Descripción del producto: La serie ADT de DELTA (Cargadores y adaptadores). Modelos de esta serie: ADT-060A12AA / ADT-060A12AB / ADT-060A15AA / ADT-060A15AB / ADT-060A19AA / ADT-060A19AB / ADT-060A24AA / ADT-060A24AB / ADT-090A24AA / ADT-120A19AA / ADT-120A24AA / ADT-150A19AA / ADT-150A24AA / ADT-150A24AA H-A / ADT-150A24AA K-A / ADT-150B12AA / ADT-150C24AC. Consulte la hoja de datos del fabricante a continuación para conocer las especificaciones completas y la información de pedido.

Aspectos destacados: Modelos de esta serie: ADT-060A12AA / ADT-060A12AB / ADT-060A15AA / ADT-060A15AB / ADT-060A19AA / ADT-060A19AB / ADT-060A24AA / ADT-060A24AB / ADT-090A24AA / ADT-120A19AA / ADT-120A24AA / ADT-150A19AA / ADT-150A24AA / ADT-150A24AA H-A / ADT-150A24AA K-A / ADT-150B12AA / ADT-150C24AC

Precio: Precio bajo consulta

Consultar ahora +

Desplácese hacia abajo para más detalles

Correo electrónico: changtaowu6@gmail.com
WhatsApp: +84 346 271 021 · WeChat: 13058353823
Teléfono: +86 130 5835 3823

Introducción del producto Casos de cooperación Más productos
INTRODUCCIÓN DEL PRODUCTO

Introducción del producto

Descripción del producto

La serie ADT de DELTA (Cargadores y adaptadores). Modelos de esta serie: ADT-060A12AA / ADT-060A12AB / ADT-060A15AA / ADT-060A15AB / ADT-060A19AA / ADT-060A19AB / ADT-060A24AA / ADT-060A24AB / ADT-090A24AA / ADT-120A19AA / ADT-120A24AA / ADT-150A19AA / ADT-150A24AA / ADT-150A24AA H-A / ADT-150A24AA K-A / ADT-150B12AA / ADT-150C24AC. Consulte la hoja de datos del fabricante a continuación para conocer las especificaciones completas y la información de pedido.

Aspectos destacados

Modelos de esta serie: ADT-060A12AA / ADT-060A12AB / ADT-060A15AA / ADT-060A15AB / ADT-060A19AA / ADT-060A19AB / ADT-060A24AA / ADT-060A24AB / ADT-090A24AA / ADT-120A19AA / ADT-120A24AA / ADT-150A19AA / ADT-150A24AA / ADT-150A24AA H-A / ADT-150A24AA K-A / ADT-150B12AA / ADT-150C24AC

Guía de selección

ModeloPotencia de salidaTensión / Corriente de salidaRango ajustableEficienciaCarga capacitiva máxima
ADT-060A12AA60W12V
ADT-060A12AB60W12V
ADT-060A15AA60W15V
ADT-060A15AB60W15V
ADT-060A19AA60W19V
ADT-060A19AB60W19V
ADT-060A24AA60W24V
ADT-060A24AB60W24V
ADT-090A24AA90W24V
ADT-120A19AA120W19V
ADT-120A24AA120W24V
ADT-150A19AA150W19V
ADT-150A24AA150W24V
ADT-150A24AA H-A150W24V
ADT-150A24AA K-A150W24V
ADT-150B12AA
ADT-150C24AC

Note: voltage/power not parseable from model name: ADT-150B12AA, ADT-150C24AC

Documentación del fabricante

Desplácese hacia abajo para más detalles

ADT Series datasheet page 1 ADT Series datasheet page 2 ADT Series datasheet page 3 ADT Series datasheet page 4 ADT Series datasheet page 5 ADT Series datasheet page 6 ADT Series datasheet page 7 ADT Series datasheet page 8

Especificaciones

SerieADT
ModeloADT-060A12AA
TipoCargadores y adaptadores
MarcaDELTA
Nominal Output Voltage (12 Vdc)15 Vdc 19 Vdc 24 Vdc
Rated Output Current (5A)4A 3.2A 2.5 A
Output Power (60 W)60 W 60.8 W 60 W
Regulación de línea± 1%
Load Regulation (± 5.0%)± 4.0% ± 3.0% ± 2.5%
Combine Regulation (± 8.0%)± 7.0% ± 5.0% ± 5.0%
PARD* (20MHz) (0°C to 40°C)< 240 mVpp < 300 mVpp < 380 mVpp < 480 mVpp
-10°C to 0°C (< 480 mVpp)< 600 mVpp < 760 mVpp < 960 mVpp
Rise Time (115 Vac)30 mS (typ.) 230 Vac
Start-up Time (115 Vac)1000 ms (typ.)
230 Vac500 ms (typ.)
Hold-up Time (115 Vac)12 ms (typ.)
Capacitive load (max)470 uF *PARD is measured with an AC coupling mode, and in parallel with 0.1µF ceramic capacitor & 22µF electrolytic capacitor. Mechanical
CasePC
Dimensions (W x L x H)46.0 x 108.0 x 29.5 mm (1.81 x 4.25 x 1.16 inch)
Cooling SystemConvection
Output Cable (Length: 1200 mm)#16AWG ADT-060A12AA B / ADT-060A12AB B
SpecificationUL1571
#18AWGADT-060A15AA B / ADT-060A15AB B
#20AWGADT-060A19AA B / ADT-060A19AB B ADT-060A24AA B / ADT-060A24AB B
Input Socket (C6)ADT-060A12AA B ADT-060A15AA B ADT-060A19AA B ADT-060A24AA B
C8ADT-060A12AB B ADT-060A15AB B ADT-060A19AB B ADT-060A24AB B TECHINCAL DATASHEET AC-DC Adapter Environment
Surrounding Air (Operating)-10°C to +60°C
Temperature(-20°C cold start @ 100% Load)
Storage-40°C to +85°C
Power De-rating> 40°C de-rating power by 2.5% / °C < 90Vac de-rating power by 2% / V
Humedad de funcionamiento5 to 95% RH (Non-Condensing)
Humedad de almacenamiento5 to 95% RH (Non-Condensing)
Operating AltitudeUp to 5,000 meters (up to 16,400 feet)
Ball Impact TestTest height 130 cm, 1 sample 1 time, Steel Ball 500 g, Concrete floor Test height 100 cm, 6 face for each sample, concrete floor
Drop TestFunction test pass after drop test
Shock Test (Non-Operating)Half sine wave, 50 G, 11 ms, 1 shocks for each direction, 6 direction
Vibration (Non-Operating)5-500 Hz, 2.09 Grms, 20 minute for X,Y,Z axis Protections
Overvoltage (13.2-18.0 V,)16.5-22.5 V, 20.9-28.5 V, 26.4-36.0 V,
Latch Mode (Latch Mode)Latch Mode Latch Mode
5.25-10.00 A (4.20-8.00 A)3.36-6.40 A 2.625-5.00 A Overload / Overcurrent Auto-Recovery when the fault is removed
Over TemperatureLatch Mode
CortocircuitoAuto-Recovery when the fault is removed
Protection Against ShockADT-060A12AA B ADT-060A15AA B ADT-060A19AA B ADT-060A24AA B Class II ADT-060A12AB B ADT-060A15AB B ADT-060A19AB B ADT-060A24AB B Reliability Data
MTBF> 700,000 hrs. per Telcordia SR-332 at Input: 115 Vac, Output: 100% load, Ta: 25°C
Expected Cap Life Time5 years (50% load @ 25°C) TECHINCAL DATASHEET AC-DC Adapter Safety Standards / Directives
Electrical Safety (CB scheme)IEC/UL/EN 60950-1; IEC/UL/EN 62368-1
BSMICNS 14336-1
CCCGB 4943.1-2011
PSEJ 60950-1(H29)
KCK 60950-1
Limited Power Source (CB scheme)IEC 62368-1 (LPS)
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
UKCAIn conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
Galvanic Isolation (Input to Output)3000 Vac EMC
Emissions (CE & RE)CISPR/EN/BS EN 55032 Class B BSMI CNS 13438 FCC Part 15, ICES-003, ANSI C63.4 GB/T9254- 2008 KN32
ImmunityEN/BS EN 55024; KN35
Radiated andConducted Emissions: EN/BS EN 55032 Class B
Conducted EmissionsRadiated Emissions: EN/BS EN 55032 Class B
Flicker and VoltageIEC 61000-3-3 Fluctuation
Harmonic Current (IEC 61000-3-2)Class D; GB 17625.1-2003 Emissions
Electrostatic (IEC 61000-4-2)Criteria A1)
Discharge StandardAir Discharge: 15 kV Contact Discharge: 8 kV
Radiated Field (IEC 61000-4-3)Level 2 Criteria A1)
Immunity Test80 MHz – 1 GHz, 3 V/M with 1 kHz tone / 80% modulation.

Envíe el número de modelo completo, la cantidad, el voltaje de entrada y los detalles de la aplicación. Confirmaremos disponibilidad y cotización.

Comparación de series

SerieTipoPotencia de salidaTensión de salidaModelo
ADPCargadores y adaptadores——ADP-100XB BD
ADTCargadores y adaptadores——ADT-060A12AA

Por qué elegirnos

  • Productos originales

    Todos los productos son originales e incluyen documentación del fabricante y soporte de fábrica.

  • Compra directa por modelo

    Sin conjeturas: ingenieros y compradores se comunican con el número de modelo exacto.

  • Cotización de costo en destino

    Las cotizaciones incluyen precio, stock, compatibilidad y envío de exportación: el costo completo, sin sorpresas.

  • Exportación global

    Atendemos a ingenieros, compradores e integradores en el extranjero con envíos a varios países.

  • Soporte multicanal

    Correo, WhatsApp, teléfono y WeChat: respuestas rápidas.

  • Compra integral

    Fuentes de alimentación, accionamientos, sensores y componentes de baja tensión en un solo lugar.

Casos de cooperación

Más casos →

Más productos

Ver todos los productos →

SU SOLICITUD DE ABASTECIMIENTO

Lista de consulta

CorreoDestino

El correo abre su aplicación de correo. WhatsApp abre un mensaje preparado. Revise y envíe su consulta allí; no se envía automáticamente.

Products
body>