| Series | LM150-20Bxx |
| Model | LM150-20B24 |
| Type | Enclosed Switching Power Supplies |
| Brand | MORNSUN |
| Input Voltage Range (AC) | 85–264 VAC |
| Input Voltage Range (DC) | 120–370 VDC |
| Input Voltage Frequency | 47–63 Hz; 115VAC: 4 Hz |
| Input Current | 230VAC: 2A max; 115VAC: 30A |
| Inrush Current | 60A @230VAC (Cold start) |
| Leakage Current | <0.75mA max @240VAC |
| Hot Plug | Unavailable |
| Output Voltage Accuracy | Normal temperature,: ±1%; high temperature: %; ±3%; Low temperature: % (Full load range) |
| Line Regulation | ±0.5% (Rated load) |
| Load Regulation | ±0.5%; 12V/15V: 150% (0% - 100% load; 20MHz bandwidth) |
| Ripple & Noise | mV; 24V/36V/48V: 200mV max ((peak-to-peak value)) |
| Temperature Coefficient | ±0.03%/℃ |
| Minimum Load | 0% |
| Stand-by Power Consumption | 0.5W; 115VAC: 8W |
| Hold-up Time | ms; 230VAC: 16 ms |
| Short Circuit Protection | Recovery time <5s after the short circuit clearance: Hiccup, continuous, self-recover turn; ≥110% Io, for more than 5 seconds, turn |
| Over-current Protection | off, self-recover after restarting Hiccup,; 12V: ≤18VDC Hiccup,; 15V: ≤21.75VDC Hiccup, |
| Over-voltage Protection | 24V: ≤33.6VDC–self-recover after; fault clearance; 36V: ≤48.6VDC; 48V: ≤60VDC |
| Over-temperature Protection | Output voltage turn off, self-recover |
| Isolation (Input–⏚) | 2000 VAC |
| Isolation (Input–Output) | 4000 VAC (Electric strength test for 1min., leakage current <10mA) |
| Isolation (Output–⏚) | 1250 VAC |
| Insulation Resistance | Input - output Test voltage: 500VDC: 100 MΩ; Output -: 100 MΩ |
| Operating Temperature | -30 to +70℃ |
| Storage Temperature | -40–+85℃ |
| Storage Humidity | 10–95 %RH; Non-condensing: %RH |
| Operating Humidity | 20–90 %RH |
| Switching Frequency | 65kHz; 85VAC-100VAC -30℃ to -25℃: 5; temperature 12V +45℃ to +70℃: 2 %/℃ (Operating) |
| Power Derating | 15V/24V/36V/48V +50℃ to +70℃: 2.5; Input voltage derating 85VAC-100VAC: 1.33 %/VAC; IS13252–safety approved; & EN60335-1,–EN61558-2-16, (derating) |
| Safety Standard | EN/BS EN62368-1(Report); Design refer to UL/IEC62368-1 |
| Safety Class | CLASS I |
| MTBF | >300,000 h (MIL-HDBK-217F@25℃) |
| Sinusoidal Vibration | IEC60068-2-6 typ, GB2423.10, min (10 - 500Hz, 5g, three directions of X, Y, Z axis) |
| Warranty | 3 years (Ambient temperature: <45℃) |
| Case Material | Metal (AL1100, SGCC) |
| Dimensions | 159.00 x 97.00 x 30.00mm |
| Weight | 410g (Typ.) |
| Cooling Method | Free air convection |
| EMC Emissions | CE: CISPR32/EN55032 CLASS B; RE: CISPR32/EN55032 CLASS B |
| EMC Immunity | Harmonic current: IEC/EN61000-3-2 CLASS A (≤80% Load); ESD: IEC/EN61000-4-2 Contact ±6KV/Air ±8KV (perf. Criteria A); RS: IEC/EN61000-4-3 10V/m (perf. Criteria A); EFT: IEC/EN61000-4-4 ±4KV (perf. Criteria A); Surge: IEC/EN61000-4-5 line to line ±2KV/line to PE ±4KV (perf. Criteria A); CS: IEC/EN61000-4-6 10Vr.m.s (perf. Criteria A); Voltage dip,: short interruption and IEC/EN61000-4-11 100% dip 1 periods, 30% dip 25 periods, |