| Série | PMR |
| Modèle | PMR-12V150W1AT |
| Type | Alimentations à découpage fermées |
| Marque | DELTA |
| Case Chassis | Aluminum |
| Case Cover | SGCC |
| Dimensions (L x W x H) | 129 x 97 x 30 mm (5.08 x 3.82 x 1.18 inch) |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Terminal | M3.5 x 7 Pins (Rated 300 V / 20 A) |
| Wire | AWG 18-12 Current rating can refer to page 6 “Wire AWG Table” Environment |
| Surrounding Air (Operating) | -40°C to +70°C |
| Temperature (Storage) | -40°C to +85°C |
| Power De-rating | > 50°C de-rate power by 2% / °C < 100Vac de-rate power by 1% / V (90% load @ 90 Vac) |
| Humidité de fonctionnement | 20 to 90% (Non-Condensing) |
| Operating Altitude | 0 to 5,000 Meters (0 to 16,400 ft) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz @ 2G;10Min per cycle,60min for X,Y,Z direction |
| Over Voltage Category | II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) Protections |
| Overvoltage (13.2 V - 16.8 V) | 26.4 V - 33.6 V 39.6 V - 48.6 V 52.8 V - 64.8 V |
| SELV Output, (SELV Output,) | SELV Output, SELV Output, |
| Latch Mode (Latch Mode) | Latch Mode Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Court-circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Protection Against Shock | Class I with PE*4 connection *4 PE: Protection Earth Reliability Data |
| MTBF | > 700,000 hrs as per Telcordia SR-332 (I/P: 230 Vac, O/P: 100% Load, Ta: 25°C) |
| Expected Cap Life Time | 10 years (230 Vac, 50% load @ 40°C) PMR Panel Mount Power Supply PMR 150 W series / PMR-□V150W1AT Safety Standards / Directives |
| Safety Entry Low Voltage | SELV |
| Electrical Safety (TUV Bauart) | EN 62368-1, EN 60335-1 |
| UL/cUL | UL 62368-1, and CAN/CSA C22.2 No. 62368-1 |
| CB scheme | IEC 62368-1, IEC 60335-1, IEC/EN 61558-1/-2-16 |
| EAC | TP TC 004/2011 |
| BSMI | CNS 15598-1 |
| CCC | GB 4943.1 |
| BIS | IS 13252(Part 1) |
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016 |
| Galvanic Isolation (Input to Output) | 4.0 KVac |
| Input to Ground | 2.0 KVac |
| Output to Ground | 1.25 KVac EMC*5 |
| Emissions | CISPR 32, EN/BS EN 55032, KS C 9832, AS/NZS CISPR32 & Compliance to FCC Title 47, |
| (CE & RE) | EN/BS EN 55014-1 , EN/BS 61000-6-3 , EN/BS EN 61000-6-4 : Class B |
| Immunity | EN/BS EN 55035, KS C 9835, & Compliance to EN/ BS EN 55014-2 , EN/BS EN 61000-6- 1 , EN/BS EN 61000-6-2 |
| Electrostatic (IEC 61000-4-2) | Level 4 Criteria A1) |
| Discharge | Air Discharge: 15 kV Contact Discharge: 8 kV |
| Radiated Field (IEC 61000-4-3) | Level 3 Criteria A1) 80 MHz – 1 GHz, 10 V/M, 80% Modulation (1 kHz) 1.4 GHz – 6 GHz, 3 V/M, 80% Modulation (1 kHz) |
| Electrical Fast (IEC 61000-4-4) | Level 3 Criteria A1) |
| Transient / Burst | 2 kV |
| Surge (IEC 61000-4-5) | Level 4 Criteria A1) Common Mode4): 4 kV Differential Mode5): 2 kV |
| Conducted (IEC 61000-4-6) | Level 3 Criteria A1) 150 kHz-80 MHz, 20 Vrms |
| Power Frequency (IEC 61000-4-8) | Level 4 Criteria A1) |
| Magnetic Fields | 30 A/Meter |
| Voltage Dips and (IEC 61000-4-11) | 0% residual; 1 cycle, Criteria B2) |
| Interruptions | 40% residual; 10 cycle, Criteria C3) 70% residual; 25 cycle, Criteria C3) |
| Harmonic Current | IEC/EN/BS EN 61000-3-2, Class A & Class D Emission |
| Voltage Fluctuation | IEC/EN/BS EN 61000-3-3 and Flicker |
| Voltage Sag Immunity (80% of 200 Vac) | 160 Vac, 1000 ms Criteria A1) |
| SEMI F47 – 0706 (70% of 200 Vac) | 140 Vac, 500 ms Criteria A1) |
| 50% of 200 Vac (100 Vac, 200 ms) | Criteria A1) 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test. 3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test) 4) Asymmetrical: Common mode (Line to earth) 5) Symmetrical: Differential mode (Line to line) |
| L | Vo+ |
| PFC Converter (DC/DC) | Output Rectifier |
| AC Input (EMI Filter) | & Inrush current limit Converter DC Output Filter & Filter |
| N | Vo- |