| Serie | ADP |
| Modell | ADP-100XB BD |
| Typ | Ladegeräte und Adapter |
| Marke | DELTA |
| Surrounding Temperature (Operating) | 0°C to +35°C |
| Storage | -30°C to +80°C |
| Power De-Rating | N/A |
| Betriebsfeuchtigkeit | 5%-90% RH (non-condensing) |
| Operating Altitude | 5000 meters (16400 feet) Test height 130 cm, 1 sample 1 time, Steel Ball 540 g, Concrete |
| Ball Impact Test | Floor Test height 130 cm, 6 face for each sample, concrete floor |
| Drop Test | Function test pass after drop test |
| Shock Test (Non-Operating) | 50 G, 11 ms, 1 shock for each direction |
| Vibration (Non-Operating) | 5-500 Hz, 2.09 Grms, 20 mins, one cycle for each three axis Protections <7.5V @ 5V ; <11.7V @ 9V ; <15.6V @ 12V ; Overvoltage (max) <19.5V @ 15V ; <26V @ 20V, Latch mode 3.3~3.9A @ 5V ; 3.3~3.9A @ 9V ; 3.3~3.9A @ 12V ; Overload / Overcurrent (max) 3.3~3.9A @ 15V ; 5.3~6.5A @ 20V, Latch mode |
| Over Temperature | Latch mode |
| Kurzschluss | Latch mode |
| Protection Against Shock | Class I Reliability Data > 100,000 hrs. MTBF at Input: 115 Vac, Output: 100% load, Ta: 25°C |
| Expected Cap Life Time @ 25°C | 8760hours (100% load, 115Vac) |
| Case Temperature Rise | < 50°C @ 100/240Vac, Output: 100% load, Ta: 25°C TECHINCAL DATASHEET AC-DC Adapter PD 100 W / ADP-100XB B Safety Standards / Directives |
| Electrical Safety | IEC/EN 62368-1, 60950 BSMI CNS 13438, 14336-1, 15663 PSE J62368-1, J55032, J3000 UL 62368-1, CSA 62368-1 PSB IEC 62368-1:2014, 60950-1:2005+A1:2009+A2:2013 CCC GB 4943.1 TUV BS EN/EN 62368-1 EAC TP TC 004 Comply with EMC Directive 2014/30/EU, the Low Voltage Directive |
| CE/UKCA | 2014/35/EU, RoHS Directive 2011/65/EU+ (EU) 2020/659 and Commission Regulation (EU) 2019/1782, ErP Directive |
| Galvanic Isolation (I/P to O/P) | 3000 Vac EMC |
| EMC / Emissions (EN 55032) | Criteria Class B |
| Harmonic Current Emissions (IEC 61000-3-2) | The power consumption of EUT is less than 75W and no limits apply |
| Voltage Flicker | IEC 61000-3-3 |
| Electrostatic Discharge (IEC 61000-4-2) | Air Discharge performance criterion A: ±15 kV, no damage Contact Discharge performance criterion A: ±8 kV, no damage |
| Radio Frequency Electromagnetic Field (IEC 61000-4-3) | Criteria A 80 MHz – 1 GHz, 3 V/m, 80% AM (1 KHz) |
| Electrical Fast Transient (IEC 61000-4-4) | Level 3 Criteria C |
| Surge (IEC 61000-4-5) | Level 3 Criteria A Common Mode: ±2 kV Differential Mode: ±1 kV |
| Radio Frequency Common Mode (IEC 61000-4-6) | Criteria A 150 kHz – 10 MHz, 3 V, 80% AM (1 KHz) 10 MHz – 30 MHz, 3V-1V, 80% AM (1 KHz) 30 MHz – 80 MHz, 1V, 80% AM (1 KHz) |
| Power Frequency Magnetic Fields (IEC 61000-4-8) | Criteria A 1 A/m, 50Hz |
| Voltage Dips (IEC 61000-4-11) | Voltage dips 70% residual voltage, 25 periods (Criterion C) < 5% residual voltage, 0.5 periods (Criterion B) Voltage short interruptions < 5% residual voltage, 250 periods (Criterion C) 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restore to normal operation after test. 3) Criteria C: PSU shuts down during test, but need operator to reset. |
| The Netherlands | United Kingdom |
| Delta Greentech (Netherlands) B.V. | Delta Electronics Europe Limited |
| Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands | 1 Redwood Court, Peel Park Campus, East Kilbride, Glasgow, G74 5PF, United Kingdom |