| Input Voltage Range (Rated) | 100–240 VAC |
| Eingangsspannungsbereich (AC) | 85–277 |
| Eingangsspannungsbereich (DC) | 120–390 VDC |
| Maximum Input Voltage | 305 VAC (Lasts for 2h without damage) |
| Input Voltage Frequency | 47–63 Hz; 115VAC: 6 Hz |
| Eingangsstrom | 230VAC: 2.5A max; 115VAC: 15A max |
| Inrush Current (Cold Start) | 230VAC: 35 A²s max; A²s; 115VAC: 0.2 A²s |
| Inrush Current Integral (I²t) | 230VAC: 0.8A; 115VAC: 0.98A |
| Leistungsfaktor | 0.96 @230VAC (Rated load) |
| THD | 7% @115VAC, rated load |
| Start-up Delay Time | 400 ms; 115VAC/230VAC, rated load: ms |
| Rise Time | 40 |
| Input Fuse | 8A (Built-in fuse) |
| DC OK Signal | 30VDC/1A typ, Max. max (Resistive load) |
| Hot-Plug | Unavailable |
| Ausgangsspannungsgenauigkeit | ±1.0% (Full load range) |
| Netzregelung | ±0.25% (Rated load) |
| Lastregelung | ±0.5% (0% - 100% load) |
| Power Consumption | 25.5W @230VAC, rated load |
| Restwelligkeit und Rauschen | 120mV max (peak-to-peak value) (20MHz bandwidth) |
| Überbrückungszeit | 115VAC/230VAC: 18 ms; Operation voltage: 21.6 ms |
| DC OK Relay | V; Release voltage: 19.2V |
| Kurzschlussschutz | Constant current: 115–140%; 110% - 140% Io (typ. 120%Io, constant current, |
| Überstromschutz | self-recover) (115VAC/230VAC) |
| Überspannungsschutz | <35VDC (Output-off or clamping, self-recover); 230VAC, Over-temperature protection start: 95 self-recover) |
| Übertemperaturschutz | ℃; rated load: 60℃; Over-temperature protection release: ℃ |
| Isolation (Input–⏚) | 2500 VAC |
| Isolation (Eingang–Ausgang) | 4000 VAC (test for 1min., leakage current <5mA) |
| Test | 1500 (Output -) (Input -; Environment temperature: 25±5℃) |
| Isolationswiderstand | Input - output Relative humidity: <95%, Non-condensing: 50 MΩ; Test voltage: 500VDC: MΩ; Output -: MΩ |
| Betriebstemperatur | -40 to +85℃ |
| Lagertemperatur | -40–+85℃ |
| Betriebsfeuchtigkeit | 10–95 %RH; Non-condensing: %RH |
| Lagerfeuchtigkeit | 20–90 %RH; PFC: 58–77 %RH |
| Schaltfrequenz | kHz; DC-DC: 40–130; -40℃ to -30℃: 2; -30℃ to +60℃: 0; +60℃ to +80℃: 3.75 %/℃ (Operating temperature; derating @AC input) |
| Power Derating | -40℃ to -30℃: 2; -30℃ to +40℃: 0; +40℃ to +80℃: 2; Input voltage derating 85VAC - 100VAC: 1 %/VAC; 100VAC - 277VAC: 0; 120VDC - 140VDC: 1 %/VDC; 140VDC - 390VDC: 0 (Operating temperature; derating @DC input) |
| Ableitstrom | 240VAC, 60Hz: <1.5mA max 62368-1,; Design refer to IEC/EN/UL/BS EN 62368-1, |
| Safety Standard | UL508 typ; UL61010-1; min |
| Schutzklasse | CLASS I; MIL-HDBK-217F@25℃: >702,000h |
| MTBF | >504,000h (MIL-HDBK-217F@40℃) |
| Warranty | 5 years (Ambient temperature: <40℃) |
| High and Low Voltage Crossing | 31111-2017 typ, NB/T min (It needs to be used with UPS test ot our company) |
| Gehäusematerial | Metall(AL5052, SUS304) |
| Abmessungen | 124.00 ×55.00 × 127.00mm |
| Gewicht | 985g (Typ.) |
| Kühlmethode | Free air convection |
| EMV-Emissionen | CE (Input port): CISPR32 EN55032 150K - 30MHz (CLASS B); RE: CISPR32 EN55032 30MHz - 2GHz (CLASS B) |
| EMV-Störfestigkeit | Harmonic current: IEC/EN61000-3-2 (CLASS A and CLASS D); Voltage flicker: EN61000-3-3 (Fulfilled); ESD: IEC/EN61000-4-2 Contact1±8KV/Air ±15KV; RS: IEC/EN61000-4-3 20V/m; ; ; CS: IEC/EN61000-4-6 0.15 - 80MHz 20Vr.m.s; Harmonic and: network signal IEC61000-4-13 CLASS 3; PFMF: IEC/EN61000-4-8 30A/m; Voltage dips: IEC/EN61000-4-11; Voltage interruption: IEC/EN61000-4-11 0% U ,250/300 cycle(50/60Hz) (perf. Criteria C) |