| Série | LOF600-20BxxR2 |
| Modèle | LOF600-20B48R2 |
| Marque | MORNSUN |
| Input Voltage Range (Rated) | 100–240 VAC |
| Plage de tension d’entrée (CA) | 80–264 |
| Plage de tension d’entrée (CC) | 110–370 VDC |
| Input Voltage Frequency | Hz; AC input: 47–63 Hz; Rated input (Certified voltage): 7.0 Hz |
| Courant d’entrée | 115VAC: 7.0A max; 230VAC: 3.5A max; 115VAC: 40A |
| Courant d’appel | 80A @230VAC (Cold start) |
| Facteur de puissance | 115VAC: 0.98; 230VAC: 0.95 |
| Input Fuse | 10A (Built-in fuse) |
| Branchement à chaud | Unavailable |
| Précision de la tension de sortie | ±3.0% (Full load range) |
| Régulation secteur | ±0.5% (Rated load) |
| Régulation de charge | ±1.0% (0% - 100% load) |
| Minimum Load | 0 (At room temperature, 230VAC input (when PS_ON is; at high potential)) |
| Stand-by Power Consumption | Vdd voltage: 3.3-15V, Vdd supply current: 0.5W; requirement: 5mA.When PS_ON is at a high level to: W; SGND, the power output is turned off: W; 24V: 200W (20MHz bandwidth) |
| Ondulation et bruit | mV; (peak-peak value) 48V: 250mV max |
| Coefficient de température | ±0.03%/℃; Air cooling (400W: %/℃; 12%/℃ |
| Temps de maintien | 230VAC, rated load, 25℃ Load): ms; 23CFM (600W Load): 8 ms |
| Protection contre les courts-circuits | Recovery time <3s after the short circuit disappear.: Hiccup, continuous, self-recover; ≥105% Io, hiccup, self-recover (Normal temperature,; high temperature) |
| Protection contre les surintensités | 100-240VAC, rated load: hiccup,; ≥105% full load after derating, hiccup,; Low temperature: hiccup,; self-recover hiccup,; 24V: ≤33.0VDC (Hiccup, self-recover) hiccup, |
| Protection contre les surtensions | 48V: ≤60.0VDC (Hiccup, self-recover); 65–90 %Vo (115VAC, Over-temperature; 100% load protection start) |
| Protection contre la surchauffe | ℃; 50–75; Offer output power of 12V/0.5A with (Recommended external Over-temperature; wind environment: 23CFM protection release) |
| Fan power | voltage accuracy ±15% (12V) |
| 2. *The “Tip and barrel method” is | and 0.1uF ceramic capacitor, please refer to AC-DC (used for ripple and noise test, output parallel 10uF electrolytic capacitor) |
| Isolation (entrée–sortie) | 4000 VAC |
| Isolation | 2000 VAC (Electric strength test for 1min., leakage current <5mA) |
| Isolation (Output–⏚) | 1500 VAC |
| Isolation (Input–⏚) | 100 VAC |
| Résistance d’isolement | Input - output Relative humidity: < 95%RH, no condensation: 100 MΩ; Test voltage: 500VDC: MΩ; Output -: 100 MΩ |
| Température de fonctionnement | -40 to 85℃ |
| Température de stockage | -40–85℃ |
| Humidité de stockage | 10–95 %RH; No condensation: %RH |
| Humidité de fonctionnement | 20–90 %RH |
| Power Derating | Operating 23CFM -40℃ - +50℃: 0 %/℃; 2.5; +70℃ - +85℃: 1.33; -40℃ - +40℃: 0; Air 230VAC +40℃ - +60℃: 1.1; cooling +60℃ - +70℃: 1.5; -40℃ - +30℃: 0; 250W 115VAC +30℃ - +60℃: 1; +60℃ - +70℃: 0.9; Input voltage 80VAC-115VAC: 1.14 %/VAC; derating 115VAC-264VAC: 0; Touch current: <0.1mA (temperature rated power 600W +50℃ - +70℃; derating; rated; power) |
| Courant de fuite | Earth leakage current: <0.5mA max; BS EN62368-1, EN62368-1(Report); Design refer to IEC/UL62368-1, (240VAC, 60Hz) |
| Safety Standard | GB4943.1; –IEC/EN61558-1; IEC/EN/ES60601-1; CLASS I (with PE and must be connected)/ |
| Classe de sécurité | CLASS II (without PE) |
| MTBF | ≥200,000 h (MIL-HDBK-217F@25℃) |
| Warranty | 3 years (Ambient temperature: <25℃) |
| Item | Operating Conditions: Min.–Max. Unit; Vdd voltage: 3.3–15 Unit |
| PS_ON Input Signal | Power on PS_ON low: 0–0.6 V; Power off PS_ON high: 3.3–24 V; High level High: 2–5 V; Low level Low: 0–1 V; The PG signal goes high: V |
| PG Signal | Power on with 10ms to 500ms delay: 10–500 ms; after power set up: ms; The TTL signal goes low at: ms; Power off/Power: ms; least 1ms before output: 1 ms; fail: ms; below 90% of rated value: ms; The total compensation voltage value when Vs+ and: ms; Vs- (pins S1 and S2 of CN2) are respectively: ms |
| Remote Sense | 0.5mV; short-circuited to the output load terminals (RS+: mV; short-circuited to +Vo, RS- short-circuited to -VO): mV; Main output status Normal output: Green on mV |
| LED Signal | indication Power off (AC without Input): Light off; When RS+ and RS- are connected to the system, |
| High and Low Temperature | GB2423.1, typ, IEC60068-2-1 max (Working +85℃, -40℃) |
| Sinusoidal Vibration | GB2423.10, typ, IEC60068-2-6 max (10 - 500Hz, 2g, three directions of X, Y, Z axis) |
| Low Temperature Storage | GB2423.1, typ, IEC60068-2-1 max (-40℃) |
| High Temperature Storage | GB2423.2, typ, IEC60068-2-2 max (+85℃) |
| High Temperature Aging | GB2423.2, typ, IEC60068-2-2 max (+50℃) |
| Normal Temperature Aging | GB2423.1, typ, IEC60068-2-1 max (+25℃) |
| Temperature Shock | GB2423.22, typ, IEC60068-2-14 max (-40℃ to +85℃) |
| Temperature Cycle | GB2423.22, typ, IEC60068-2-14 max (-25℃ to +60℃) |
| Hot and Humid | GB2423.50, typ, IEC60068-2-67 max (+85℃, 85%RH) |
| High Temperature Elevation | GB2423.26, typ, IEC60068-2-41 max (+60℃, 54KPa) |
| Low Temperature Elevation | GB2423.25, typ, IEC60068-2-40 max (-25℃, 54KPa) |
| Constant Humid and Hot | GB2423.3, typ, IEC60068-2-78 max (+40℃, 95%RH) |
| Sinusoidal Vibration Response | GB/T typ, 11287-2000, max IEC60255-21-1 (10 - 150Hz, 1g, three directions of X, Y, Z axis) |
| Sinusoidal Impulse Response | 15g, pulse duration 11ms, three times in each: direction of X, IEC60255-21-2; GB/T typ, 114537-1993, max IEC60255-21-2 |
| Packaging Drop | GB2423.8, typ, IEC68-2-32 max (1m, one corner, three edges and six sides) |
| Matériau du boîtier | Open frame |
| Dimension | 127.00mm × 76.20mm × 33.50mm |
| Poids | 490g (Typ.) |
| Cooling Method* | Air cooling (400W) / 23CFM (600W) |
| Émissions CEM | CE: CISPR32/EN55032 (CLASS I CLASS B, CLASS II CLASS A) |
| Immunité CEM | Harmonic current: IEC/EN61000-3-2 CLASS A and CLASS D; ESD: IEC/EN 61000-4-2 Contact ±8KV/Air ±15KV (perf. Criteria A); RS: IEC/EN 61000-4-3 10V/m (perf. Criteria A); EFT: IEC/EN 61000-4-4 ±2KV (perf. Criteria A); Surge: IEC/EN 61000-4-5 ±2KV/±4KV (perf. Criteria A); CS: IEC/EN61000-4-6 10 Vr.m.s (perf. Criteria A); Voltage drop: 40% 240 ,10/12 periods (50/60Hz) (perf. Criteria B); Voltage interruption: 0% 240 ,250/300 periods (50/60Hz) (perf. Criteria C) |