| Série | LI60-20BxxPR3 |
| Modelo | LI60-20B24PR3 |
| Marca | MORNSUN |
| Faixa de tensão de entrada (CA) | 85–264 VAC |
| Faixa de tensão de entrada (CC) | 120–370 VDC |
| Input Frequency | 47–63 Hz; 115VAC: 1.2 Hz |
| Corrente de entrada | 230VAC: 0.8A max; 115VAC: 30A typ, 38A max |
| Corrente de partida | 60A typ, 78A max @230VAC |
| Corrente de fuga | 0.25mA typ, RMS max. max @264VAC |
| Conexão a quente | Unavailable |
| Precisão da tensão de saída | 5V: ±2%; %; 12V/15V/24V/48V: ±1% (0% - 100% load) |
| Regulação de linha | Rated load: ±0.5%; 5V: ±1.5% |
| Regulação de carga | 12V/15V/24V/48V: ±1.0%; 5V: 80%; 12V/15V: 120% (230VAC; 20MHz bandwidth) |
| Output Ripple & Noise | mV; 24V: 150mV max; 48V: 240mV max ((peak-to-peak value)) |
| Coeficiente de temperatura | ±0.02%/°C; 5V/12V/15V/24V: 0.3%/°C |
| Stand-by Power Consumption | 230VAC input: W; 48V: 0.4W |
| Proteção contra curto-circuito | Hiccup, continuous, self-recovery; ≥110% Io, self-recovery; Belch or constant current mode when output; voltage < 50% or constant current mode when |
| Proteção contra sobrecorrente | output voltage < 50% removal; When the output voltage is 50%-100%, it is in constant; current mode, and the load abnormal condition can; be automatically restored after removal; 5V: ≤7.5V removal; 12V: ≤16V removal |
| Proteção contra sobretensão | 15V: ≤22.5V Output voltage hiccup; 24V: ≤36V; 48V: ≤60V |
| Minimum Load | 0% |
| Start-up Time | 1 s; 115VAC: 15 s |
| Tempo de retenção | ms; 230VAC: 80 ms |
| Isolamento | VAC (Electric Strength Test for 1min.,) |
| Isolamento (entrada–saída) | 4000 VAC |
| Resistência de isolamento | Input - output Test voltage: 500VDC: 100 MΩ |
| Temperatura de operação | -40 to +85℃ |
| Temperatura de armazenamento | -40–+85℃ |
| Umidade de armazenamento | 95 %RH; Non-condensing: %RH |
| Umidade de operação | 90 %RH |
| Altitude | 5000 m; Other output: 3.0; -40℃ to -30℃ 24V: 7.0; temperature 15V: 8.0 %/℃ (Operating) |
| Output Power Derating | derating: %/VAC; +45℃ to +70℃: 2.0 %/VAC; +70℃ to +85℃: 2.0 %/VAC; Input voltage: %/VAC; 85VAC - 100VAC: 1.0 %/VAC; derating: %/VAC; Design refer to UL/EN/BS EN62368-1, UL508, %/VAC |
| Safety Standard | EN60335-1; –EN62477 |
| Classe de segurança | Class I (peripheralize), Class II (no perimeter required) |
| MTBF | > 300,000 h (MIL-HDBK-217F@25°C) |
| Material do invólucro | Plastic, heat-resistant (UL94V-0) |
| Package Dimensions | 92.66 x 52.00 x 58.00mm |
| Peso | 180g (Typ.) |
| Método de refrigeração | Free air convection |
| Emissões EMC | CE: CISPR32/EN55032 CLASS B; RE: CISPR32/EN55032 CLASS B |
| Imunidade EMC | Harmonic current: IEC/EN61000-3-2 CLASS A; Voltage flicker: IEC/EN61000-3-3; ESD: IEC/EN61000-4-2 Contact ±6KV/Air ±8KV (Perf. Criteria A A); RS: IEC/EN61000-4-3 10V/m (Perf. Criteria A); ; Surge: IEC/EN61000-4-5 Line to PE ±4KV; CS: IEC/EN61000-4-6 10Vr.m.s (Perf. Criteria A); PFMF: IEC/EN61000-4-8 30A/m (Perf. Criteria A); Voltage Variations *: IEC61000-6-2/IEC61000-4-11 40% U ,10/12cycle(50/60Hz); (Perf. Criteria B) |