| Série | CliQ M DC-UPS Modules |
| Modelo | DRU-24V10AMN |
| Tipo | Acessórios |
| Marca | DELTA |
| Nominal Battery Voltage | 24 Vdc, SLA Sealed lead acid battery 2 x 12 Vdc, SLA Sealed lead acid battery in series |
| Battery Discharging Voltage Range | 21 Vdc ... 27.6 Vdc 30 Vdc Max (the maximum voltage that will not cause damage to the unit) |
| Output Voltage Range (Battery Operation) | Vout = VBattery - 0.5 Vdc |
| Battery Capacity*3 | 3.4 AH ~ 100 AH Battery Charging Current*4 0.5 A, 1 A, 1.5 A, 2 A (typ.) 0.75 A, 1.5 A, 2.25 A, 3 A (typ.) 1 A, 2 A, 3 A, 4 A (typ.) |
| (constant current) ((constant current)) | (constant current) |
| Scale (Charging) | Scale Charging Scale Charging |
| (White Switch) (Current) | (White Switch) Current (White Switch) Current |
| 0 (0.5A) | 0 0.75A 0 1A |
| 1 (1A) | 1 1.5A 1 2A |
| 2 (1.5A) | 2 2.25A 2 3A |
| 3 (2A) | 3 3A 3 4A |
| Charging Time (< 9 hr ± 1 hr) | < 6 hr ± 1 hr < 4.5 hr ± 1 hr (2 A charging current for (3 A charging current for (4 A charging current for |
| 24 V/12 AH battery) (24 V/12 AH battery)) | 24 V/12 AH battery) |
| Buffering Time | 15s, 30s, 45s, 1m, 3m, 5m, 10m, 20m, 30m, ∞ Scale Buffering Time (Blue Switch) |
| End-of-Charge Voltage | 27.6 V |
| Battery Current Consumption*5 | < 200 mA & CSB: GP1272F2. *4 The charging current can be adjusted with a four-step rotary selector switch, which will automatically de-rate when Vin < 24 Vdc. *5 Iout = 0 A and without battery charge CliQ M DC-UPS Module DRU-24VAMN Reference Buffering Time 16,000 |
| Current (7.2 AH) | 12 AH 12,000 |
| 2.5 A (6,500 s) | 14,500 s Buffering Time (s) 10,000 |
| 5A (3,000 s) | 7,000 s 8,000 |
| 10 A (1,200 s) | 2,400 s 6,000 |
| 20 A (400 s) | 1,100 s 4,000 |
| 30 A (120 s) | 450 s 2,000 |
| 40 A (25 s) | 200 s |
| 2.5 5.0 (10.0) | 20.0 30.0 40.0 Output Current (A) |
| 7.2 AH | 12 AH |
| Fig. 1 | Buffering Time VS. Output Current Mechanical |
| Case Cover / Chassis | Aluminium Dimensions (H x W x D) 124 x 38 x 117 mm 124 x 50 x 117 mm |
| (4.88 x 1.50 x 4.61 inch) | (4.88 x 1.97 x 4.61 inch) |
| Unit Weight (0.52 kg (1.15 lb)) | 0.53 kg (1.17 lb) 0.66 kg (1.46 lb) |
| Cooling System | Convection |
| Terminal (Input / Output) | 4 Pins (CN202) |
| Battery | 2 Pins (CN203) |
| Signal | 8 Pins (CN101) |
| Temperature | 4 Pins |
| Sensor & | Power Supply Header: CVILUX CP3504P1H00-NH |
| Rx/Tx*6 | Mating Connector: CVILUX CP3504S0010 |
| (CN206) | Terminal: CVILUX CP35TN21PES |
| Wire (Input / Output) | AWG 18-8 (Load: 0-5 A) AWG 14-8 (Load: 0-10 A) AWG 10-6 (Load: 0-20 A) |
| Battery (AWG 14-8 (Load: 5-10 A)) | AWG 10-8 (Load: 10-20 A) AWG 8-6 (Load: 20-40 A) |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Noise (1 Meter from power supply) | Sound Pressure Level (SPL) < 40 dBA *6 The Rx/Tx function can only be used with the Delta battery module (DRN-24V7AAEN). CliQ M DC-UPS Module DRU-24VAMN Environment |
| Surrounding Air (Operating) | -40°C to +70°C Temperature |
| Storage | -40°C to +85°C |
| Output Power (Temperature) | > 60°C de-rate power by 2.5% / °C (battery is fully charged) |
| De-rating*7 (Normal) | If the battery is not fully charged at max load, it is recommended that the surrounding air |
| Operation | temperature should not exceed 50°C. |
| Umidade de operação | 5 to 95% RH (Non-Condensing) |
| Operating Altitude | 0 to 6,000 m (Approvals apply only up to 5,000 m) |
| Shock Test (Non-Operating) | IEC 60068-2-27, 30 G (300 m/s²) for a duration of 18 ms, 1 time per direction, 2 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, 10 Hz to 500 Hz @ 30 m/s² (3 G peak); 60 min per axis for all X, Y, Z direction |
| Operating | EN 60068-2-64 Wind Power Application CliQ M DC-UPS Module DRU-24VAMN Protections |
| Overload / Overcurrent | Normal Auto Recovery |
| / Short (at system) | Operation Battery Latch off Operation |
| Over Temperature | Normal Auto Recovery Operation Battery Latch off Operation |
| Overvoltage | Auto Recovery |
| Insufficient Input Voltage Protection | Yes |
| Input Polarity Protection | Yes |
| Battery Polarity Protection | Yes |
| Wrong Battery Voltage Protection | Yes, 30 Vdc Max (the maximum voltage that will not cause damage to the unit) |
| Battery Temperature | Normal Battery surrounding air temperature < 0°C or > 40°C, DC-UPS will stop charging to protect |