| Series | CHROME II |
| Model | DRC-05V015W1RZ |
| Type | DIN-Rail Power Supplies |
| Brand | DELTA |
| Case Cover | Plastic |
| Dimensions (H x W x D) | 87.5 x 18.0 x 55.0 mm (3.45 x 0.7 x 2.17 inch) |
| Indicator (Green LED) | DC OK |
| Cooling System | Convection |
| Terminal *4 (Input) | M2.5 x 2 Pins (Rated 300 V / 16 A) |
| Wire (Input) | AWG 26-12 |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Noise (1 Meter from power supply) | Sound Pressure Level (SPL) < 25 dBA *4 The torque at the terminal connector shall not exceed 4 Kgf.cm. (3.5 lbf.in). Environment |
| Surrounding Air (Operating) | -40°C to +70°C |
| Temperature (Storage) | -40°C to +85°C |
| Power De-rating (Temperature) | > 50°C de-rate power by 2% / °C |
| Voltage | < 142 Vdc de-rate power by 1% / Vdc |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft) |
| Shock Test (Non-) | IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; |
| Operating | 3 times per direction |
| Vibration | IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz @ 2 G; 10 min per cycle, |
| Over Voltage Category | II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) Chrome II DIN Rail Power Supply DRC-15W Series (Class II & NEC Class 2) / DRC-V015W1RZ Protections |
| Overvoltage (< 7.5 V, SELV Output) | < 18 V, SELV Output < 36 V, SELV Output |
| Auto Mode (Auto Mode) | Auto Mode |
| Overload / Overcurrent | 101 - 150% of rated load current, Auto-recovery Continuous current limit Mode*5 (Vo > 80%) |
| Over Temperature | Auto Mode |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Internal Fuse at L pin | T3.15A / 250V |
| Degree of Protection | IP20 |
| Protection Against Shock | Class II (No PE* 6 connection is required) *5 Constant current limit protection for inductive and capacitive load applications *6 PE: Primary Earth Reliability Data |
| MTBF (Telcordia) | > 700,000 hrs |
| Expected Cap Life Time | 10 years (115 Vac & 230 Vac, 50% load @ 40°C) Saf ety Standards / Directives |
| Electrical Safety (CB scheme) | IEC 62368-1, IEC/EN/BS 61010-1/-2-201, IEC 60335-1, IEC/EN/BS 61558-1/-2-16 |
| TUV Bauart | EN/BS 62368-1 |
| UL/cUL | UL 62368-1, UL 61010-1/-2-201 |
| EAC | TP TC 004/2011 |
| BSMI | CNS 15598-1 |
| BIS | IS 13252 (Part 1) |
| CCC | GB 4943.1 UL/cUL |
| Class 2 Power Supply | UL 62368-1 and CSA C22.2 No. 62368-1 recognized |
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| UKCA | In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016 |
| Galvanic Isolation (Input to Output) | 4.0 kVac Chrome II DIN Rail Power Supply DRC-15W Series (Class II & NEC Class 2) / DRC-V015W1RZ EMC |
| Emissions (CE & RE) | CISPR 32, EN/BS 55032, AS/NZS CISPR32, EN 61204-3, KS C 9832 Compliance to FCC Title 47, EN/BS 61000-6-3, EN/BS EN 61000-6-4: Class B |
| Component Power Supply for General | EN 61204-3 Use |
| Immunity | EN/BS 55035, KS C 9835, EN/BS 61000-6-2 Compliance to EN 61000-6-1 |
| Electrostatic (IEC 61000-4-2) | Level 4 Criteria A1) |
| Discharge | Air Discharge: 15 kV Contact Discharge: 8 kV |
| Radiated Field (IEC 61000-4-3) | Criteria A1) 80 MHz – 1 GHz, 10 V/M, 80% Modulation (1 kHz) 1.4 GHz – 2 GHz, 3 V/M, 80% Modulation (1 kHz) 2 GHz – 2.7 GHz, 1 V/M, 80% Modulation (1 kHz) |
| Electrical Fast (IEC 61000-4-4) | Level 3 Criteria A1) |
| Transient / Burst | 2 kV |
| Surge (IEC 61000-4-5) | Level 4 Criteria A1) Differential Mode 4): 2 kV |
| Conducted (IEC 61000-4-6) | Level 3 Criteria A1) 150 kHz – 80 MHz, 10 Vrms |
| Power Frequency IEC 61000-4-8 | Level 4 Criteria A1) |
| Magnetic Fields | 30 A/m |
| Voltage Dips and IEC 61000-4-11 | 0% residual; 1 cycle, Criteria B 2) |
| Interruptions | 40% residual; 10 cycle, Criteria C 3) 70% residual; 25 cycle, Criteria C 3) |
| Harmonic Current | IEC/EN 61000-3-2, Class A Emission |
| Voltage Fluctuation and | IEC/EN 61000-3-3 Flicker |
| Voltage Sag Immunity | 80% of 200 Vac, 160 Vac for 1000 ms, Criteria A1) |
| SEMI F47 – 0706 | 70% of 200 Vac, 140 Vac for 500 ms, Criteria A1) 50% of 200 Vac, 100 Vac for 200 ms, Criteria A1) 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Temporary degradation or loss of function which is self -recoverable 3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test) 4) Symmetrical: Differential mode (Line to line) |
| 1) | Input terminal block connector |
| 2) | Output terminal block connector |
| 3) | DC voltage adjustment potentiometer |