| Série | LM350-12D3012-40 |
| Modelo | LM350-12D3012-40 |
| Marca | MORNSUN |
| Input Voltage Range (Rated) | 200–240 VAC |
| Faixa de tensão de entrada (CA) | 176–285 |
| Faixa de tensão de entrada (CC) | 240–400 VDC |
| Input Voltage Frequency | Hz; AC input: 47–63 Hz; Rated input (Certified voltage): 6 Hz |
| Corrente de entrada | 6A max @230VAC |
| Inrush Current (Cold Start) | 230VAC: 30A typ, 35A max |
| Start-up Delay Time | 1.5 s @230VAC, rated load |
| Input Fuse | Built-in fuse: 12.5A; Under-voltage protection start (Input voltage drops: A; 145–165 A; from high to low), each output with 50% Io: A |
| Input Under-voltage Protection | VAC; Under-voltage protection release (Input voltage: VAC; 160–175 VAC; rises from low to high), each output with 50% Io: VAC |
| Conexão a quente | Unavailable |
| Precisão da tensão de saída | Vo1: ±1.5% typ, ±2% max; %; Vo2: ±1.5% typ, ±3% max; Vo1: ±1% (Full load range) |
| Regulação de linha | Rated load: %; Vo2: ±2%; Vo1: ±1% |
| Regulação de carga | ±2% (Vo2) (0% - 100% load) |
| Minimum Load | 0; Vo1: 200 (20MHz bandwidth) |
| Ondulação e ruído | mV; (peak-peak value) Vo2: 150mV typ, 240mV max |
| Coeficiente de temperatura | ±0.02%/℃ |
| Tempo de retenção | 230VAC, rated load: 15 ms; Hiccup, continuous, self-recover ms |
| Proteção contra curto-circuito | (12V does not affect 30V); <200VAC: ≥110% Io, hiccup, self-recover (Recovery time <3s after the short circuit disappear.) |
| Proteção contra sobrecorrente | ≥130% Io, hiccup, self-recover @≥200VAC |
| Proteção contra sobretensão | Vo1: ≤40VDC (Hiccup, self-recover) over-temperature; hiccup, self-recover after over-temperature |
| Proteção contra sobretemperatura | fault elimination |
| Isolation (Input–⏚) | 1500 VAC |
| Isolamento | VAC (Electric strength test for 1min., leakage current <5mA) |
| Isolamento (entrada–saída) | 3000 VAC (* Input - output (Before testing the isolation and insulation resistance,) |
| Isolation (Output–⏚) | 500 VAC (remove the φ4 screw ①)) |
| Resistência de isolamento | Input - output Relative humidity: < 95%RH, no condensation: 100 MΩ; Test voltage: 500VDC: MΩ; Output -: 100 MΩ |
| Temperatura de operação | -40 to +85℃ |
| Temperatura de armazenamento | -45–+85℃ |
| Umidade de operação | 95 %RH; Non-condensing: %RH |
| Umidade de armazenamento | 95 %/℃; -40℃ to -25℃: 2.67 %/℃; Operating temperature: %/℃; derating (Without +55℃ to +70℃: 3.33 %/℃ |
| Power Derating | aluminum plate): ℃/Km; +70℃ to +85℃: 1.33 ℃/Km; Altitude derating 2000m - 3000m: 5 ℃/Km; Input -: ≤3.5mA ℃/Km |
| Corrente de fuga | ≤0.25mA max (Input - output) (240VAC, 60Hz) |
| Normas de segurança | Design refer to EN62368-1, GB4943.1 |
| Classe de segurança | CLASS I |
| MTBF | ≥300,000 h (MIL-HDBK-217F@25℃) |
| Warranty | 3 years (Ambient temperature: <85℃) |
| Emissões EMC | CE (Input: port) CISPR32/EN55032 150K - 30MHz (CLASS A); RE: CISPR32/EN55032 30MHz - 1GHz (CLASS A) |
| Imunidade EMC | Voltage: flicker EN61000-3-3 (--); ESD: IEC/EN61000-4-2 Contact ±8KV/Air ±8KV (perf. Criteria A); RS: IEC/EN61000-4-3 3V/m (perf. Criteria A); EFT (Input: port) IEC/EN61000-4-4 ±2KV (perf. Criteria A); Surge (Input: port); CS: IEC/EN61000-4-6 0.15 - 80MHz, 3Vr.m.s (perf. Criteria A); Voltage: variation* IEC61000-6-2/IEC61000-4-11 40% Un, 10/12 cycle(50/60Hz) (perf. Criteria A); Voltage: interruption* IEC61000-6-2/IEC61000-4-11 0% Un, 250/300 cycle(50/60Hz) (perf. Criteria A) |