Automatisation industrielle. Connectée à votre prochain projet.Guangzhou Hongwei · Fondée en 2021
changtaowu6@gmail.com ↗13058353823
Accueil / Produits / DELTA / PMR Series
PMR Series

PMR Series

Date de publication: 2026-11-15

Description du produit: La série PMR de DELTA (Alimentations à découpage fermées). Modèles de cette série: PMR-12V150W1AT / PMR-12V1K0W1BT / PMR-12V240W1AT / PMR-12V320W1AT / PMR-12V600W1BT / PMR-24V150W1AT / PMR-24V1K0W1BT / PMR-24V1K5W1BTB / PMR-24V240W1AJ / PMR-24V240W1AT / PMR-24V320W1AT / PMR-24V600W1BT / PMR-36V150W1AT / PMR-36V1K0W1BT / PMR-36V240W1AT / PMR-36V320W1AT / PMR-36V600W1BT / PMR-48V150W1AT / PMR-48V1K0W1BT / PMR-48V1K5W1BTC / PMR-48V240W1AT / PMR-48V320W1AT / PMR-48V600W1BT / PMR-4V320WCAA / PMR-4V320WCGA / PMR-4V320WDAA / PMR-4V320WDBA / PMR-4V320WDCA / PMR-4V320WDGA / PMR-5V320WCAA / PMR-5V320WCGA / PMR-5V320WDAA / PMR-5V320WDBA / PMR-5V320WDCA / PMR-5V320WDGA. Veuillez consulter la fiche technique du fabricant ci-dessous pour connaître les spécifications complètes et les informations de commande.

Points forts: Modèles de cette série: PMR-12V150W1AT / PMR-12V1K0W1BT / PMR-12V240W1AT / PMR-12V320W1AT / PMR-12V600W1BT / PMR-24V150W1AT / PMR-24V1K0W1BT / PMR-24V1K5W1BTB / PMR-24V240W1AJ / PMR-24V240W1AT / PMR-24V320W1AT / PMR-24V600W1BT / PMR-36V150W1AT / PMR-36V1K0W1BT / PMR-36V240W1AT / PMR-36V320W1AT / PMR-36V600W1BT / PMR-48V150W1AT / PMR-48V1K0W1BT / PMR-48V1K5W1BTC / PMR-48V240W1AT / PMR-48V320W1AT / PMR-48V600W1BT / PMR-4V320WCAA / PMR-4V320WCGA / PMR-4V320WDAA / PMR-4V320WDBA / PMR-4V320WDCA / PMR-4V320WDGA / PMR-5V320WCAA / PMR-5V320WCGA / PMR-5V320WDAA / PMR-5V320WDBA / PMR-5V320WDCA / PMR-5V320WDGA

Prix: Prix sur demande

Demander maintenant +

Faites défiler pour plus de détails

E-mail : changtaowu6@gmail.com
WhatsApp : +84 346 271 021 · WeChat : 13058353823
Téléphone : +86 130 5835 3823

Présentation du produit Cas d'application Plus de produits
PRÉSENTATION DU PRODUIT

Présentation du produit

Description du produit

La série PMR de DELTA (Alimentations à découpage fermées). Modèles de cette série: PMR-12V150W1AT / PMR-12V1K0W1BT / PMR-12V240W1AT / PMR-12V320W1AT / PMR-12V600W1BT / PMR-24V150W1AT / PMR-24V1K0W1BT / PMR-24V1K5W1BTB / PMR-24V240W1AJ / PMR-24V240W1AT / PMR-24V320W1AT / PMR-24V600W1BT / PMR-36V150W1AT / PMR-36V1K0W1BT / PMR-36V240W1AT / PMR-36V320W1AT / PMR-36V600W1BT / PMR-48V150W1AT / PMR-48V1K0W1BT / PMR-48V1K5W1BTC / PMR-48V240W1AT / PMR-48V320W1AT / PMR-48V600W1BT / PMR-4V320WCAA / PMR-4V320WCGA / PMR-4V320WDAA / PMR-4V320WDBA / PMR-4V320WDCA / PMR-4V320WDGA / PMR-5V320WCAA / PMR-5V320WCGA / PMR-5V320WDAA / PMR-5V320WDBA / PMR-5V320WDCA / PMR-5V320WDGA. Veuillez consulter la fiche technique du fabricant ci-dessous pour connaître les spécifications complètes et les informations de commande.

Points forts

Modèles de cette série: PMR-12V150W1AT / PMR-12V1K0W1BT / PMR-12V240W1AT / PMR-12V320W1AT / PMR-12V600W1BT / PMR-24V150W1AT / PMR-24V1K0W1BT / PMR-24V1K5W1BTB / PMR-24V240W1AJ / PMR-24V240W1AT / PMR-24V320W1AT / PMR-24V600W1BT / PMR-36V150W1AT / PMR-36V1K0W1BT / PMR-36V240W1AT / PMR-36V320W1AT / PMR-36V600W1BT / PMR-48V150W1AT / PMR-48V1K0W1BT / PMR-48V1K5W1BTC / PMR-48V240W1AT / PMR-48V320W1AT / PMR-48V600W1BT / PMR-4V320WCAA / PMR-4V320WCGA / PMR-4V320WDAA / PMR-4V320WDBA / PMR-4V320WDCA / PMR-4V320WDGA / PMR-5V320WCAA / PMR-5V320WCGA / PMR-5V320WDAA / PMR-5V320WDBA / PMR-5V320WDCA / PMR-5V320WDGA

Guide de sélection

ModèlePuissance de sortieTension / Courant de sortiePlage de réglageRendementCharge capacitive max.
PMR-12V150W1AT150W12V / 12.5 A
PMR-12V1K0W1BT1000W12V
PMR-12V240W1AT240W12V
PMR-12V320W1AT320W12V
PMR-12V600W1BT600W12V
PMR-24V150W1AT150W24V
PMR-24V1K0W1BT1000W24V
PMR-24V1K5W1BTB1500W24V
PMR-24V240W1AJ240W24V
PMR-24V240W1AT240W24V
PMR-24V320W1AT320W24V
PMR-24V600W1BT600W24V
PMR-36V150W1AT150W36V
PMR-36V1K0W1BT1000W36V
PMR-36V240W1AT240W36V
PMR-36V320W1AT320W36V
PMR-36V600W1BT600W36V
PMR-48V150W1AT150W48V
PMR-48V1K0W1BT1000W48V
PMR-48V1K5W1BTC1500W48V
PMR-48V240W1AT240W48V
PMR-48V320W1AT320W48V
PMR-48V600W1BT600W48V
PMR-4V320WCAA320W4V
PMR-4V320WCGA320W4V
PMR-4V320WDAA320W4V
PMR-4V320WDBA320W4V
PMR-4V320WDCA320W4V
PMR-4V320WDGA320W4V
PMR-5V320WCAA320W5V
PMR-5V320WCGA320W5V
PMR-5V320WDAA320W5V
PMR-5V320WDBA320W5V
PMR-5V320WDCA320W5V
PMR-5V320WDGA320W5V

Documentation du fabricant

Faites défiler pour plus de détails

PMR Series datasheet page 1 PMR Series datasheet page 2 PMR Series datasheet page 3 PMR Series datasheet page 4 PMR Series datasheet page 5 PMR Series datasheet page 6 PMR Series datasheet page 7 PMR Series datasheet page 8 PMR Series datasheet page 9 PMR Series datasheet page 10 PMR Series datasheet page 11

Caractéristiques

SériePMR
ModèlePMR-12V150W1AT
TypeAlimentations à découpage fermées
MarqueDELTA
Case ChassisAluminum
Case CoverSGCC
Dimensions (L x W x H)129 x 97 x 30 mm (5.08 x 3.82 x 1.18 inch)
IndicatorGreen LED (DC OK)
Cooling SystemConvection
TerminalM3.5 x 7 Pins (Rated 300 V / 20 A)
WireAWG 18-12 Current rating can refer to page 6 “Wire AWG Table” Environment
Surrounding Air (Operating)-40°C to +70°C
Temperature (Storage)-40°C to +85°C
Power De-rating> 50°C de-rate power by 2% / °C < 100Vac de-rate power by 1% / V (90% load @ 90 Vac)
Humidité de fonctionnement20 to 90% (Non-Condensing)
Operating Altitude0 to 5,000 Meters (0 to 16,400 ft)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction
Vibration (Operating)IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz @ 2G;10Min per cycle,60min for X,Y,Z direction
Over Voltage CategoryII (Compliance to EN 62477-1 OVC III with 2000 meters altitude) Protections
Overvoltage (13.2 V - 16.8 V)26.4 V - 33.6 V 39.6 V - 48.6 V 52.8 V - 64.8 V
SELV Output, (SELV Output,)SELV Output, SELV Output,
Latch Mode (Latch Mode)Latch Mode Latch Mode
Overload / Overcurrent110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
Over TemperatureLatch Mode
Court-circuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Protection Against ShockClass I with PE*4 connection *4 PE: Protection Earth Reliability Data
MTBF> 700,000 hrs as per Telcordia SR-332 (I/P: 230 Vac, O/P: 100% Load, Ta: 25°C)
Expected Cap Life Time10 years (230 Vac, 50% load @ 40°C) PMR Panel Mount Power Supply PMR 150 W series / PMR-□V150W1AT Safety Standards / Directives
Safety Entry Low VoltageSELV
Electrical Safety (TUV Bauart)EN 62368-1, EN 60335-1
UL/cULUL 62368-1, and CAN/CSA C22.2 No. 62368-1
CB schemeIEC 62368-1, IEC 60335-1, IEC/EN 61558-1/-2-16
EACTP TC 004/2011
BSMICNS 15598-1
CCCGB 4943.1
BISIS 13252(Part 1)
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
UKCAIn conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
Galvanic Isolation (Input to Output)4.0 KVac
Input to Ground2.0 KVac
Output to Ground1.25 KVac EMC*5
EmissionsCISPR 32, EN/BS EN 55032, KS C 9832, AS/NZS CISPR32 & Compliance to FCC Title 47,
(CE & RE)EN/BS EN 55014-1 , EN/BS 61000-6-3 , EN/BS EN 61000-6-4 : Class B
ImmunityEN/BS EN 55035, KS C 9835, & Compliance to EN/ BS EN 55014-2 , EN/BS EN 61000-6- 1 , EN/BS EN 61000-6-2
Electrostatic (IEC 61000-4-2)Level 4 Criteria A1)
DischargeAir Discharge: 15 kV Contact Discharge: 8 kV
Radiated Field (IEC 61000-4-3)Level 3 Criteria A1) 80 MHz – 1 GHz, 10 V/M, 80% Modulation (1 kHz) 1.4 GHz – 6 GHz, 3 V/M, 80% Modulation (1 kHz)
Electrical Fast (IEC 61000-4-4)Level 3 Criteria A1)
Transient / Burst2 kV
Surge (IEC 61000-4-5)Level 4 Criteria A1) Common Mode4): 4 kV Differential Mode5): 2 kV
Conducted (IEC 61000-4-6)Level 3 Criteria A1) 150 kHz-80 MHz, 20 Vrms
Power Frequency (IEC 61000-4-8)Level 4 Criteria A1)
Magnetic Fields30 A/Meter
Voltage Dips and (IEC 61000-4-11)0% residual; 1 cycle, Criteria B2)
Interruptions40% residual; 10 cycle, Criteria C3) 70% residual; 25 cycle, Criteria C3)
Harmonic CurrentIEC/EN/BS EN 61000-3-2, Class A & Class D Emission
Voltage FluctuationIEC/EN/BS EN 61000-3-3 and Flicker
Voltage Sag Immunity (80% of 200 Vac)160 Vac, 1000 ms Criteria A1)
SEMI F47 – 0706 (70% of 200 Vac)140 Vac, 500 ms Criteria A1)
50% of 200 Vac (100 Vac, 200 ms)Criteria A1) 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test. 3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test) 4) Asymmetrical: Common mode (Line to earth) 5) Symmetrical: Differential mode (Line to line)
LVo+
PFC Converter (DC/DC)Output Rectifier
AC Input (EMI Filter)& Inrush current limit Converter DC Output Filter & Filter
NVo-

Envoyez le numéro de modèle complet, la quantité, la tension d'entrée et les détails de l'application. Nous confirmerons la disponibilité et le devis.

Comparaison des séries

SérieTypePuissance de sortieTension de sortieModèle
IMASortie unique——IMA-S1000-12
mPSUSortie unique——mPSU-W1AC-24DC-1000
PMCSortie unique——PMC-05V015W1AA
PMFSortie unique——PMF-24V240WCGB
PMHSortie unique——PMH-12V100WCLS
PMRSortie unique——PMR-12V150W1AT
PMSSortie unique——PMS-12V2K5W1BTD
PMTSortie unique——PMT-12V100W1AA
PMT2 ECO (High Line)Sortie unique——PMT-24V100W2BNJ
PMT2Sortie unique——PMT-12V100W2BA
PMUSortie unique——PMU-13V155WCBA

Pourquoi nous choisir

  • Produits authentiques

    Tous les produits sont d'origine et fournis avec la documentation du fabricant et l'assistance de l'usine.

  • Approvisionnement direct par référence

    Aucune approximation : ingénieurs et acheteurs communiquent avec la référence exacte du modèle.

  • Devis au coût rendu

    Les devis incluent prix, stock, compatibilité et expédition export : le coût complet, sans surprise.

  • Exportation mondiale

    Nous servons les ingénieurs, acheteurs et intégrateurs à l'étranger avec une expédition vers plusieurs pays.

  • Assistance multicanale

    E-mail, WhatsApp, téléphone et WeChat : réponses rapides.

  • Approvisionnement tout-en-un

    Alimentations, variateurs, capteurs et composants basse tension au même endroit.

Cas d'application

Plus de cas →

Plus de produits

Voir tous les produits →

VOTRE DEMANDE D’APPROVISIONNEMENT

Liste de demande de devis

E-mailDestination

L’e-mail ouvre votre application de messagerie. WhatsApp ouvre un message préparé. Vérifiez et envoyez votre demande là-bas ; elle n’est pas envoyée automatiquement.

Produits
body>