| Series | LMS1300-P12B |
| Model | CE/CCC LMS1300-P12B |
| Brand | MORNSUN |
| Input Voltage Range (AC) | 90–140 VAC |
| Input Voltage Range (DC) | 180–320 VDC |
| Input Voltage Frequency | AC input: 47–63 Hz; 10% load: 89 Hz; TA=25℃, 20% load: 90 Hz |
| Efficiency | Vin: 230VAC/50Hz: %; without Fan 50% load: 94%; 100% load: 91%; V =100Vac/60Hz P =1000W: 12%; in out: % |
| Input Current | V =200Vac/50Hz P =1300W: 8A max; in out: A |
| Inrush Current (Cold Start) | V =264Vac/50Hz P =1300W: 35A max |
| Leakage Current | V =264Vac f =50Hz: 0.875mA max; in in: mA; Io=10% Load @ Vin=230Vac/50Hz: 0.90mA; Io=20% Load @ Vin=230Vac/50Hz: 0.96mA |
| Power Factor | Io=50% Load @ Vin=230Vac/50Hz: 0.98; Io=100% Load @ Vin=230Vac/50Hz: 0.99; 5%<Io≤10% Load @ Vin=230Vac/50Hz: 20; 10%<Io< 20% Load @ Vin=230Vac/50Hz: 15 |
| ITHD | %; Io≥20% Load @ Vin=230Vac/50Hz: 10%; Io≥40% Load @ Vin=230Vac/50Hz: 8%; Io≥50% Load @ Vin=230Vac/50Hz: 5% |
| Isolation Test | Input - Electric strength test for 1min., leakage current <5mA: 1500 VAC; Input - Output * Electric strength test for 1min., leakage current <10mA: 3000 VAC; Input - Ambient temperature: 25 ± 5℃: VAC |
| Insulation Operating Temperature | Relative humidity: < 95%RH, no condensation: 50 MΩ; -5 to 55℃ (Resistance Input - Output; Test voltage: 500VDC) |
| Storage Temperature | -40–70℃ |
| Operating Humidity | 90 %RH; Non-condensing: %RH |
| Storage Humidity | 95 %RH |
| Operating Altitude | 5000 m |
| Storage Ambient Height | 15200; voltage cannot exceed the dynamic +12V: 11.6–12.8 (1. 0.5m/s≤speed≤1m/s, the backplane; specification of the power module during) |
| Hot-plug | V; 2. Add 1000uF capacitive load at the +12VSB: 11.4–12.8; GB4943.1 safety approved & EN62368-1, BS (hot-plug process.; output.) |
| Safety Standards | EN62368-1;; Design refer to UL/IEC62368-1 (Rated input, 100% load @ 25℃ Evaluated by Telcordia) |
| MTBF | >500,000 h (SR-332) |
| Warranty | 5 years |
| EMC Emissions | CE: CISPR32/EN55032 CLASS A; RE: CISPR32/EN55032 CLASS A |
| EMC Immunity | Harmonic current: IEC/EN61000-3-2 (perf. Criteria A); ESD: IEC/EN 61000-4-2 Contact ±8KV/Air ±15KV (perf. Criteria A); RS: IEC/EN 61000-4-3 10V/m (perf. Criteria A); ; Surge: IEC/EN 61000-4-5 line to line ±1KV/line to ground ±2KV (perf. Criteria A); CS: IEC/EN61000-4-6 3Vrms (perf. Criteria A); Voltage dips,: interruption IEC/EN61000-4-11 >95% dip 0.5 periods (perf. Criteria A) |