| Série | LMBT10K-16B15B(F)R2 |
| Modelo | LMBT10K-16B15FR2 |
| Marca | MORNSUN |
| Faixa de tensão de entrada (CA) | 304–456 VAC |
| Input Voltage Frequency | 45–65 Hz |
| Corrente de entrada | 24A max @380VAC |
| Inrush Current (Cold Start) | 380VAC: 25A max |
| Fator de potência | 0.99 @380VAC, full load, 25℃ |
| Conexão a quente | Unavailable |
| Current Harmonic | 3% typ, TYP max @380VAC, full load |
| Input Under-voltage Protection | 277–295 VAC (Line voltage) (Full load range) |
| Input Over-voltage Protection | 470–485 %Vo (Line voltage) (Full load range) |
| Input Frequency Protection | Available (Full input range) (full load range) |
| Precisão da tensão de saída | ±1.0% (15V) (Full load range) |
| Regulação de linha | ±1.0% (Rated load) |
| Regulação de carga | ±1.0% (Rated input voltage 15V) (20MHz bandwidth; 25℃) |
| Ondulação e ruído | 15V: 300mV max; mV (peak-to-peak value) |
| Coeficiente de temperatura | ±0.03%/℃ |
| Minimum Load | 0%; Supports up to 4 parallel power supplies, CAN1 or CAN2 are: % |
| Load Sharing Accuracy | ±5.0%; interconnected: % |
| Proteção contra curto-circuito | Hiccup protection, self-recover; Hiccup protection, |
| Proteção contra sobrecorrente | Io, 500ms typ, ≥103% min self-recover; ≤18VDC, turn off the output, |
| Proteção contra sobretensão | 15V: off,; restore after restart off,; Output voltage turn off, |
| Proteção contra sobretemperatura | self-recover after the temperature drops; OTP temperature: 55℃ drops |
| Resistência de isolamento | Input -: 100 MΩ; Ambient temperature: 25 ± 5℃: MΩ; Input - output Relative humidity: < 95%RH, no condensation: 100 MΩ; Test voltage: 500VDC: MΩ; Output -: 100 MΩ; Input -: 2828 MΩ |
| Insulation Voltage | Input - output Electric strength test for 1min, leakage current <5mA: 4242 VDC; Output -: 707 VDC |
| Temperatura de operação | -10 to +60℃ |
| Temperatura de armazenamento | -40–+85℃ |
| Umidade de operação | 20–90 %RH; Non-condensing: %RH |
| Umidade de armazenamento | 10–95%/℃; -10℃ to +45℃: 0 %/℃; Operating temperature derating +45℃ to +55℃: 1 %/℃ |
| Power Derating | +55℃ to +60℃: 2 %/VAC; Input voltage derating 343VAC to 456VAC: 0 %/VAC; 304VAC to 343VAC: 0.5 %/VAC; Fault: Red %/VAC |
| Indicator Status | AC/DC forward Charging: Blue; DC/AC reverse inversion: Green |
| Bidirectional Switching Time | Seamless switching |
| Communication | CAN |
| Fan Fault protect | Self-recovery after fault clearance |
| Fan Speed Measurement | Intelligent speed regulation (Forced cooling) |
| Online upgrade Function | Available |
| Classe de segurança | CLASS I |
| Material do invólucro | Metal (SGCC) |
| Dimensões | 285.00mm x 218.00mm x 86.00mm |
| Peso | 5250g (Typ.) |
| Cooling Method* | Forced cooling |
| Imunidade EMC | Harmonic current: CLASS A; ESD: IEC61000-6-2/IEC61000-4-2 Contact ±6KV/Air ±8KV (Perf. Criteria A); RS: IEC61000-6-2/IEC61000-4-3 80MHz – 1GHz 10V/m (Perf. Criteria A); EFT: IEC61000-6-2/IEC61000-4-4 AC Port:±4kV , 100kHz (Perf. Criteria B); Surge: IEC61000-6-2/IEC61000-4-5 line to line ±2KV/line to ground (±4KV Perf. Criteria B); CS: IEC61000-6-2/IEC61000-4-6 0.15MHz-80MHz 10V r.m.s (Perf. Criteria A) |