| السلسلة | PMT2 ECO (High Line) |
| الطراز | PMT-24V100W2BNJ |
| النوع | مزودات طاقة تبديلية مغلقة |
| العلامة التجارية | DELTA |
| Case Chassis | Aluminum |
| Case Cover | SGCC |
| Dimensions (L x W x H) | 129 x 97 x 30 mm (5.08 x 3.82 x 1.18 inch) |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Terminal | M3.5 x 7 Pins (Rated 300 V / 20 A) |
| Wire | AWG 18-12 Current rating can refer to page 6 “Wire AWG Table” |
| Noise (1 Meter from power supply) | Sound Pressure Level (SPL) < 25 dBA Environment |
| Surrounding Air Temperature (Operating) | -40°C to +70°C |
| Storage | -40°C to +85°C |
| Power De-rating | > 50°C de-rate power by 2% / °C |
| رطوبة التشغيل | 20 to 90% RH (Non-Condensing) |
| Operating Altitude | 0 to 5,000 Meters (0 to 16,400 ft) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11 ms, 3 shocks for each 3 directions |
| Operating | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11 ms, 3 shock for each 3 directions. |
| Vibration (Non-Operating) | IEC 60068-2-6, Random: 5 Hz to 500 Hz (2.09G); 20 min per axis for all X, Y, Z direction |
| Over Voltage Category | II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) Protections |
| Overvoltage (26.4 V - 33.6 V) | 52.8 V - 64.8 V |
| SELV Output, Latch Mode | SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto- Recovery) |
| Over Temperature | Latch Mode |
| قصر الدائرة | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Protection Against Shock | Class I with PE*3 connection *3 PE: Protection Earth PMT2 ECO Panel Mount Power Supply PMT2 ECO 100 W series / PMT-□V100W2BNJ Reliability Data |
| MTBF | > 700,000 hrs as per Telcordia SR-332 (I/P: 230 Vac, O/P: 100% Load, Ta: 25°C) |
| Expected Cap Life Time | 10 years (230 Vac, 50% load @ 40°C) Safety Standards / Directives |
| Safety Entry Low Voltage | SELV |
| Electrical Safety (CB scheme) | IEC 62368-1 |
| CCC | GB 4943.1 |
| BIS | IS 13252(Part 1) |
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation (Input to Output) | 4.0 KVac |
| Input to Ground | 2.0 KVac |
| Output to Ground | 1.25 KVac EMC |
| Emissions (CE & RE) | CISPR 32, EN 55032, Class A |
| Immunity | EN 55035 |
| Electrostatic Discharge (IEC 61000-4-2) | Level 4 Criteria A1) Air Discharge: 15 kV Contact Discharge: 8 kV |
| Radiated Field (IEC 61000-4-3) | Level 3 Criteria A1) 80 MHz - 1 GHz, 10 V/M with 1 kHz tone / 80% modulation |
| Electrical Fast Transient / Burst (IEC 61000-4-4) | Level 3 Criteria A1) 2 kV |
| Surge (IEC 61000-4-5) | Level 4 Criteria A1) Common Mode4): 4 kV Differential Mode5): 2 kV |
| Conducted (IEC 61000-4-6) | Level 3 Criteria A1) 150 kHz-80 MHz, 10 Vrms |
| Power Frequency Magnetic (IEC 61000-4-8) | Level 4 Criteria A1) |
| Fields | 30 A/Meter |
| Voltage Dips and Interruptions (IEC 61000-4-11) | 0% residual; 1 cycle, Criteria B 40% residual; 10 cycle, Criteria C3) 70% residual; 25 cycle, Criteria C3) |
| Harmonic Current Emission (IEC/EN 61000-3-2) | Class A 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test. 3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test) 4) Asymmetrical: Common mode (Line to earth) 5) Symmetrical: Differential mode (Line to line) |
| 1) | Input & Output terminal block connector |
| 2) | DC voltage adjustment potentiometer |
| 3) | DC OK control LED (Green) PMT2 ECO Panel Mount Power Supply PMT2 ECO 100 W series / PMT-□V100W2BNJ Dimensions L x W x H: 129 x 97 x 30 mm (5.08 x 3.82 x 1.18 inch) Wire AWG Table Current rating for PVC Wire AWG |
| 6 AWG (52.5 A) | 20 AWG 6.5 A |
| 8 AWG (37.5 A) | 22 AWG 5.0 A |
| 10 AWG (29.0 A) | 24 AWG 3.5 A |
| 12 AWG (22.5 A) | 26 AWG 2.5 A |
| 14 AWG (16.5 A) | 28 AWG 2.0 A |
| 16 AWG (12.0 A) | 30 AWG 1.5 A |
| 18 AWG | 9.0 A PMT2 ECO Panel Mount Power Supply PMT2 ECO 100 W series / PMT-□V100W2BNJ Engineering Data |
| Output Load De-rating VS Surrounding Air Temperature | Note |
| 70 (3.) | If the output capacity is not reduced when the device will run into Over Temperature is lowered or the load is reduced as far as necessary to keep the device in working |
| 4. | In order for the device to function in the |
| -40 (-30) | -20 -10 0 10 20 30 40 50 60 70 a safety distance as recommended in the |
| Surrounding Air Temperature (oC) | safety instructions while the device is in operation. |
| Fig. 1 | 5. Depending on the surrounding air temperature |