| Серия | DIN Pro |
| Модель | DRF-12V120W1PBA |
| Тип | Источники питания на DIN-рейке |
| Бренд | DELTA |
| Cover | Galvanized steel with organic coating |
| Chassis | Aluminum alloy with organic coating |
| Dimensions (H x W x D) | 124.2 x 30.0 x 117.1 mm (4.89 x 1.18 x 4.61 inch) |
| Indicator (Green LED) | DC OK |
| Cooling System | Convection |
| Terminal*4 (Output) | 3 Pins (Rated 600 V / 30 A) DC OK 4 Pins (Rated 300 V / 7 A) & Remote |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Noise (1 Meter from power supply) | Sound Pressure Level (SPL) < 25 dBA *4 The torque at the screw terminal connector shall not exceed 8.0 Kgf.cm. (7.0 lbf.in). Environment |
| Surrounding Air (Operating) | -40°C to +80°C |
| Temperature*5/6 | (Please refer to page 8 derating curve) |
| Storage | -40°C to +85°C |
| Power De-rating (Temperature) | > 60°C de-rate power by 2.5 % / °C, > 70°C de-rate power by 3.5% / °C |
| Voltage | < 200 Vdc de-rate power by 0.3% / Vdc |
| Рабочая влажность | 5 to 90% RH (Non-Condensing) |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft.) |
| Shock Test (Non-) | IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; |
| Operating | 3 times per direction, 9 times in total |
| Vibration (Non-) | IEC 60068-2-64, Random: 5 Hz to 500 Hz (2.09 G); |
| Over Voltage Category | II (Compliance to EN 61558-1 OVC III with 2000 meters altitude) *5 When operating at temperatures below -30°C, the PSU may require a few seconds to “bounce” before completing a cold-start power-up. *6 For power de-rating from 60°C to 80°C, refer power derating on page 8. DIN Pro Series DIN Rail Power Supply DRF-120W Series / DRF-V120W1PBA Protections |
| Overvoltage | <19 V, SELV Output, Hiccup <37 V, SELV Output, Hiccup <69 V, SELV Output, Hiccup |
| Mode, Auto-recovery (Mode, Auto-recovery) | Mode, Auto-recovery |
| Overload / Overcurrent | 125 - 205% of rated load current, Hiccup Mode, Auto-recovery (150% Power Boost for 5 seconds / 200% for 50ms / 500% for 5ms) |
| Over Temperature | Shut down, Auto-recovery |
| Короткое замыкание | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Protection Against Shock | Class I with PE*7 connection *7 PE: Primary Earth Reliability Data |
| MTBF (Telcordia) | > 700,000 hrs |
| Expected Cap Life Time | 10 Years (115 Vac & 230 Vac, 50% load @ 50°C) 5 Years (230 Vac, 80% load @ 50°C) |
| Warranty | 5 Years Safety Standards / Directives |
| Electrical Safety (CB scheme) | IEC/EN/BS EN 62368-1, AS/NZS 62368-1 RCM, IEC/EN 61010-1/2-201, IEC 61558-1/2-16, AS/NZS 61558-1/2-16 RCM |
| TUV Bauart | EN 62368-1 |
| UL/cUL | UL 62368-1, CSA C22.2; UL 61010-1/-2-201, CAN/CSA-C22.2 No. 61010-1-12 |
| CCC | GB4943.1 |
| BIS | IS 13252-1 (Part 1) |
| BSMI | CNS 15598-1 |
| EAC | TP TC 004/2011 |
| KC | KC 62368-1 (upon request) |
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| UKCA | In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091 |
| SELV | IEC/EN 62368-1 /61010-2-201 /61558-2-16 Input to 4.0 kVac Output Input to 2.5 kVac Ground |
| Galvanic Isolation | Output to 1.5 kVac Ground Output to 500 Vac DC OK DIN Pro Series DIN Rail Power Supply DRF-120W Series / DRF-V120W1PBA EMC*8 |
| Emissions (CE & RE) | CISPR 32, EN/BS EN 55032, AS/NZS CISPR 32, Class B; KS C 9832; CNS15936; EN/BS EN 61204-3; Compliance to FCC Title 47 |
| Immunity | EN/BS EN 55035; KS C 9835; EN/BS EN 61204-3 |
| Electrostatic (IEC 61000-4-2) | Level 4 Criteria A1) |
| Discharge | Air Discharge: 15 kV Contact Discharge: 8 kV |
| Radiated Field (IEC 61000-4-3) | Criteria A1) 80 MHz – 1 GHz, 10 V/M, 80% Modulation (1 kHz) 1.4 GHz – 6 GHz, 3 V/M, 80% Modulation (1 kHz) 2 GHz – 2.7 GHz, 1 V/M, 80% Modulation (1 kHz) |
| Electrical Fast (IEC 61000-4-4) | Level 4 Criteria A1) |
| Transient / Burst | 4 kV |
| Surge (IEC 61000-4-5) | Level 4 Criteria A1) |
| Condition | W/O SPD |
| Common Mode4) | 4 kV |
| Differential Mode5) | 2 kV |
| Conducted (IEC 61000-4-6) | Level 3 Criteria A1) 150 kHz – 80 MHz, 20 Vrms |
| Power Frequency (IEC 61000-4-8) | Level 4 Criteria A1) |
| Magnetic Fields | 30 A/m |
| Voltage Dips and (IEC 61000-4-11) | 0% residual; 1 cycle, Criteria B2) |
| Interruptions | 40% residual; 10 cycle, Criteria B3) 70% residual; 25 cycle, Criteria B3) Harmonic Current |
| Emission | IEC/EN/BS EN 61000-3-2, Class A Voltage Fluctuation |
| and Flicker | IEC/EN/BS EN 61000-3-3, dmax ≤ 4% |
| Voltage Sag (80% of 200 Vac) | 160 Vac, 1000 ms Criteria A1) |
| Immunity (70% of 200 Vac) | 140 Vac, 500 ms Criteria A1) |