| Série | URA_LD-20WR3 |
| Modelo | URB2424LD-20WR3 |
| Tipo | Conversores DC/DC |
| Marca | MORNSUN |
| Corrente de entrada (plena carga / sem carga) | 3.3V output: 799/40 typ, 818/45 max mA; 24VDC input 5V output: 969/40 typ, 993/80 max mA; Others: 947/6 typ, 969/10 max mA; 3.3V output: 400/20 typ, 409/25 max mA; 48VDC input 5V output: 485/20 typ, 497/60 max mA; Others: 474/5 typ, 485/9 max mA; 24VDC input: 30mA |
| Corrente de ondulação refletida | 48VDC input: 30; 24VDC input: -0.7–50 |
| Tensão de surto (máx. 1 s) | 48VDC input: -0.7–100; 24VDC input: 9 |
| Start-up Voltage | VDC; 48VDC input: 18 VDC; 24VDC input: 6.5 VDC typ, 5.5 VDC min |
| Input Under-voltage Protection | 15.5 typ, 12 min @48VDC input |
| Start-up Time | 10 ms (Nominal input & constant resistance load) |
| Filtro de entrada | Pi filter (3.5-12VDC); Module on: Ctrl pin open or pulled high (3.5-12VDC) |
| Ctrl | Module off: Ctrl pin pulled low to GND (0-1.2VDC); Input current when off: 4mA typ, 7mA max |
| Conexão a quente | Unavailable |
| Voltage Accuracy ① | ±1 typ, ±3 max; Input voltage variation from low Positive Output: ±0.2 typ, ±0.5 max (0%-100% load) |
| Regulação linear | to high at full load Negative Output: ±0.5% typ, ±1% max; Positive Output: ±0.5% typ, ±1% max |
| Load Regulation ② | ±0.5 typ, ±1.5 max (Negative Output) (5%-100% load; Dual output with Positive output at 50% load and) |
| Cross Regulation | ±5% (0%-100% load; Negative output from 1) |
| Transient Recovery Time | 300 µs typ, 500 µs max; 25% load step change,: µs; 3.3V/5V/±5V output: ±5 µs typ, ±8 µs max |
| Transient Response Deviation | nominal input voltage: %; Others: ±3% typ, ±5% max |
| Coeficiente de temperatura | ±0.03%/℃ (Full load) |
| Ripple & Noise ③ | 50mVp-p typ, 100mVp-p max (5%-100% load) (20MHz bandwidth) |
| Trim | 90–110 %Vo |
| Proteção contra sobretensão | 110–160 %Vo (Input voltage range) |
| Proteção contra sobrecorrente | 110–190 %Io |
| Proteção contra curto-circuito | Hiccup, continuous, self-recovery |
| Isolamento (entrada–saída) | VDC (Electric Strength test for 1 minute with a leakage) |
| Isolamento | 1500 VDC |
| Resistência de isolamento | Input-output resistance at 500VDC: 1000 MΩ; Input-output capacitance at URB2424LD-20WR3: 2050 MΩ |
| Capacitância de isolamento | pF; 100kHz/0.1V Others: 1050 pF |
| Temperatura de operação | -40 to +85℃ (See Fig. 1) |
| Temperatura de armazenamento | -55–+125℃ |
| Umidade de armazenamento | 5–95 %RH (Non-condensing) |
| Case Material Aluminum | alloy |
| Horizontal | package (without heat sink): 50.80 × 25.40 × 11.80 mm |
| A2S chassis | mounting (without heat sink): 76.00 × 31.50 × 21.20 mm |
| A4S Din-rail | mounting (without heat sink): 76.00 × 31.50 × 25.80 mm |
| Without | heat sink Horizontal package/A2S chassis mounting/A4S Din-rail mounting: 25.0g/48.0g/68.0g(Typ.) |
| With heat | sink Horizontal package/A2S chassis mounting/A4S Din-rail mounting: 34.0g/56.0g/76.0g(Typ.) |
| Cooling Method Free air | convection |
| Emissões EMC | CE: CISPR32/EN55032 CLASS A (without extra components)/ CLASS B (see Fig.3-② for (recommended circuit)); RE: CISPR32/EN55032 CLASS A (without extra components)/ CLASS B (see Fig.3-② for (recommended circuit)) |
| Imunidade EMC | ESD: IEC/EN61000-4-2 Contact ±4kV (perf. Criteria B); RS: IEC/EN61000-4-3 10V/m (without extra components) (perf. Criteria A); EFT: IEC/EN61000-4-4 ±2kV (see Fig.3-① for recommended circuit) (perf. Criteria B); Surge: IEC/EN61000-4-5 line to line ±2kV (see Fig.3-①for recommended circuit) (perf. Criteria B); CS: IEC/EN61000-4-6 3 Vr.m.s (without extra components) (perf. Criteria A); |