| Series | PJ |
| Model | PJ-12V100W |
| Brand | DELTA |
| Surrounding Air Temperature (Operating) | -10°C to +70°C |
| Storage | -25°C to +75°C |
| Power De-rating | Refer to Engineering Data Fig.1.1~Fig.1.5 on Page 8~10 |
| Operating Humidity | 5 to 90% RH (Non-Condensing) |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft) |
| Shock Test (Non-Operating) | IEC 60068-2-27, 196.1 m/S² (20 G),11 ms, once along X, Y, and Z axis |
| Vibration (Operating) | IEC 60068-2-6, 10 Hz to 55 Hz @ 19.6 m/S² (2G); 3 min period, 60 min per axis for all X, Y, Z direction |
| Over Voltage Category | II Protections |
| Overvoltage | 13.8-16.8 V, Latch Mode |
| Overload / Overcurrent | > 105% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Internal Fuse at L pin | T3.15AH |
| Protection Against Shock | Class I with PE* connection *PE: Primary Earth Reliability Data |
| MTBF | > 200,000 hrs. as per JEITA RCR-9102B |
| Expected Cap Life Time | 10 years (115 Vac, 50% load @ 40°C) Safety Standards / Directives |
| Safety Entry Low Voltage | SELV |
| Electrical Safety (TUV Bauart) | EN 60950-1, EN 62368-1 |
| UL/cUL recognized | UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) |
| CB scheme | IEC 60950-1, IEC 62368-1 |
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016 |
| Galvanic Isolation (Input to Output) | 3.0 KVac |
| Input to Ground | 2.0 KVac |
| Output to Ground | 0.5 KVac PJ Open Frame Power Supply 12 V 100 W 1 Phase / PJ-12V100W□□A EMC |
| Emissions (CE & RE) | CISPR 32, EN/BS EN 55032, Comply with FCC Title 47: Class B |
| Immunity | EN/BS EN 55024 |
| Electrostatic Discharge (IEC 61000-4-2) | Level 4 Criteria A1) Air Discharge: 15 kV Contact Discharge: 8 kV |
| Radiated Field (IEC 61000-4-3) | Level 3 Criteria A1) 80 MHz - 1 GHz, 10 V/M with 1 kHz tone / 80% modulation |
| Electrical Fast Transient / Burst (IEC 61000-4-4) | Level 3 Criteria A1) 2 kV |
| Surge (IEC 61000-4-5) | Level 3 Criteria A1) Common Mode2): 2 kV Differential Mode3): 1 kV |
| Conducted (IEC 61000-4-6) | Level 3 Criteria A1) 150 kHz - 80 MHz, 10 Vrms |
| Power Frequency Magnetic Fields (IEC 61000-4-8) | Criteria A1) Magnetic field strength 30A/Meter |
| Voltage Dips and Interruptions (IEC 61000-4-11) | 100% dip; 1 cycle (20ms); Self Recoverable |
| Low Energy Pulse Test (Ring Wave) (IEC 61000-4-12) | Level 3 Criteria A1) Common Mode2): 2 kV Differential Mode3): 1 kV |
| Harmonic Current Emission | IEC/EN/BS EN 61000-3-2, Class A |
| Voltage Fluctuation and Flicker | IEC/EN/BS EN 61000-3-3 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) Block Diagram PJ Open Frame Power Supply 12 V 100 W 1 Phase / PJ-12V100W□□A Dimensions Open Frame L x W x H: 155 x 62 x 33 mm (6.10 x 2.44 x 1.32 inch) L Frame L x W x H: 185 x 72 x 42 mm (7.28 x 2.83 x 1.77 inch) |
| Item Device Description | Notes |
| 1 (Input Connector) | • Dimensions are in mm |
| 2 (Output Connector) | • For information on Mounting Torque, and I/O Connector and Housing, please refer to the Instruction Manual. |
| 3 (VR) | • For L Frame type: There are 6 threaded mounting holes and 5 normal mounting |
| 4 (Remote ON/OFF (JST B2B-XH-A)) | holes. |
| 5 (Chassis) | • For Open Frame type: There are 4 normal mounting holes. PJ Open Frame Power Supply 12 V 100 W 1 Phase / PJ-12V100W□□A Enclosed L x W x H: 185 x 72 x 42 mm (7.28 x 2.83 x 1.77 inch) |
| ■ Open Frame | ■ L Frame / Enclosed For safety reasons, please ensure the mounted device is kept safety distance as below at all sides from other components and equipments. a) For Open Frame Type ≥ 8 mm (0.315 inch) from primary side and ≥ 4 mm (0.16 inch) from secondary side. b) For with Case Type ≥ 4 mm (0.16 inch) Please insert an insulation sheet between the system and product, if the safety distance is less than 4 mm (0.16 inch). |
| Table 1 (Connector (Board Mounting)) | Housing Terminal |
| Input (JST) (B3P5-VH(LF)(SN)) | VHR-5N SVH-21T-P1.1 |
| Output (JST) (B8P-VH(LF)(SN)) | VHR-8N Remote ON/OFF Function |
| B2B-XH-A(LF)(SN) (XHP-2) | SXH-001T-P0.6 (Option) PJ Open Frame Power Supply 12 V 100 W 1 Phase / PJ-12V100W□□A Mounting Orientation damage the device’s PCB. Please handle the device with care. placed on low thermal conductive surfaces. For example, plastics. conductors from entering the device |
| through (the) | openings during installation. It may cause: -Electric shock; Safety hazard; Product failure. by metal screws onto a grounded |
| metal (surface.) | It is highly recommended that the Earth terminal on the connector be connected to the grounded metal surface. Engineering Data Convection Output Load De-rating VS Surrounding Air Temperature |
| (Open Frame / L Frame) | Enclosed |
| Fig.1.1 De-rating for Mounting Orientation A, B | Fig.1.2 De-rating for Mounting Orientation A, B |
| > 50°C de-rate power by 2.5% / °C | > 40°C de-rate power by 2.5% / °C |
| De-rating for Mounting Orientation C | De-rating for Mounting Orientation C |
| > 45°C de-rate power by 2% / °C | > 35°C de-rate power by 2% / °C |
| De-rating for Mounting Orientation D | De-rating for Mounting Orientation D, E |
| > 35°C de-rate power by 2% / °C | > 30°C de-rate power by 2% / °C |
| De-rating for Mounting Orientation E, F | De-rating for Mounting Orientation F |
| > 40°C de-rate power by 2% / °C | > 35°C de-rate power by 2.4% / °C PJ Open Frame Power Supply 12 V 100 W 1 Phase / PJ-12V100W□□A Forced Cooling (Air Velocity > 0.7 m/s) Output Load De-rating VS Surrounding Air Temperature |
| Fig.1.3 De-rating for Mounting Orientation A to F | Fig.1.4 De-rating for Mounting Orientation A to F |