| السلسلة | AH500 |
| الطراز | AH500 |
| النوع | PLC والتحكم في الحركة |
| العلامة التجارية | DELTA |
| input/output | AH04AD-5A, AH08AD-5A , AH08AD-5B, AH08AD-5C, AH04DA-5A, |
| module | AH08DA-5A, AH08DA-5B, AH08DA-5C, and AH06XA-5A Temperature Measuring the temperature measurement AH04PT-5A, AH08PTG-5A, AH04TC-5A, and AH08TC-5A module |
| control | AH02HC-5A, AH04HC-5A, AH05PM-5A, AH10PM-5A, AH15PM-5A, and |
| Network | network modules can be installed on the main backplane except AH10SCM-5A.) |
| (4) | Larger program capacity and memory The AH500 series basic CPU modules (AHCPU500/510/520/530) have 32/64/128/256K steps, and 16/32/64K words of memory. Besides, users can declare up to 64/256/512/1024 function blocks. The AH500 series advanced CPU modules (AHCPU511/521/531) have 96/192/384K steps, and 48/96/128K words of memory. Besides, users can declare up to 1024/2048/4096 function blocks. Provided with various CPU modules for users to choose from to satisfy the different programming |
| (5) | Supporting IEC 61131-3 The AH500 series CPU module supports IEC 61131-3. The programming languages which are supported are instruction lists (IL), structured texts (ST), ladder diagrams (LD), sequential function charts (SFC), and function block diagrams (FBD). 1-9 AH500 Hardware Manual Users can select a programming language according to their preference and the convenience. The programming languages support one another so that the programs written by different users are |
| (6) | Strong function block Not only the standard IEC61131-3 function blocks are supported, but also the convenient function blocks provided by Delta Electronics, Inc. are supported. Users can write the program frequently executed in a function block so that the program becomes more structured and can be executed more conveniently. The symbol for a function block in a ladder diagram is like an Integrated circuit (IC) in a circuit diagram. |
| (7) | Task The programs can be assigned to 283 tasks at most. Among the 288 tasks, 32 tasks are cyclic tasks, 32 tasks are I/O interrupts, 4 tasks are timer interrupts, 2 tasks are communication interrupts, 1 task is an external 24 V low-voltage interrupt, and 212 tasks are user-defined tasks. Users can enable and disable a task during the execution of a program by means of TKON and TKOFF. |
| (8) | Increasing the efficiency of configuring the hardware through an USB cable and ISPSoft The AH500 series CPU module provides a standard USB 2.0 interface. USB 2.0 increases the data transfer rate, and decreases the time it takes to download the program, monitor the program and configure the hardware. Besides, users do not need to buy a communication cable for the CPU module. They can use a general USB cable to connect to the AH500 series CPU module. |
| CPU530 -RS2 | C PU5 3 0-EN |
| COM1 | COM COM2 Ether net C O M |
| USB | USB COM C O M AHCPU500/510/520/530-RS2 provides two DB9 serial control interfaces, i.e. COM1 and COM2. AHCPU500/510/520/530-EN provides one DB9 serial control interface, i.e. COM. Users can set the DB9 serial control interface to RS232, RS485, or RS422 according to the application environment. The data transfer rate can be increased from 9600 bps to 1 Mbps. 1 - 11 AH500 Hardware Manual For the AH500 series basic CPU modules (AHCPU500/510/520/530), after users set the PLC Link |
| monitoring function, they have to click | . The debugging screen varies from programming 1-12 C h a p t e r 1 I n t r o d u c t i o n o f P r o d u c ts language to programming language, but the same operation applies to these programming languages. For the AH500 series PLC, structured texts do not support the debugging mode, and sequential function charts support the debugging mode during the action and the transition. Step 1: Setting the PLC to RUN |
| POWER (CPU) | I/O0 I/O1 I/O2 I/O3 I/O4 I/O5 I/O6 I/O7 2-2 C h a p t e r 2 I n s ta l l i n g H a r d wa r e A power supply module functions to convert alternating current to direct current, or directly provides direct current. It provides power for the modules installed on it. A backplane must be assigned a power supply module whether it is a main backplane or an extension backplane. A power supply module has to be |
| Communication port | DB9 (RS-232/422/485) Computer/HMI communication/Remote control/Data |
| Ethernet | RJ45 exchange/Industrial control network |
| DeviceNet | DeviceNet The maximum data transmission rate is 1 Mbps. |
| Interface on an | Delta Extension cable for a complete AH500 system |
| AH16AR10N-5A | 16 inputs Terminal block (I/O interrupts are supported.) 2-4 |