| Series | LM100-20Bxx |
| Model | LM100-20B24 |
| Type | Enclosed Switching Power Supplies |
| Brand | MORNSUN |
| Input Voltage Range (AC) | 85–264 VAC |
| Input Voltage Range (DC) | 120–370 VDC |
| Input Voltage Frequency | 47–63 Hz; 115VAC: 3 Hz |
| Input Current | 230VAC: 1.5A max; 115VAC: 35A |
| Inrush Current | 65A @230VAC (Cold start) |
| Leakage Current | < typ, 0.75mA max @240VAC |
| Hot Plug | Unavailable |
| Output Voltage Accuracy | 5V: ±2%; 12V/15V/24V/36V/48V: ±1% (Full load range) |
| Line Regulation | Rated load: ±0.5%; 5V: ±1% |
| Load Regulation | 12V/15V/24V/36V/48V: ±0.5%; 5V: 100%; 12V/15V: 120% (0% - 100% load; 20MHz bandwidth) |
| Output Ripple & Noise | mV; 24V: 150mV; 36V/48V: 200mV ((peak-to-peak value)) |
| Temperature Coefficient | ±0.03%/℃ |
| Minimum Load | 0% |
| Stand-by Power Consumption | 230VAC: 0.5W; 115VAC: 10W typ, 5W min |
| Hold-up Time | ms; 230VAC: 55 ms typ, 45 ms min; ≥150% Io, constant current for more than 5; 5V, constant current for more than 5 seconds, turn off the: ms; seconds, turn off the output voltage, input; output voltage, input restart and restore: ms |
| Short Circuit Protection | restart and restore; Hiccup, continuous, self-recover; ≥110% Io, for more than 5 seconds, turn off (12V/15V/24V/36V/48V, recovery time < 5s after the short; circuit disappear.) |
| Over-current Protection | the output, power restart after recovery; 5V: ≤7.5VDC recovery; 12V: ≤19.2VDC recovery; 15V: ≤24VDC recovery |
| Over-voltage Protection | Hiccup, self-recover; 24V: ≤38.4VDC self-recover; 36V: ≤57.6VDC self-recover; 48V: ≤60VDC self-recover |
| Isolation | VAC (Electric strength test for 1min.,) |
| Isolation (Input–⏚) | 2000 VAC |
| Isolation (Input–Output) | 4000 VAC (24V/36V) |
| Isolation (Output–⏚) | 1250 VAC |
| Insulation Resistance | Input - output At 500VDC: 100 MΩ; Output -: 100 MΩ |
| Operating Temperature | -30 to +70℃ |
| Storage Temperature | -40–+85℃ |
| Storage Humidity | 10–95 %RH; Non-condensing: %RH |
| Operating Humidity | 20–90 %RH |
| Switching Frequency | 65kHz; 5V output +45℃ to +70℃: 1.6; Operating temperature: %/℃ |
| Power Derating | derating Other output +50℃ to +70℃: 2.0; Input voltage derating 85VAC-115VAC: 0.67 %/VAC; GB4943.1,–(Part1) safety approved; & EN60335-1,–EN61558-2-16, |
| Safety Standard | EN/BS EN62368-1(Report); Design refer to UL/IEC62368-1 |
| Safety Class | CLASS I |
| MTBF | >30,0000 h (MIL-HDBK-217F@25℃) |
| Warranty | 3 years (Ambient temperature: <70℃) |
| Case Material | Metal (AL1100, SGCC) |
| Dimension | 129.00 x 97.00 x 30.00mm; 5V 325g (Typ.) |
| Weight | 12V/15V/24V/36V/48V: 305g (Typ.) |
| Cooling Method | Free air convection |
| EMC Emissions | CE: CISPR32/EN55032 CLASS B; RE: CISPR32/EN55032 CLASS B |
| EMC Immunity | Harmonic current: IEC/EN61000-3-2 CLASS A; ESD: IEC/EN61000-4-2 Contact ±6KV/Air ±8KV (perf. Criteria A); RS: IEC/EN61000-4-3 10V/m (perf. Criteria A); EFT: IEC/EN61000-4-4 ±2KV (perf. Criteria A); Surge: IEC/EN61000-4-5 line to line ±2KV/line to PE ±4KV (perf. Criteria A); CS: IEC/EN61000-4-6 10 Vr.m.s (perf. Criteria A); Voltage dip, short: interruption and IEC/EN61000-4-11 100% dip 1 periods, 30% dip 25 periods, |