V: ±1.0% (Full load range) |
| Line Regulation | ±0.5% (Rated load) |
| Load Regulation | ±1.0%; 12V/15V: 120% (0% - 100% load; 20MHz bandwidth) |
| Ripple & Noise | 19V/24V/27V: 150mV max; mV; 36V/48V/54V: 200mV max ((peak-to-peak value)) |
| Temperature Coefficient | ±0.03%/℃ |
| Minimum Load | 0% |
| Hold-up Time | 15 ms @230VAC, 25℃ |
| Stand-by Power Consumption | 0.5W |
| Short Circuit Protection | Hiccup, continuous, self-recover (Recovery time < 3s after the short circuit disappear) |
| Over-current Protection | ≥130% Io, hiccup, self-recover; ≤16V (Output voltage turn off, re-power on for; recover); ≤25V (Output voltage turn off, re-power on for; recover); ≤25V (Output voltage turn off, re-power on for; recover); ≤32V (Output voltage turn off, re-power on for; recover) (12V; 15V; 19V; 24V) |
| Over-voltage Protection | ≤35V (Output voltage turn off, re-power on for; recover); ≤50V (Output voltage turn off, re-power on for; recover); ≤60V (Output voltage turn off, re-power on for; recover); ≤60V (Output voltage turn off, re-power on for; recover); Output voltage turn off, re-power on to recover (27V; 36V; 48V; 54V) |
| Over-temperature Protection | after abnormal removed |
| Isolation (Input–⏚) | 1500 VAC |
| Isolation (Input–Output) | 4000 VAC (Electric strength test for 1min., leakage current <10mA) |
| Isolation (Output–⏚) | 1500 VAC |
| Insulation Resistance Isolation | Input - output Relative humidity: < 70%RH, no condensation: 100 MΩ; Output - Test voltage: 500VDC: 100 MΩ; Input - output: 2 × MOPP MΩ; Input -: 1 × MOPP MΩ |
| level | 1 × MOPP (Output -) |
| Operating Temperature | -40 to +85℃ |
| Storage Temperature | -40–+85℃ |
| Storage Humidity | 10–95 %RH; Non-condensing: %RH |
| Operating Humidity | 20–90%/℃; +50℃ to +85℃ Air cooling: %/℃; Operating: 2.0 %/℃; temperature +55℃ to +85℃ 10CFM: %/℃; derating: %/℃; -40℃ to -30℃: 2.0 %/℃ |
| Power Derating | Input voltage 85VAC-115VAC Air cooling: 1.0 %/VAC; derating 85VAC-100VAC 10CFM: 2.0; Altitude derating 2000 - 5000m: 5 %/Km; Design refer to IS13252 (Part1), ES60601-1 &; IEC/EN/UL62368-1, typ, BS EN62368-1, min EN60335-1, |
| Safety Standard | IEC/EN61558-1; –IEC/EN60601-1; ES60601-1(3.1version); –CAN/CSA-C22.2; No.60601-1:14-Edition–EN60601-1-2 Edition 4; CLASS I (with PE and must be connected)/ |
| Safety Class | CLASS II (without PE) |
| MTBF | >300,000 h (MIL-HDBK-217F@25℃) |
| Warranty | 5 years (Ambient temperature: <50℃) |
| Case Material | Open frame |
| Dimensions | 76.20mm x 50.80mm x 31.00mm |
| Weight | 125g (Typ.) |
| Cooling Method * | Air cooling / 10CFM |
| EMC Emissions | CE: CISPR32/EN55032 CLASS B; RE: CISPR32/EN55032 (Category I, CLASS B, category (II, CLASS A)) |
| EMC Immunity | Voltage: flicker IEC/EN61000-3-3; ESD: IEC/EN 61000-4-2 Contact ±8KV/Air ±15KV (perf. Criteria A); RS: IEC/EN 61000-4-3 10V/m (perf. Criteria A); EFT: IEC/EN 61000-4-4 ±2KV (perf. Criteria A); Surge: IEC/EN 61000-4-5 line to line ±2KV/line to ground (±4KV perf. Criteria A); CS: IEC/EN61000-4-6 10 Vr.m.s (perf. Criteria A); Voltage: dips, short interruptions |