| Série | LO30-20BxxMU |
| Modelo | LO30-20B19MU |
| Marca | MORNSUN |
| Faixa de tensão de entrada (CA) | 80–264 VAC |
| Faixa de tensão de entrada (CC) | 100–370 VDC |
| Input Frequency | 47–63 Hz; 115VAC: 1.0 Hz |
| Corrente de entrada | 230VAC: 0.5A max; 115VAC: 30A max |
| Corrente de partida | 60A max @230VAC |
| Corrente de fuga | 75uA typ, Max. max @240VAC |
| Conexão a quente | Unavailable |
| Precisão da tensão de saída | Other output: ±2.0%; %; 24V/36V: ±1.0% (0% - 100% load) |
| Regulação de linha | ±0.5% (Rated load) |
| Regulação de carga | ±1.0% @230VAC |
| Ondulação e ruído | 5V output: 80mV max; mV; Other output: 100mV max; 5V/12V/15V output: 0.10mV typ, 0.15mV max (20MHz bandwidth; (peak-to-peak value)) |
| Stand-by Power Consumption | W; 19V/24V/36V output: 0.20W typ, 0.25W max |
| Coeficiente de temperatura | ±0.03%/°C |
| Proteção contra curto-circuito | Hiccup, continuous, self-recover |
| Proteção contra sobrecorrente | ≥115%Io, typ, self-recover max; 5VDC output: ≤7V; 12VDC output: ≤16V; 15VDC output: ≤22V |
| Proteção contra sobretensão | Output voltage hiccup; 19VDC output: ≤28V hiccup; 24VDC output: ≤32.4V hiccup; 36VDC output: ≤42.4V hiccup |
| Minimum Load | 0%; 115VAC input: 16% |
| Tempo de retenção | ms; 230VAC input: 30 ms |
| Isolamento | VAC (Electric Strength Test for 1min.,) |
| Isolamento (entrada–saída) | 4000 VAC |
| Resistência de isolamento | Input - output 500VDC: 100 MΩ |
| Temperatura de operação | -30 to +85℃ |
| Temperatura de armazenamento | -40–+85℃ |
| Umidade de armazenamento | 95 %RH |
| Altitude | 5000 m; +50℃ to +70℃ Other output: 2.50; +50℃ to +70℃ 24V/36V: 1.00 %/℃ |
| Power Derating | +70℃ to +85℃ Other output: 1.35 %/VAC; +70℃ to +85℃ 24V/36V: 3.33 %/VAC; 80VAC - 100VAC: 1.00 %/VAC; Clearance: 7.4 %/VAC |
| Safety Distance | mm; Creepage: 8.0 mm; EN62368-1, BS EN62368-1 (Report); mm; Design refer to IEC/EN60601-1, mm; version), typ, ES60601-1 (3.1 min mm; CAN/CSA-C22.2–3, mm |
| Safety Standard | Edition 4; typ; EN60601-1-2 min; IEC62368-1; EN/IEC60335-1; EN61558-1; GB4943.1 |
| Classe de segurança | CLASS I I |
| MTBF | MIL-HDBK-217F@25℃>300,000 h |
| Dimension | 76.20 x 50.80 x 24.00 mm (Substrate + Plug-in height, see the external dimension drawing for details) |
| Peso | 80g (Typ.) |
| Cooling method | Free air convection |
| Emissões EMC | CE: CISPR32/EN55032/EN55011 CLASS B; RE: CISPR32/EN55032/EN55011 CLASS B |
| Imunidade EMC | Harmonic: current IEC/EN61000-3-2 CLASS A; ESD: IEC/EN61000-4-2 Contact ±8KV/Air ±15KV (Perf. Criteria A); RS: IEC/EN61000-4-3 10V/m (Perf. Criteria A); EFT: IEC/EN61000-4-4 ±2KV (Perf. Criteria A); ; CS: IEC/EN61000-4-6 10Vr.m.s (Perf. Criteria A); Voltage dips,: short interruption IEC/EN61000-4-11 100% dip 1 periods, 30% dip 25 periods,100% |