| Dòng sản phẩm | PMT2 |
| Mã hàng | PMT-12V100W2BA |
| Loại | Bộ nguồn chuyển đổi loại kín |
| Thương hiệu | DELTA |
| Case Chassis | Aluminum |
| Case Cover | SGCC |
| Dimensions (L x W x H) | 129 x 97 x 30 mm (5.08 x 3.82 x 1.18 inch) |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Terminal | M3.5 x 7 Pins (Rated 300 V / 20 A) |
| Wire | AWG 18-12 Current rating can refer to page 6 “Wire AWG Table” |
| Noise (1 Meter from power supply) | Sound Pressure Level (SPL) < 25 dBA Environment |
| Surrounding Air Temperature (Operating) | -30°C to +70°C ( -40°C Cold Start) |
| Storage | -40°C to +85°C |
| Power De-rating | > 50°C de-rate power by 2% / °C < 115 Vac de-rate power by 0.6% / V (85% load @ 90 Vac) |
| Độ ẩm hoạt động | 20 to 90% RH (Non-Condensing) |
| Operating Altitude | 0 to 5,000 Meters (0 to 16,400 ft) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11 ms, 3 shocks for each 3 directions |
| Operating | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11 ms, 3 shock for each 3 directions. |
| Vibration (Non-Operating) | IEC 60068-2-6, Random: 5 Hz to 500 Hz (2.09G); 20 min per axis for all X, Y, Z direction |
| Over Voltage Category | II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) Protections |
| Overvoltage (13.2 V - 17.4 V) | 16.5 V - 21.0 V 26.4 V - 33.6 V 33.0 V - 40.5 V 39.6 V - 48.6 V 52.8 V - 64.8 V |
| SELV Output, (SELV Output,) | SELV Output, SELV Output, SELV Output, SELV Output, |
| Latch Mode (Latch Mode) | Latch Mode Latch Mode Latch Mode Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Ngắn mạch | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Protection Against Shock | Class I with PE*4 connection *4 PE: Protection Earth Reliability Data |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230 Vac, O/P: 100% Load, Ta: 25°C) |
| Expected Cap Life Time | 10 years (230 Vac, 50% load @ 40°C) PMT2 Panel Mount Power Supply PMT2 100 W series / PMT-□V100W2B□□ Safety Standards / Directives |
| Safety Entry Low Voltage | SELV |
| Electrical Safety (TUV Bauart) | EN 62368-1, EN60335-1, EN 61558-1/-2-16 |
| cULus | UL 62368-1 and CAN/CSA C22.2 No. 62368-1 |
| CB scheme | IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16 |
| KC | K 60950-1 |
| EAC | TP TC 004/2011 |
| BSMI | CNS 14336-1 |
| BIS | IS 13252 (Part 1) |
| CCC | GB 4943.1 |
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016 |
| Galvanic Isolation (Input to Output) | 4.0 KVac |
| Input to Ground | 2.0 KVac |
| Output to Ground | 1.25 KVac EMC |
| Emissions (CE & RE) | CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR32 Compliance to EN/BS EN 55014-1, FCC Title 47, EN/BS EN 61000-6-3 : Class B |
| Immunity | EN/BS EN 55035, KN35, EN/BS EN 61000-6-2 Compliance to EN/BS EN 55014-2,EN/BS EN 61000-6-1 |
| Electrostatic Discharge (IEC 61000-4-2) | Level 4 Criteria A1) Air Discharge: 15 kV Contact Discharge: 8 kV |
| Radiated Field (IEC 61000-4-3) | Level 3 Criteria A1) 80 MHz - 1 GHz, 10 V/M with 1 kHz tone / 80% modulation |
| Electrical Fast Transient / Burst (IEC 61000-4-4) | Level 3 Criteria A1) 2 kV |
| Surge (IEC 61000-4-5) | Level 4 Criteria A1) Common Mode4): 4 kV Differential Mode5): 2 kV |
| Conducted (IEC 61000-4-6) | Level 3 Criteria A1) 150 kHz-80 MHz, 10 Vrms |
| Power Frequency Magnetic (IEC 61000-4-8) | Level 4 Criteria A1) |
| Fields | 30 A/Meter |
| Voltage Dips and Interruptions (IEC 61000-4-11) | 0% residual; 1 cycle, Criteria B 40% residual; 10 cycle, Criteria C3) 70% residual; 25 cycle, Criteria C3) |
| Harmonic Current Emission (IEC/EN/BS EN) | Class A 61000-3-2 |
| Voltage Sag Immunity SEMI (80% of 200 Vac) | 160 Vac, 1000 ms Criteria A1) |
| F47 – 0706 (70% of 200 Vac) | 140 Vac, 500 ms Criteria A1) |
| 50% of 200 Vac (100 Vac, 200 ms) | Criteria A1) 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test. 3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test) 4) Asymmetrical: Common mode (Line to earth) 5) Symmetrical: Differential mode (Line to line) |
| L (AC/DC Converter) | Vo+ |
| & Inrush current (DC/DC) | Output Rectifier |
| EMI Filter (Converter) | DC Output |
| limit | Filter & Filter |
| N | Vo- |
| Over Temperature (PWM Control &) | Photo Coupler & |