| Série | QAxx3(C)T-xxxxR3S-6W |
| Modèle | QA243CT-1505R3S-6W |
| Marque | MORNSUN |
| Tension de surtension (max. 1 s) | 12VDC Nominal input series: 20 VDC; 24VDC Nominal input series: 40 VDC; 12VDC Nominal input series: 30 VDC |
| Input no load current | 24VDC Nominal input series: 20mA; 12VDC Nominal input series: 40mA typ, 100mA max |
| Courant d’ondulation réfléchi | 24VDC Nominal input series: 50 typ, 100 max; 12VDC Nominal input series: 7.2 |
| Activation threshold | 24VDC Nominal input series: 17 VDC; 12VDC Nominal input series: 6.3 VDC |
| Shutdown threshold | 15 @24VDC Nominal input series |
| Filtre d’entrée | Capacitor filtering |
| Hot plug | Unavailable; Ctrl suspended or connected to TTL high; (2-12VDC) (Module on) |
| Ctrl | Module off: Ctrl to GND or to TTL low level (0-0.8VDC); Input current when off: 5mA typ, 10mA max |
| +Vo | 14.70–15.75 @Vin=12VDC, Pin3& Pin4 +Io= +300mA |
| -Vo | -4.65–-5.05 @Vin=12VDC, Pin3& Pin2 -Io= -300mA |
| Output -Vo | -9.60–-10.40 VDC @Vin=12VDC, Pin3& Pin1 -Io= -240mA |
| voltage +Vo | 14.70–15.60 @Vin=24VDC, Pin3& Pin4 +Io= +300mA |
| Précision de la tension de sortie | 10% -100% of load: %; (Figure 2-Figure typ, 13) max % |
| Régulation linéaire | % |
| Régulation de charge | % (1) (0% -100% Load) |
| Coefficient de température | ±0.04 %/℃ typ, ±0.1 %/℃ max (Full load) |
| Ondulation et bruit | 50mVp-p typ, 200mVp-p max (20MHz bandwidth) |
| Protection contre les courts-circuits | Continuous, self-recovery |
| Isolation (entrée–sortie) | VAC (, Test for 1 minute with a leakage) |
| Isolation | 5000 VAC |
| Continuous barrier withstand | 2000V (Input- output) |
| CMTI | ±200 kV/µs (Input- output) |
| Résistance d’isolement | Input-output resistance at 500VDC: 1000 MΩ |
| Isolation capacitor | Input- output, capacitor at 100kHz/0.1V: 13 pF typ, 15 pF max; Derating when operating temperature≥100℃,: pF |
| Température de fonctionnement | -40–105℃ ((see Fig. 1)) |
| Température de stockage | -55 to 125℃ |
| Dimensions | 39.98*27.81*: 7.60mm |
| Poids | 10.0g (Typ.) |
| Méthode de refroidissement | Natural air cold |
| Émissions CEM | CE: CISPR32/EN55032 CLASS A (see Table 2. for recommended circuit); |
| Immunité CEM | ESD: IEC/EN61000-4-2 Contact ±6kV perf. Criteria B |