| Serie | LMF600-20Bxx |
| Modell | LMF600-20B27 |
| Marke | MORNSUN |
| Eingangsspannungsbereich (AC) | 80–277 VAC |
| Eingangsspannungsbereich (DC) | 110–390 VDC |
| Input Voltage Frequency | 47–63 Hz; 115VAC: 7.5 Hz |
| Eingangsstrom | 3.5A max @230VAC |
| Inrush Current (Cold Start) | 115VAC/230VAC: 15A max; 115VAC: 0.99A |
| Leistungsfaktor | 0.99 @230VAC (Full load) |
| Ableitstrom | <0.1mA @240VAC |
| Hot-Plug | Unavailable |
| Ausgangsspannungsgenauigkeit | 12V/15V/24V/27V/36V/48V: ±1%; 5V Standby: ±2%; 12V/15V/24V/27V/36V/48V: ±0.3% (Full load range) |
| Netzregelung | Rated load: %; 5V Standby: ±0.5%; 12V/15V/24V/27V/36V/48V: ±0.5% |
| Lastregelung | 5V Standby: ±2%; 12V/15V: 150% (0% - 100% load; 20MHz bandwidth) |
| Restwelligkeit und Rauschen | mV; 24V/27V/36V/48V: 200mV ((peak-to-peak value)) |
| Minimum Load | 0% |
| Stand-by Power Consumption | 0.5W @Room temperature, 230VAC, RC+/RC- add +5V signal |
| Überbrückungszeit | 230VAC: 15 ms; Hiccup mode, constant current works 1s, turn off |
| Kurzschlussschutz | 10s, continuous, self-recover; 110% - 250% Io, the output turned off after (Recovery time 10s after the short circuit disappear.) |
| Überstromschutz | working normally for 1s, self-recover; 12V: ≤16VDC (Hiccup, self-recover); 15V: ≤20VDC (Hiccup, self-recover); 24V: ≤32VDC (Hiccup, self-recover) |
| Überspannungsschutz | 27V: ≤35VDC (Hiccup, self-recover); 36V: ≤47VDC (Hiccup, self-recover); 48V: ≤60VDC (Hiccup, self-recover); Output voltage turn off, self-recover after the |
| Übertemperaturschutz | temperature drops. |
| Isolation (Input–⏚) | 1500 VAC |
| Isolation (Eingang–Ausgang) | 4000 VAC (Electric strength test for 1min., leakage current <5mA) |
| Isolation (Output–⏚) | 1500 VAC |
| Isolation | VAC (Environment temperature: 25 ± 5℃) |
| Insulation Resistance Isolation | Input - output Relative humidity: <95%RH, non-condensing: 50 MΩ; Testing voltage: 500VDC: MΩ; Output -: 50 MΩ; Input - output: 2 × MOPP MΩ; level Input -: 1 × MOPP MΩ |
| Betriebstemperatur | -40 to 70℃ |
| Lagertemperatur | -40–85℃ |
| Betriebsfeuchtigkeit | 20–95 %RH; Non-condensing: %RH |
| Lagerfeuchtigkeit | 10–95%/℃; Operating temperature derating +50℃ to +70℃: 2.5 %/℃ |
| Power Derating | 80VAC-85VAC: 2.0; Input voltage derating: %/VAC; 85VAC-100VAC: 1.33; GB4943.1, IEC60601-1 safety approved &; EN60601-1,–EN62368-1 |
| Safety Standard | Design refer to IEC/UL62368-1; EN61558-2-16; EN60335-1 typ; EN61558-1; min |
| MTBF | >300,000 h (MIL-HDBK-217F@25℃) |
| Gehäusematerial | Metal (AL1100, SGCC) |
| Abmessungen | 101.60mm x 203.10mm x 40.60mm |
| Gewicht | 950g (Typ.) |
| Kühlmethode | Forced air convection |
| EMV-Emissionen | CE: CISPR32/EN55032 CLASS B; RE: CISPR32/EN55032 CLASS B |
| EMV-Störfestigkeit | ESD: IEC/EN 61000-4-2 Contact ±8KV/Air ±15KV (perf. Criteria A); RS: IEC/EN 61000-4-3 10V/m (perf. Criteria A); EFT: IEC/EN 61000-4-4 ±4KV (perf. Criteria A); CS: IEC/EN61000-4-6 10 Vr.m.s (perf. Criteria A) |