| Série | PMH |
| Modèle | PMH-12V100WCLS |
| Type | Alimentations à découpage fermées |
| Marque | DELTA |
| Case Chassis / Cover | Aluminium |
| Dimensions (L x W x H) | 129 x 97 x 30 mm (5.08 x 3.82 x 1.18 inch) |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Terminal (PMH-12V100WCLS) | M3.5 x 7 Pins (Rated 300V/15A) |
| Input: B3P(6-2.3.5)-VH(LF)(SN) | Input: VHR-6N |
| Output: B4P7-VH(LF)(SN) | Output: VHR-7N |
| Wire (PMH-12V100WCLS) | AWG 20-14 |
| Noise (1 Meter from power supply) | Sound Pressure Level (SPL) < 25dBA Environment |
| Surrounding Air Temperature (Operating) | -30°C to +70°C |
| Storage | -40°C to +85°C |
| Power De-rating (Temperature) | 120Vac < -25°C de-rate power by 5.0% / °C 120Vac and 240Vac > 50°C de-rate power by 2.0% / °C |
| Tension d’entrée | < 100Vac de-rate power by 1.33%/°C |
| Humidité de fonctionnement | 5 to 95% RH (Non-Condensing) |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft.) |
| Shock Test (Non-Operating) | IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms,3 times per direction, 9 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); displacement of 0.35mm; 20 min per axis for all X, Y, Z direction |
| Bump (Non-Operating) | IEC 60068-2-29, 10G (100m/S²) for a duration of 11ms,1000 times per direction, 6000 times in total |
| Over Voltage Category | II PMH Panel Mount Power Supply 12V 100W 1 Phase / PMH-12V100WCL□ Protections |
| Overvoltage | < 17.5V, SELV Output, Latch mode |
| Overload / Overcurrent | 115~150% of rated load current, Hiccup mode, Non-Latching (Auto-Recovery) |
| Over Temperature | < 75°C Surrounding Air Temperature @ 100% load, Latch mode |
| Court-circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Internal Fuse at L pin | T 3.15AH |
| Degree of Protection | IP20 (PMH-12V100WCLU) |
| Protection Against Shock | Class I with PE* connection *PE: Primary Earth Reliability Data |
| MTBF | > 700,000 hrs. as per Telcordia SR-332 I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C |
| Expected Cap Life Time | 10 years (115Vac & 230Vac, 50% load @ 40°C) Safety Standards / Directives |
| Safety Entry Low Voltage | SELV (EN 60950-1) |
| Electrical Safety (SIQ Bauart) | EN 60950-1, EN 60335-1, EN 61558-1, EN 61558-2-16, EN 62368-1 |
| UL/cUL recognized | UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) |
| CB scheme | IEC 60950-1, IEC 60335-1, IEC 61558-1, IEC 61558-2-16, IEC 62368-1 |
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation (Input to Output) | 4.0KVac |
| Input to Ground | 2.0KVac |
| Output to Ground | 1.0KVdc PMH Panel Mount Power Supply 12V 100W 1 Phase / PMH-12V100WCL□ EMC |
| Emissions (CE & RE) | EN 55011, EN 55032, CISPR 32, FCC Title 47: Class B, EN 61000-6-3 |
| Component Power Supply for General Use | EN 61204-3 |
| Immunity | EN 55024, EN 61000-6-2 |
| Electrostatic Discharge (IEC 61000-4-2) | Level 3 Criteria A1) Air Discharge: 8kV Contact Discharge: 6kV |
| Radiated Field (IEC 61000-4-3) | Level 3 Criteria A1) 80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation 1.4GHz-2GHz, 3V/M with 1kHz tone / 80% modulation 2GHz-2.7GHz, 1V/M with 1kHz tone / 80% modulation |
| Electrical Fast Transient / Burst (IEC 61000-4-4) | Level 3 Criteria A1) 2kV |
| Surge (IEC 61000-4-5) | Level 4 Criteria A1) Common Mode3): 4kV Differential Mode4): 2kV |
| Conducted (IEC 61000-4-6) | Level 3 Criteria A1) 150kHz-80MHz, 10Vrms |
| Power Frequency Magnetic Fields (IEC 61000-4-8) | Criteria A1) 30A/Meter |
| Voltage Dips and Interruptions (IEC 61000-4-11) | 0% of 100Vac, 20ms Criteria A1) |
| 40% of 100Vac, 200ms | Criteria B2) |
| 70% of 100Vac, 500ms | Criteria A1) |
| 0% of 100Vac, 5000ms | Criteria B2) |
| 0% of 240Vac, 20ms | Criteria A1) |
| 40% of 240Vac, 200ms | Criteria B2) |
| 70% of 240Vac, 500ms | Criteria A1) |
| 0% of 240Vac, 5000ms | Criteria B2) |
| Low Energy Pulse Test (Ring Wave) (IEC 61000-4-12) | Level 3 Criteria A1) Common Mode3): 2kV Differential Mode4): 1kV |
| Harmonic Current Emission | IEC/EN 61000-3-2, Class A |
| Voltage Fluctuation and Flicker | IEC/EN 61000-3-3 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Temporary degradation or loss of function which is self-recoverable 3) Asymmetrical: Common mode (Line to earth) 4) Symmetrical: Differential mode (Line to line) PMH Panel Mount Power Supply 12V 100W 1 Phase / PMH-12V100WCL□ Block Diagram Device Descriptions PMH-12V100WCLV: Front Face PMH-12V100WCLT: Harness |
| 1) | Connector Type Output isolated to PE |
| 2) | DC voltage adjustment potentiometer |
| 3) | DC OK control LED (Green) PMH Panel Mount Power Supply 12V 100W 1 Phase / PMH-12V100WCL□ Dimensions L x W x H: 129 x 97 x 30 mm (5.08 x 3.82 x 1.18 inch) (PMH-12V100WCLS: Terminal Block) Engineering Data |
| Output Load De-rating VS Surrounding Air Temperature | Note |