| Série | ADT |
| Modèle | ADT-060A12AA |
| Type | Chargeurs et adaptateurs |
| Marque | DELTA |
| Nominal Output Voltage (12 Vdc) | 15 Vdc 19 Vdc 24 Vdc |
| Rated Output Current (5A) | 4A 3.2A 2.5 A |
| Output Power (60 W) | 60 W 60.8 W 60 W |
| Régulation secteur | ± 1% |
| Load Regulation (± 5.0%) | ± 4.0% ± 3.0% ± 2.5% |
| Combine Regulation (± 8.0%) | ± 7.0% ± 5.0% ± 5.0% |
| PARD* (20MHz) (0°C to 40°C) | < 240 mVpp < 300 mVpp < 380 mVpp < 480 mVpp |
| -10°C to 0°C (< 480 mVpp) | < 600 mVpp < 760 mVpp < 960 mVpp |
| Rise Time (115 Vac) | 30 mS (typ.) 230 Vac |
| Start-up Time (115 Vac) | 1000 ms (typ.) |
| 230 Vac | 500 ms (typ.) |
| Hold-up Time (115 Vac) | 12 ms (typ.) |
| Capacitive load (max) | 470 uF *PARD is measured with an AC coupling mode, and in parallel with 0.1µF ceramic capacitor & 22µF electrolytic capacitor. Mechanical |
| Case | PC |
| Dimensions (W x L x H) | 46.0 x 108.0 x 29.5 mm (1.81 x 4.25 x 1.16 inch) |
| Cooling System | Convection |
| Output Cable (Length: 1200 mm) | #16AWG ADT-060A12AA B / ADT-060A12AB B |
| Specification | UL1571 |
| #18AWG | ADT-060A15AA B / ADT-060A15AB B |
| #20AWG | ADT-060A19AA B / ADT-060A19AB B ADT-060A24AA B / ADT-060A24AB B |
| Input Socket (C6) | ADT-060A12AA B ADT-060A15AA B ADT-060A19AA B ADT-060A24AA B |
| C8 | ADT-060A12AB B ADT-060A15AB B ADT-060A19AB B ADT-060A24AB B TECHINCAL DATASHEET AC-DC Adapter Environment |
| Surrounding Air (Operating) | -10°C to +60°C |
| Temperature | (-20°C cold start @ 100% Load) |
| Storage | -40°C to +85°C |
| Power De-rating | > 40°C de-rating power by 2.5% / °C < 90Vac de-rating power by 2% / V |
| Humidité de fonctionnement | 5 to 95% RH (Non-Condensing) |
| Humidité de stockage | 5 to 95% RH (Non-Condensing) |
| Operating Altitude | Up to 5,000 meters (up to 16,400 feet) |
| Ball Impact Test | Test height 130 cm, 1 sample 1 time, Steel Ball 500 g, Concrete floor Test height 100 cm, 6 face for each sample, concrete floor |
| Drop Test | Function test pass after drop test |
| Shock Test (Non-Operating) | Half sine wave, 50 G, 11 ms, 1 shocks for each direction, 6 direction |
| Vibration (Non-Operating) | 5-500 Hz, 2.09 Grms, 20 minute for X,Y,Z axis Protections |
| Overvoltage (13.2-18.0 V,) | 16.5-22.5 V, 20.9-28.5 V, 26.4-36.0 V, |
| Latch Mode (Latch Mode) | Latch Mode Latch Mode |
| 5.25-10.00 A (4.20-8.00 A) | 3.36-6.40 A 2.625-5.00 A Overload / Overcurrent Auto-Recovery when the fault is removed |
| Over Temperature | Latch Mode |
| Court-circuit | Auto-Recovery when the fault is removed |
| Protection Against Shock | ADT-060A12AA B ADT-060A15AA B ADT-060A19AA B ADT-060A24AA B Class II ADT-060A12AB B ADT-060A15AB B ADT-060A19AB B ADT-060A24AB B Reliability Data |
| MTBF | > 700,000 hrs. per Telcordia SR-332 at Input: 115 Vac, Output: 100% load, Ta: 25°C |
| Expected Cap Life Time | 5 years (50% load @ 25°C) TECHINCAL DATASHEET AC-DC Adapter Safety Standards / Directives |
| Electrical Safety (CB scheme) | IEC/UL/EN 60950-1; IEC/UL/EN 62368-1 |
| BSMI | CNS 14336-1 |
| CCC | GB 4943.1-2011 |
| PSE | J 60950-1(H29) |
| KC | K 60950-1 |
| Limited Power Source (CB scheme) | IEC 62368-1 (LPS) |
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016 |
| Galvanic Isolation (Input to Output) | 3000 Vac EMC |
| Emissions (CE & RE) | CISPR/EN/BS EN 55032 Class B BSMI CNS 13438 FCC Part 15, ICES-003, ANSI C63.4 GB/T9254- 2008 KN32 |
| Immunity | EN/BS EN 55024; KN35 |
| Radiated and | Conducted Emissions: EN/BS EN 55032 Class B |
| Conducted Emissions | Radiated Emissions: EN/BS EN 55032 Class B |
| Flicker and Voltage | IEC 61000-3-3 Fluctuation |
| Harmonic Current (IEC 61000-3-2) | Class D; GB 17625.1-2003 Emissions |
| Electrostatic (IEC 61000-4-2) | Criteria A1) |
| Discharge Standard | Air Discharge: 15 kV Contact Discharge: 8 kV |
| Radiated Field (IEC 61000-4-3) | Level 2 Criteria A1) |
| Immunity Test | 80 MHz – 1 GHz, 3 V/M with 1 kHz tone / 80% modulation. |