| Série | PMS |
| Modelo | PMS-12V2K5W1BTD |
| Tipo | Fontes de alimentação comutadas fechadas |
| Marca | DELTA |
| Case Chassis | SGCC |
| Case Cover | SGCC |
| Dimensions (L x W x H) | 271 x 127.0 x 40.5 mm (10.67 x 5 x 1.59 inch)*7 |
| Cooling System | Force Cooling M3.5 x 3 Pins, CN1 / AC Input |
| Terminal | M6 x 2 Pins, CN101 / DC Output *7 Exclude Busbar terminal Environment |
| Surrounding Air (Operating) | -20°C to +70°C |
| Temperature (Storage) | -40°C to +85°C |
| Temperature | > 50°C de-rate power by 2.5% / °C |
| Power De-rating | 132-180 Vac, de-rate power by 0.83% / Vac from 2,500 W to 1,500 W @ 132 Vac |
| Umidade de operação | 5-95% RH (Non-Condensing) |
| Operating Altitude | 0 to 5,000 Meters (0 to 16,400 ft) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction IEC 60068-2-6, Sine Wave: 5 Hz to 500 Hz @ 2G;10 Min per cycle,60min for X, Y, Z |
| Vibração | Operating direction |
| Acoustic Noise*8 (Tolerance: ±2dB) | < 45dB @ 80% load @ 25°C *8 Acoustic Noise test set up according to ISO-7779 |
| Fig 1. | Acoustic Noise Testing Set Up PMS Panel Mount Power Supply PMS 2,500 W series / PMS-□V2K5W1BTD Protections Main output 145% max of rated normal voltage, Latch Mode Overvoltage Standby 125% max of rated voltage, Latch Mode Main output 130% max of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) Overload / Overcurrent Standby 3.2A max with Hiccup Mode (Non-Latching, Auto-Recovery) |
| Over Temperature | Auto-Recovery Hiccup Mode to Main output / Standby Short Circuit (Non-Latching, Auto-Recovery when the fault is removed) |
| Protection Against Shock | Class I with PE*9 connection *9 PE: Protection Earth Reliability Data 500K hrs based on Telcordia SR-332 MTBF (@ 230 Vac, 100% Load, 35°C) |
| Expected Cap Life Time | 5 years, (@ 230 Vac, 100% load @ 25°C) Safety Standards / Directives |
| Safety Entry Low Voltage | SELV |
| TUV Bauart | EN 62368-1 |
| UL/cUL | UL 62368-1, and CAN/CSA C22.2 No. 62368-1 |
| Electrical Safety (CB scheme) | IEC 62368-1 |
| CQC | GB 4943.1 |
| BIS | IS 13252(part 1) *10 |
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical |
| UKCA | Equipment (Safety) Regulations 2016 |
| Input to Output | 4.0 KVac |
| Galvanic Isolation (Input to Ground) | 2.0 KVac |
| Output to Ground | 1.5 KVac *10 24/48V only PMS Panel Mount Power Supply PMS 2,500 W series / PMS-□V2K5W1BTD EMC |
| Emissions (CE & RE) | EN 55032, KS C 9832, Comply to FCC Title 47: Class B Level 4 Criteria A 1) Electrostatic |
| IEC 61000-4-2 | Air Discharge: 15 kV Discharge Contact Discharge: 8 kV Criteria A 1) 80MHz-2700MHz, 10V/m AM modulation |
| Radiated Field | IEC 61000-4-3 Level 2 Criteria A 1)5) 385MHz-5785MHz, 28V/m Pulse mode and other modulation |
| Electrical Fast | Level 3 Criteria A 1) IEC 61000-4-4 |
| Transient / Burst | 2kV Level 3 Criteria A 1)5) |
| Surge (IEC 61000-4-5) | Common Mode 3): 2 kV Differential Mode 4): 1 kV Level 2 Criteria A 1)5) |
| Conducted | IEC 61000-4-6 150kHz-80MHz, 3Vrms, 6Vrms at ISM bands and Amateur radio bands |
| Power Frequency | Criteria A 1)5) IEC 61000-4-8 |
| Magnetic Fields | Magnetic field strength 30A/m 30% 10ms Criteria A 1) Voltage Dips and |
| IEC 61000-4-11 | 60% 100ms Criteria B 2) Interruptions 100% 5000ms Criteria B 2) Harmonic Current |
| IEC/EN 61000-3-2 | Meet Class A limit Emission |
| Voltage Fluctuation and Flicker | EN 61000-3-3 80% of 200 Vac, 160 Vac, 1000 ms, Criteria A1) Voltage Sag Immunity 70% of 200 Vac, 140 Vac, 500 ms, Criteria A1) @ 1,900W & Criteria B2) @ 2,500W SEMI F47 – 0706 50% of 200 Vac, 100 Vac, 200 ms, Criteria A1) @ 1,900W & Criteria B2) @ 2,500W 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test. |
| 1) | Output terminal block connector |
| 2) | Input terminal block connector |
| 3) | DC voltage adjustment potentiometer |
| 4) | Communications Connector |
| 5) | Global Control Signals PMS Panel Mount Power Supply PMS 2,500 W series / PMS-□V2K5W1BTD Dimensions L x W x H: 271 x 127.0 x 40.5 mm (10.67 x 5 x 1.59 inch) Notes: 1. Base plate mounting, M4 thread holes, maximum penetration 3.0mm (0.118 inch) from outside face of chassis, maximum torque 9- 10 kgf.cm (7.82-8.69 lbf.in). 2. Side mounting, M4 thread holes, maximum penetration 3.0mm (0.118inch) from outside face of chassis, maximum torque 9-10 |
| Pin 1 | Earth |
| Pin 2 | Line |
| Pin 3 | Neutral Output Connector CN101 |
| V+ | Output |
| Pin 4 | Serial clock signal (SCL) |
| Pin 5 | NC |
| Pin 6 | NC |
| Pin 7 | Address bit 0 (A0) |
| Pin 8 | Address bit 1 (A1) |
| Pin 9 | Address bit 2 (A2) |
| Pin 10 | NC Control Connector CN602(Molex:87833-7420) Mating With Molex:51110-1451 Terminal:0503948052 |
| Pin 11 | Remote Sense + |
| Pin 12 | Remote Sense - |
| Pin 13 | Current Share |